Vladimír Szomosi

Mr. Vladimír Szomosi

Department of Electric Power Engineering, Technical University of Košice, Košice, Košický, Slovakia
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2026 in Solar
Verified
Journal Article
Open access
PDF file
Vladimír SzomosiVladimír Szomosi
Vladimír Szomosi
SBStanislav Baňački
Stanislav Baňački
JŠJúlius Šimčák
Július Šimčák
MBMarek Bobcek
Marek Bobcek
ZČZsolt Čonka
Zsolt Čonka
ZVZoltan Varga
Zoltan Varga
Deep networks dominate photovoltaic (PV) thermographic fault detection but need large annotated datasets and resist interpretation. We present a lightweight, interpretable infrared workflow combining support-vector-machine (SVM) module/background segmentation from four handcrafted features with an adaptive grid analysis labelling regions as nominal-intensity, high-intensity anomaly or low-intensity anomaly relative to a module-internal reference; the anomaly classes are inspection candidates, not confirmed faults. Evaluation used 21 close-range images of one 20 W module—recorded with the camera’s visible-light edge fusion active, so they are fused infrared/visible frames—and all 596 of a public five-sector UAV dataset. Segmentation against manual masks reached a mean intersection-over-union of 0.64; a feature ablation shows intensity statistics dominate, and an end-to-end Otsu pipeline gives almost the same high-intensity share (4.54% versus 4.50%): the SVM contributes reproducibility—removing the manual segmentation threshold, though not the empirical +48/−60 offsets—not accuracy. High-intensity regions concentrated in the module’s lower half, co-locating with a bus-bar defect known from hardware inspection—suggestive, not validated. The single-module, image-level close-range evaluation is optimistic, and the UAV shares, from a separately trained SVM, illustrate cross-domain application only. Segmentation runs at about 15 images per second on CPU. The method is a relative-intensity thermal screening workflow, not a validated defect-diagnosis or plant-health assessment method, and applies only where acquisition is controlled and the offsets are recalibrated for the target camera and palette.

27 November 2025
Verified
Conference Paper
Closed access
Vladimír SzomosiVladimír Szomosi
Vladimír Szomosi
ZČZsolt Čonka
Zsolt Čonka
JŠJúlius Šimčák
Július Šimčák
ZBZoltan Balogh
Zoltan Balogh
This paper presents an expanded comparative analysis of the two primary hydrogen propulsion architectures for commercial aviation. Direct combustion in gas turbines and fuel cell systems. In the context of decarbonization goals, such as the Flightpath 2050 initiative published in 2011 by ACARE (Advisory Council for Aviation Research and Innovation in Europe). The targets call for $90 \%$ reduction in nitrogen oxide (NOx) emissions and a $75 \%$ reduction in carbon dioxide (CO2) compared to typical aircraft from the year 2000. Hydrogen emerges as a key vector for sustainable aviation. Direct hydrogen combustion, enhanced by advanced technologies such as “micromix” combustion, offers the potential to reduce NOx. Proton Exchange Membrane (PEM) fuel cell systems can potentially eliminate both CO2 and NOx. However, they face challenges that lead to “snowball” effect which increases the maximum takeoff mass (MTOM) by $27-40 \%$ and operating costs by approximately $30 \%$ compared to combustion variants.

29 January 2026
Verified
Conference Paper
Closed access
Vladimír SzomosiVladimír Szomosi
Vladimír Szomosi
MBMarek Bobček
Marek Bobček
JŠJúlius Šimčák
Július Šimčák
RŠRóbert Štefko
Róbert Štefko
ZČZsolt Čonka
Zsolt Čonka
The escalating integration of electric vehicles (EVs) presents a critical challenge to building energy systems and local distribution grids, introducing significant, dynamic loads. Concurrently, the aggregated battery capacity of these vehicles represents a vast, underutilized distributed energy resource. This paper addresses this duality by proposing the conceptual design of the Resilient State-Based V2B Dispatch Algorithm (RSDA). The RSDA is a novel control strategy formulated to transform an EV from a passive load into an active asset within a Building Energy Management System (BEMS). Its primary contribution is a hierarchical, price-aware control architecture that manages energy flows based on real-time system states (Surplus, Deficit, Idle), incorporating advanced mechanisms for resilience such as state-transition debouncing and exponential backoff for communication reliability. While presented as a design framework, the algorithmic logic is structured to theoretically achieve peak demand reduction and lower daily energy costs by prioritizing local asset discharge during high-price intervals. This paper establishes the RSDA as a technically robust pathway for leveraging Vehicle-to-Building (V2B) technology, offering a blueprint for enhancing building energy resilience and unlocking new economic value from EV assets.

11 June 2026 in EPJ Web of Conferences
Verified
Journal Article
Open access
Vladimír SzomosiVladimír Szomosi
Vladimír Szomosi
JŠJúlius Šimčák
Július Šimčák
MVMatej Vaľko
Matej Vaľko
ZČZsolt Čonka
Zsolt Čonka
This comprehensive review explores V2G, where electric vehicles act as mobile energy storage assets for the grid. We systematically analyze the core components of the V2G ecosystem, including bidirectional power electronics, advanced communication protocols such as ISO 15118, and emerging control architectures. The paper evaluates the portfolio of ancillary services that V2G can provide, such as frequency regulation, peak load shaving, and renewable energy firming, while also quantifying the potential adverse impacts on grid stability, including harmonic distortion and voltage fluctuations. Critical barriers to widespread adoption are examined in depth, with a particular focus on the techno-economic implications of battery degradation and the systemic vulnerabilities introduced by cybersecurity threats. Mitigation strategies, including degradation-aware charging algorithms and robust security frameworks leveraging Public Key Infrastructure (PKI) and Transport Layer Security (TLS), are discussed. A techno-economic analysis reveals that V2G profitability is highly contingent on regional electricity market structures and battery chemistry. Our Levelized Cost of Storage (LCOS) analysis indicates that Lithium Iron Phosphate (LFP) chemistry reduces costs by up to 76.3%. Synthesizing findings from international pilots, we highlight deployment status and lessons learned. V2G grid resilience requires overcoming technical, economic, and security challenges.

2 September 2026 in Solar
Verified
Journal Article
Open access
PDF file
MBMarek Bobcek
Marek Bobcek
JKJozef Király
Jozef Király
Vladimír SzomosiVladimír Szomosi
Vladimír Szomosi
ZČZsolt Čonka
Zsolt Čonka
ZVZoltan Varga
Zoltan Varga
VĐVeljko Đurković
Veljko Đurković
Battery energy storage systems (BESSs) are increasingly coupled with photovoltaic (PV) generation, yet their deployment is governed by economics rather than by technical feasibility. This review synthesises 122 indexed Q1/Q2 studies (2016–2026) on the financial payback and return on investment of PV-coupled storage, extending the analysis to vehicle-to-grid (V2G) integration. Records retrieved from Scopus, Web of Science, IEEE Xplore, and the MDPI portal were screened to peer-reviewed journals, assigned to ten thematic clusters, appraised against a ten-criterion reporting-transparency rubric, and combined by narrative synthesis. Reported payback periods range from a few years to beyond the asset’s service life, and the levelized cost of storage spans roughly 170–350 USD/MWh. In the reviewed corpus, the retail-to-export price spread, the stacking of self-consumption, arbitrage, grid-service revenues, and degradation-aware operation each move returns in a consistent direction, whereas which of them binds hardest is a property of the case rather than a ranking the evidence supports. V2G is almost always analysed in isolation from stationary storage; an illustrative harmonised comparison indicates that it substitutes for stationary capacity rather than adding to it. The review maps the combined PV+BESS+V2G revenue stack and identifies an integrated, degradation-corrected, policy-sensitive economic model as the principal research gap.

22 September 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RŠRóbert Štefko
Róbert Štefko
Vladimír SzomosiVladimír Szomosi
Vladimír Szomosi
MBMarek Bobcek
Marek Bobcek
JKJozef Király
Jozef Király
ZČZsolt Čonka
Zsolt Čonka
ECErik Chabreček
Erik Chabreček
Vehicle-to-grid (V2G) aggregators must commit energy and power that connected vehicles can actually deliver, yet they often observe only charger-side telemetry, and vehicle-reported state of charge (SOC) is optional or non-authoritative. This paper proposes an observability-aware framework for estimating tradeable V2G capacity: each session is classified by its measurement boundary, channels, sampling, latency, and setpoint control, then mapped to the battery through uncertain conversion paths. The estimator outputs conservative safe energy and safe power rather than absolute SOC, treats vehicle-reported values as noisy hints, and abstains when observability is insufficient. A reproducible synthetic study shows that regularization and a split-conformal margin bring the bound to the 95% target with a finite-sample guarantee under within-regime exchangeability, and that the required capacity haircut grows from about 2.6 through 4.3 to 6.5 SOC points as observability degrades. Coverage alone does not distinguish the method, since any conformalized predictor reaches the target; the observability-aware bound adds tradeable capacity at that coverage, and its advantage grows as telemetry degrades. End-to-end market deliverability is established only in synthesis: a laboratory proof of concept on one bidirectional charger with four production vehicles demonstrates AC-boundary telemetry ingestion and capability assignment, but measures realized throughput after the fact rather than a bound committed before dispatch.