Peter Gehlbach

Peter Gehlbach


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BGBerk Gonenc
Berk Gonenc
ACAlireza Chamani
Alireza Chamani
JHJames T Handa
James T Handa
PGPeter Gehlbach
Peter Gehlbach
RTRussell H. Taylor
Russell H. Taylor
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
In vitreoretinal surgery, membrane peeling is a prototypical task where a layer of fibrous tissue is delaminated off the retina with a micro-forceps by applying very fine forces that are mostly imperceptible to the surgeon. Previously, we developed sensitized ophthalmic surgery tools based on fiber Bragg grating strain sensors, which were shown to precisely detect forces at the instrument's tip in two degrees of freedom perpendicular to the tool axis. This paper presents a new design that employs an additional sensor to capture also the tensile force along the tool axis. The grasping functionality is provided via a compact motorized unit. To compute forces, we investigate two distinct fitting methods: a linear regression and a nonlinear fitting based on second-order Bernstein polynomials. We carry out experiments to test the repeatability of sensor outputs, calibrate the sensor, and validate its performance. Results demonstrate sensor wavelength repeatability within 2 pm. Although the linear method provides sufficient accuracy in measuring transverse forces, in the axial direction, it produces a root mean square (rms) error over 3 mN even for a confined magnitude and direction of forces. On the other hand, the nonlinear method provides a more consistent and accurate measurement of both the transverse and axial forces for the entire force range (0-25 mN). Validation, including random samples, shows that our tool with the nonlinear force computation method can predict 3-D forces with an rms error under 0.15 mN in the transverse plane and within 2 mN accuracy in the axial direction.

1 August 2012
Verified
Conference Paper
Closed access
IKIsmail Kuru
Ismail Kuru
BGBerk Gonenc
Berk Gonenc
MBMarcin Balicki
Marcin Balicki
JHJames T Handa
James T Handa
PGPeter Gehlbach
Peter Gehlbach
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
Membrane peeling is a standard vitreoretinal procedure, where the surgeon delaminates a very thin membrane from retina surface using surgical picks and forceps. This requires extremely delicate manipulation of the retinal tissue. Applying excessive forces during the surgery can cause serious complications leading to vision loss. For successful membrane peeling, most of the applied forces need to be very small, well below the human tactile sensation threshold. In this paper, we present a robotic system that combines a force sensing forceps tool and a cooperatively-controlled surgical robot. This combination allows us to measure the forces directly at the tool tip and use this information for limiting the applied forces on the retina. This may prevent many iatrogenic injuries and allow safer maneuvers during vitreoretinal procedures. We show that our system can successfully eliminate hand-tremor and excessive forces in membrane peeling experiments on the inner shell membrane of a chicken embryo.

6 April 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AEAli Ebrahimi
Ali Ebrahimi
MUMuller G. Urias
Muller G. Urias
NPNiravkumar Patel
Niravkumar Patel
RTRussell H. Taylor
Russell H. Taylor
PGPeter Gehlbach
Peter Gehlbach
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
The integration of robotics into retinal microsurgery leads to a reduction in surgeon perception of tool-to-tissue interaction forces. This blunting of human tactile sensory input, which is due to the inflexible mass and large inertia of the robotic arm as compared to the milli-Newton scale of the interaction forces and fragile tissues during ophthalmic surgery, identifies a potential iatrogenic risk during robotic eye surgery. In this paper, we aim to evaluate two variants of an adaptive force control scheme implemented on the Steady-Hand Eye Robot (SHER) that are intended to mitigate the risk of unsafe scleral forces. The present study enrolled ten retina fellows and ophthalmology residents into a simulated procedure, which simply asked the trainees to follow retinal vessels in a model retina surgery environment. For this purpose, we have developed a force-sensing (equipped with Fiber Bragg Grating (FBG)) instrument to attach to the robot. A piezo-actuated linear stage for creating random lateral motions to the eyeball phantom has been provided to simulate disturbances during surgery. The SHER and all of its dependencies were set up in an operating room in the Wilmer Eye Institute at the Johns Hopkins Hospital. The clinicians conducted robot-assisted experiments with the adaptive controls incorporated as well as freehand manipulations. The results indicate that the Adaptive Norm Control (ANC) method, is able to maintain scleral forces at predetermined safe levels better than even freehand manipulations. Novice clinicians in robot training however, subjectively preferred freehand maneuvers over robotic manipulations. Clinician preferences once highly skilled with the robot is not assessed in this study.

1 October 2012
Verified
Conference Paper
Closed access
BGBerk Gonenc
Berk Gonenc
MBMarcin A. Balicki
Marcin A. Balicki
JHJames T Handa
James T Handa
PGPeter Gehlbach
Peter Gehlbach
CRCameron N. Riviere
Cameron N. Riviere
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
Highly accurate positioning is fundamental to the performance of vitreoretinal microsurgery. Of vitreoretinal procedures, membrane peeling is among the most prone to complications since extremely delicate manipulation of retinal tissue is required. Associated tool-to-tissue interaction forces are usually below the threshold of human perception, and the surgical tools are moved very slowly, within the 0.1-0.5 mm/s range. During the procedure, unintentional tool motion and excessive forces can easily give rise to vision loss or irreversible damage to the retina. A successful surgery includes two key features: controlled tremor-free tool motion and control of applied force. In this study, we present the potential benefits of a micro-force sensing robot in vitreoretinal surgery. Our main contribution is implementing fiber Bragg grating based force sensing in an active tremor canceling handheld micromanipulator, known as Micron, to measure tool-to-tissue interaction forces in real time. Implemented auditory sensory substitution assists in reducing and limiting forces. In order to test the functionality and performance, the force sensing Micron was evaluated in peeling experiments with adhesive bandages and with the inner shell membrane from chicken eggs. Our findings show that the combination of active tremor canceling together with auditory sensory substitution is the most promising aid that keeps peeling forces below 7 mN with a significant reduction in 2-20 Hz oscillations.

4 August 2016 in Cochrane Database of Systematic Reviews
Verified
Journal Article
Closed access
PDF file
PGPeter Gehlbach
Peter Gehlbach
TLTianjing Li
Tianjing Li
EHElham Hatef
Elham Hatef

23 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
BGBerk Gonenc
Berk Gonenc
JCJeremy Chae
Jeremy Chae
PGPeter Gehlbach
Peter Gehlbach
RTRussell H. Taylor
Russell H. Taylor
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
Retinal vein cannulation is a technically demanding surgical procedure where therapeutic agents are injected into the retinal veins to treat occlusions. The clinical feasibility of this approach has been largely limited by the technical challenges associated with performing the procedure. Among the challenges to successful vein cannulation are identifying the moment of venous puncture, achieving cannulation of the micro-vessel, and maintaining cannulation throughout drug delivery. Recent advances in medical robotics and sensing of tool-tissue interaction forces have the potential to address each of these challenges as well as to prevent tissue trauma, minimize complications, diminish surgeon effort, and ultimately promote successful retinal vein cannulation. In this paper, we develop an assistive system combining a handheld micromanipulator, called “Micron”, with a force-sensing microneedle. Using this system, we examine two distinct methods of precisely detecting the instant of venous puncture. This is based on measured tool-tissue interaction forces and also the tracked position of the needle tip. In addition to the existing tremor canceling function of Micron, a new control method is implemented to actively compensate unintended movements of the operator, and to keep the cannulation device securely inside the vein following cannulation. To demonstrate the capabilities and performance of our uniquely upgraded system, we present a multi-user artificial phantom study with subjects from three different surgical skill levels. Results show that our puncture detection algorithm, when combined with the active positive holding feature enables sustained cannulation which is most evident in smaller veins. Notable is that the active holding function significantly attenuates tool motion in the vein, thereby reduces the trauma during cannulation.