Massimo De Vittorio

Dr. Massimo De Vittorio

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2006 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
PPP. P. Pompa
P. P. Pompa
LML. Martiradonna
L. Martiradonna
ATAntonio Della Torre
Antonio Della Torre
Fabio Della SalaFabio Della Sala
Fabio Della Sala
LML. Manna
L. Manna
Rosaria RinaldiRosaria Rinaldi
Rosaria Rinaldi

7 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Roberto de FazioRoberto de Fazio
Roberto de Fazio
VMVincenzo Mariano Mastronardi
Vincenzo Mariano Mastronardi
MVMassimo De Vittorio
Massimo De Vittorio
Paolo ViscontiPaolo Visconti
Paolo Visconti
A quantitative evaluation of kinetic parameters, the joint’s range of motion, heart rate, and breathing rate, can be employed in sports performance tracking and rehabilitation monitoring following injuries or surgical operations. However, many of the current detection systems are expensive and designed for clinical use, requiring the presence of a physician and medical staff to assist users in the device’s positioning and measurements. The goal of wearable sensors is to overcome the limitations of current devices, enabling the acquisition of a user’s vital signs directly from the body in an accurate and non–invasive way. In sports activities, wearable sensors allow athletes to monitor performance and body movements objectively, going beyond the coach’s subjective evaluation limits. The main goal of this review paper is to provide a comprehensive overview of wearable technologies and sensing systems to detect and monitor the physiological parameters of patients during post–operative rehabilitation and athletes’ training, and to present evidence that supports the efficacy of this technology for healthcare applications. First, a classification of the human physiological parameters acquired from the human body by sensors attached to sensitive skin locations or worn as a part of garments is introduced, carrying important feedback on the user’s health status. Then, a detailed description of the electromechanical transduction mechanisms allows a comparison of the technologies used in wearable applications to monitor sports and rehabilitation activities. This paves the way for an analysis of wearable technologies, providing a comprehensive comparison of the current state of the art of available sensors and systems. Comparative and statistical analyses are provided to point out useful insights for defining the best technologies and solutions for monitoring body movements. Lastly, the presented review is compared with similar ones reported in the literature to highlight its strengths and novelties.

1 June 2014 in Neuron
Verified
Journal Article
Closed access
FPFerruccio Pisanello
Ferruccio Pisanello
LSLeonardo Sileo
Leonardo Sileo
IOIan A. Oldenburg
Ian A. Oldenburg
MPMarco Pisanello
Marco Pisanello
LMLuigi Martiradonna
Luigi Martiradonna
MVMassimo De Vittorio
Massimo De Vittorio

7 October 2019 in Nature Methods
Verified
Journal Article
Closed access
PDF file
FPFilippo Pisano
Filippo Pisano
MPMarco Pisanello
Marco Pisanello
SLSuk Joon Lee
Suk Joon Lee
JLJaeeon Lee
Jaeeon Lee
EMEmanuela Maglie
Emanuela Maglie
FPFerruccio Pisanello
Ferruccio Pisanello

22 February 2023 in Advanced Functional Materials
Verified
Journal Article
Open access
ABAntonio Balena
Antonio Balena
MBMarco Bianco
Marco Bianco
FPFerruccio Pisanello
Ferruccio Pisanello
MVMassimo De Vittorio
Massimo De Vittorio
Two‐Photon Lithography, thanks to its very high sub‐diffraction resolution, has become the lithographic technique par excellence in applications requiring small feature sizes and complex 3D pattering. Despite this, the fabrication times required for extended structures remain much longer than those of other competing techniques (UV mask lithography, nanoimprinting, etc.). Its low throughput prevents its wide adoption in industrial applications. To increase it, over the years different solutions have been proposed, although their usage is difficult to generalize and may be limited depending on the specific application. A promising strategy to further increase the throughput of Two‐Photon Lithography, opening a concrete window for its adoption in industry, lies in its combination with holography approaches: in this way it is possible to generate dozens of foci from a single laser beam, thus parallelizing the fabrication of periodic structures, or to engineer the intensity distribution on the writing plane in a complex way, obtaining 3D microstructures with a single exposure. Here, the fundamental concepts behind high‐speed Two‐Photon Lithography and its combination with holography are discussed, and the literary production of recent years that exploits such techniques is reviewed, and contextualized according to the topic covered.

12 December 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
Marco GrandeMarco Grande
Marco Grande
Maria Antonietta VincentiMaria Antonietta Vincenti
Maria Antonietta Vincenti
TST. Stomeo
T. Stomeo
GBGiuseppe Valerio Bianco
Giuseppe Valerio Bianco
Domenico de CegliaDomenico de Ceglia
Domenico de Ceglia
ADA. D’oRazio
A. D’oRazio
A one-dimensional dielectric grating, based on a simple geometry, is proposed and investigated to enhance light absorption in a monolayer graphene exploiting guided mode resonances. Numerical findings reveal that the optimized configuration is able to absorb up to 60% of the impinging light at normal incidence for both TE and TM polarizations resulting in a theoretical enhancement factor of about 26 with respect to the monolayer graphene absorption (≈2.3%). Experimental results confirm this behavior showing CVD graphene absorbance peaks up to about 40% over narrow bands of a few nanometers. The simple and flexible design points to a way to realize innovative, scalable and easy-to-fabricate graphene-based optical absorbers.