FATMA ÇELİK

Dr. FATMA ÇELİK

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2026 in Obesity Surgery
Verified
Journal Article
Open access
PDF file
FÇFATMA ÇELİK
FATMA ÇELİK
RDRecai Dagli
Recai Dagli
AAAhmet Aksu
Ahmet Aksu
MHMurat Harman
Murat Harman
EBEsef Bolat
Esef Bolat
AAAysun Yıldız Altun
Aysun Yıldız Altun
Background: Pneumoperitoneum and the reverse Trendelenburg (RT) position during laparoscopic sleeve gastrectomy (LSG) can induce autonomic instability and increase the risk of arrhythmias by reducing venous return. This study aimed to evaluate the impact of surgical positioning during LSG on autonomic cardiac function, using hemodynamic parameters and the cardiac electrophysiological balance index (iCEB = QT/QRS) as a biomarker. Methods: This prospective observational study included 66 patients with severe obesity who underwent LSG. Measurements were recorded at five distinct time points, corresponding to specific patient positioning during the procedure: P-baseline (before induction, supine), P1 (after induction, supine), P2 (after pneumoperitoneum, supine), P3 (during pneumoperitoneum, RT), and P4 (after desufflation, RT). Results: Systolic, diastolic, and mean arterial pressures (SAP, DAP, and MAP) significantly decreased at all positions compared to baseline ( p < 0.001 for each). Compared to post-induction (P1), SAP values were substantially higher in the P2 and P4 positions ( p < 0.05, p < 0.001, respectively). Heart rate significantly decreased at P1 compared to baseline ( p < 0.004) and subsequently increased at P2 and P3 relative to P1 ( p < 0.001 and p < 0.009, respectively). A notable increase in iCEB was observed at P4 when compared to P1, P2, and P3 ( p < 0.003, p < 0.001, and p < 0.021, respectively). Despite these changes, iCEB values remained within the reference range across all measured positions. Conclusion: Despite the observed effects of positional changes and pneumoperitoneum on hemodynamic and cardiac electrical parameters during LSG, most patients tolerated these changes well. Crucially, iCEB values remained within the normal reference range throughout the procedure, indicating preserved cardiac autonomic regulation.

22 May 2026 in Obesity Surgery
Verified
Journal Article
Open access
PDF file
FDFurkan Doğan
Furkan Doğan
FÇFATMA ÇELİK
FATMA ÇELİK
Background: High intra-abdominal pressure (IAP) during bariatric surgery may compromise cerebral perfusion. This study evaluates the impact of 12 vs. 16 mmHg pneumoperitoneum on internal carotid artery (ICA) hemodynamics and cerebral oxygenation (rSO 2 ) in patients with severe obesity undergoing laparoscopic sleeve gastrectomy (LSG). Methods: In this prospective, randomized, double-blind study, 67 patients undergoing LSG were allocated into two groups: Group 12 (12 mmHg, n = 34) and Group 16 (16 mmHg, n = 33). Internal carotid artery velocity-time integral (VTI), internal carotid artery blood flow (ICABF), and rSO 2 were recorded at seven time points (T 0 to T 6 ). Acute positional and cumulative pressure effects were analyzed using delta (Δ) change values. Results: Systemic hemodynamics remained stable across groups ( P > 0.05). However, Group 16 showed significantly greater cumulative reductions in both ICA-VTI and ICABF compared to Group 12, particularly during the T 0 –T 6 period ( P < 0.001). Specifically, the decline in ICABF for Group 16 was significantly more pronounced at T 0 –T 6 (-161.89 vs. -107.41; P = 0.004) and T 2 –T 4 (-87.95 vs. -72.06; P = 0.036). The combined effect of pneumoperitoneum and reverse Trendelenburg position (T 2 –T 3 ) induced a significantly greater acute reduction in rSO 2 in Group 16 (Δ: -1.82) than in Group 12 (Δ: -0.24; P = 0.029). Conclusion: Elevated 16 mmHg IAP exerts a subclinical hemodynamic burden by straining cerebral reserves through cumulative ICABF reduction and acute rSO 2 declines. An initial pressure of 12 mmHg may be recommended to optimize neuro-hemodynamic stability, with subsequent adjustments tailored to surgical requirements and patient needs.