In this study, a novel non-invasive and contactless microwave sensor using a square substrate integrated waveguide (SIW) re-entrant cavity is proposed for complex permittivity measurement of chemical solutions. The working principle of this sensor is based on cavity perturbation technique, in which the resonant properties of cavity are utilized as signatures to extract the dielectric information of liquid under test (LUT). A winding microfluidic channel is designed and embedded in the gap region of the cavity to obtain a strong interaction between the induced electric field and LUT, thus achieving a high sensitivity. Also, a mathematical predictive model which quantitatively associates the resonant properties of the sensor with the dielectric constant of LUT is developed through numerical analysis. Using this predictive model, quick and accurate extraction of the complex permittivity of LUT can be easily realized. The performance of this sensor is then experimentally validated by four pure chemicals (hexane, ethyl acetate, DMSO and water) together with a set of acetone/water mixtures in various concentrations. Experimental results demonstrate that the designed sensor is capable of characterizing the complex permittivities of various liquids with an accuracy of higher than 96.76% (compared with the theoretical values obtained by Debye relaxation equations), and it is also available for quantifying the concentration ratio of a given binary mixture.
This work presents a differential humidity sensor by longitudinally stacking the sensing and referencing substrate integrated waveguide (SIW) re-entrant cavity resonators (RECRs) for relative humidity (RH) detection. Three different technologies, such as air-filled substrate, metal grid holes (METGH) and sensitive material, are integrated to enhance the humidity sensing response. Firstly, introduction of air-filled substrate and METGH can effectively improve the flowability of the humid air, and can reduce the response time. Secondly, PEDOT:PSS is used as a humidity sensitive (HS) material and deposited in the highly concentrated E-field distribution area of sensing SIW RECR, and the modulation of the dielectric constant of HS material by humid air can achieve high humidity sensitivity. Furthermore, the proposed differential structure itself can suppress common-mode perturbations to prevent temperature cross sensitivity. Several different sensors are fabricated and a series of experiments are performed to investigate the dependence of humidity sensing response on the device structure and the deposited amount of HS material. When a specific amount of HS material is deposited in the HS area, excellent humidity sensing performances such as high sensitivity, low hysteresis and fast response can be successfully achieved. Among them, the sensor $\text{B}_{{1}}$ (300-uL HS material and with METGH) demonstrates the best humidity sensing performance in the range of 32.8% to 97.3% RH, and shows high sensitivity of 209.3 kHz/%RH and low hysteresis of 0.592% RH, and the corresponding response time is reduced to 1/6 of that without METGH. Moreover, the sensor $\text{B}_{{1}}$ has excellent suppression on the temperature variation.
In this paper, a modified substrate integrated waveguide (SIW) re-entrant microwave sensor is implemented by an annular slot loaded SIW re-entrant cavity resonator (RECR) to evaluate complex permittivity of liquid under test (LUT). The fringe electric field (E-Field) around metal post of the SIW RECR is suppressed by loading the plane disk. And then, by loading a narrow annular slot, the corresponding fringe non-linear capacitor is transferred as an annular capacitor which has linear response to real permittivity of LUT and is connected in parallel with the gap parallel plate capacitor of the RECR, and then the corresponding physical equivalent circuit model is accurately established. The dependence of the sensitivity of the proposed sensor on the dimension of the annular slot is discussed. The unique quantitative function relationship, instead of a mathematical fitted one, between the resonant frequency and the real permittivity of LUT is obtained to characterize the real permittivity predictive model by reasonably neglecting the ratio term of annular-slot capacitance to LUT effective capacitance. Additionally, an improved algorithm for more accurately extracting imaginary permittivity is proposed. A prototype of the proposed sensor is fabricated and measured. The predictive model of the complex permittivity is calibrated by using of methanol-water mixtures with known complex permittivity and is further verified by ethanol-water mixtures. The result of experiment verification, with the maximum measurement errors of real and imaginary permittivity of 4.07% and 7.79%, demonstrates that the complex permittivity of the liquid can be accurately characterized by using the proposed sensor.
23 November 2022 in IEEE Transactions on Microwave Theory and Techniques
The TE $_{201}$ and TE $_{102}$ modes of the folded substrate integrated waveguide (FSIW) rectangular cavity (RC) are used as frequency-selective elements to be coupled with a negative-resistance circuit (NRC) to implement a dual-mode negative-resistance (NR)-based voltage-controlled oscillator (VCO). Then, a wideband low-power-level signal from vector network analyzer (VNA) is injected into the NR-based VCO to implement an injection-locked-oscillation (ILO)-based dual-mode FSIW RC active sensor for separately detecting moisture and Fe particle in lubricant oil. With the help of an external static H-field, the lubricant oil passes through the shared sensing region where the strong time-harmonic H-field of TE $_{201}$ mode and the E-field of TE $_{102}$ mode are highly concentrated. Then, a LabVIEW-based real-time measurement system for ILO frequency is developed to characterize the moisture content in the volume fraction from 0.025% to 0.5% and Fe particle concentration from 40 to 200 mg/dL. The measured ILO frequency self-shift noise $\Delta f_{\mathrm{self}}$ of the TE $_{201}$ (TE $_{102})$ mode of the active sensor loaded by pure lubricant oil is 15 kHz. The ILO frequency shift $\Delta f_{{s}}$ of the dual-mode active sensor loaded by lubricant oil sample is recorded to demonstrate a high sensitivity (2.8 MHz/vol% for moisture and 5.8 kHz/mg $\cdot$ dL $^{-1}$ for Fe particle) and low limit of detection (0.025% for moisture and 40 mg/dL for Fe particle).
12 December 2022 in IEEE Transactions on Microwave Theory and Techniques
Two passive re-entrant cavity resonators (RECRs) in substrate integrated waveguide (SIW) configuration are vertically stacked to implement a miniaturized dual RECRs sensor. Only one negative resistance circuit (NRC) is innovatively proposed to be connected with these two RECRs in the common stacked metal layer between them and implement an active dual RECRs sensor, and the corresponding equivalent lumped circuit mode is proposed to analyze the dielectric sensing characteristics. Then, the compensated power obtained from the NRC is simultaneously fed into these two RECRs embedded with two microfluidics, and the $Q$ -factor of either of these two RECRs can be greatly enhanced by simply changing the bias voltages of the transistor and varactor in the NRC. Finally, the active sensor is utilized to perform high-resolution detection to glucose solutions in high concentration range from 100 to 1000 mmol/L and low concentration range from 1 to 50 mmol/L. By gradually approximating the resonant frequency self-shift noise $\Delta f_{\mathrm{Aself}}$ ( $\Delta f_{\mathrm{Bself}})$ of the active RECR-A (RECR-B) by the resonant frequency shift $\Delta f_{\mathrm{s}}$ determined by glucose solutions, minimum detectable glucose concentration of 1 mmol/L is experimentally achieved. The linear relationship between the $\Delta f_{\mathrm{s}}$ and the glucose concentration is experimentally demonstrated, and shows good potential for glucose sensing.
26 April 2021 in IEEE Microwave and Wireless Components Letters
This letter presents a miniaturized differential microfluidic sensor by longitudinally integrating two substrate integrated waveguide (SIW) re-entrant cavity resonators (RECRs) for characterization of dielectric liquid materials. The mutual coupling between these two RECRs is prevented by the stacked metal wall between them. The feedline implemented by a microstrip-to-stripline-to-SIW transformer in the stacked metal wall is proposed to excite these two RECRs simultaneously. The dependence of complex permittivity of calibrated samples on the resonance frequency shift and quality factor of the sensor is used to build a predictive model of complex permittivity of liquid. The ability of this sensor to accurately measure liquid complex permittivity is verified by practical measurements.