Wojciech Swieszkowski

Prof. Dr. Wojciech Swieszkowski

Faculty of Materials Science and Engineering, Warsaw University of Technology, Warsaw, Poland

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Advanced Drug Delivery Reviews
Verified
Journal Article
Open access
SSSaghi Saghazadeh
Saghi Saghazadeh
CRChiara Rinoldi
Chiara Rinoldi
MSMaik Schot
Maik Schot
SKSara Saheb Kashaf
Sara Saheb Kashaf
FSFatemeh Sharifi
Fatemeh Sharifi
Ali  KhademhosseiniAli Khademhosseini
Ali Khademhosseini
Chronic, non-healing wounds place a significant burden on patients and healthcare systems, resulting in impaired mobility, limb amputation, or even death. Chronic wounds result from a disruption in the highly orchestrated cascade of events involved in wound closure. Significant advances in our understanding of the pathophysiology of chronic wounds have resulted in the development of drugs designed to target different aspects of the impaired processes. However, the hostility of the wound environment rich in degradative enzymes and its elevated pH, combined with differences in the time scales of different physiological processes involved in tissue regeneration require the use of effective drug delivery systems. In this review, we will first discuss the pathophysiology of chronic wounds and then the materials used for engineering drug delivery systems. Different passive and active drug delivery systems used in wound care will be reviewed. In addition, the architecture of the delivery platform and its ability to modulate drug delivery are discussed. Emerging technologies and the opportunities for engineering more effective wound care devices are also highlighted.

1 July 2017 in Biomaterials
Verified
Journal Article
Open access
Marco CostantiniMarco Costantini
Marco Costantini
STStefano Testa
Stefano Testa
PMPamela Mozetic
Pamela Mozetic
ABAndrea Barbetta
Andrea Barbetta
CFClaudia Fuoco
Claudia Fuoco
CGCesare Gargioli
Cesare Gargioli
We present a new strategy for the fabrication of artificial skeletal muscle tissue with functional morphologies based on an innovative 3D bioprinting approach. The methodology is based on a microfluidic printing head coupled to a co-axial needle extruder for high-resolution 3D bioprinting of hydrogel fibers laden with muscle precursor cells (C2C12). To promote myogenic differentiation, we formulated a tailored bioink with a photocurable semi-synthetic biopolymer (PEG-Fibrinogen) encapsulating cells into 3D constructs composed of aligned hydrogel fibers. After 3-5 days of culture, the encapsulated myoblasts started migrating and fusing, forming multinucleated myotubes within the 3D bioprinted fibers. The obtained myotubes showed high degree of alignment along the direction of hydrogel fiber deposition, further revealing maturation, sarcomerogenesis, and functionality. Following subcutaneous implantation in the back of immunocompromised mice, bioprinted constructs generated organized artificial muscle tissue in vivo. Finally, we demonstrate that our microfluidic printing head allows to design three dimensional multi-cellular assemblies with an exquisite compartmentalization of the encapsulated cells. Our results demonstrate an enhanced myogenic differentiation with the formation of parallel aligned long-range myotubes. The approach that we report here represents a robust and valid candidate for the fabrication of macroscopic artificial muscle to scale up skeletal muscle tissue engineering for human clinical application.

26 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BWBartlomiej Wysocki
Bartlomiej Wysocki
PMPiotr Maj
Piotr Maj
RSRyszard Sitek
Ryszard Sitek
Joseph BuhagiarJoseph Buhagiar
Joseph Buhagiar
KKKrzysztof Kurzydlowski
Krzysztof Kurzydlowski
WŚWojciech Święszkowski
Wojciech Święszkowski
Additive Manufacturing (AM) methods are generally used to produce an early sample or near net-shape elements based on three-dimensional geometrical modules. To date, publications on AM of metal implants have mainly focused on knee and hip replacements or bone scaffolds for tissue engineering. The direct fabrication of metallic implants can be achieved by methods, such as Selective Laser Melting (SLM) or Electron Beam Melting (EBM). This work compares the SLM and EBM methods used in the fabrication of titanium bone implants by analyzing the microstructure, mechanical properties and cytotoxicity. The SLM process was conducted in an environmental chamber using 0.4–0.6 vol % of oxygen to enhance the mechanical properties of a Ti-6Al-4V alloy. SLM processed material had high anisotropy of mechanical properties and superior UTS (1246–1421 MPa) when compared to the EBM (972–976 MPa) and the wrought material (933–942 MPa). The microstructure and phase composition depended on the used fabrication method. The AM methods caused the formation of long epitaxial grains of the prior β phase. The equilibrium phases (α + β) and non-equilibrium α’ martensite was obtained after EBM and SLM, respectively. Although it was found that the heat transfer that occurs during the layer by layer generation of the component caused aluminum content deviations, neither methods generated any cytotoxic effects. Furthermore, in contrast to SLM, the EBM fabricated material met the ASTMF136 standard for surgical implant applications.

5 August 2010 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
BDBogdan Dabrowski
Bogdan Dabrowski
WŚWojciech Święszkowski
Wojciech Święszkowski
DGDirk Godlinski
Dirk Godlinski
KKKrzysztof J. Kurzydlowski
Krzysztof J. Kurzydlowski

19 July 2016 in Biofabrication
Verified
Journal Article
Closed access
PDF file
Marco CostantiniMarco Costantini
Marco Costantini
JIJoanna Idaszek
Joanna Idaszek
KSKrisztina Szöke
Krisztina Szöke
JJJakub Jaroszewicz
Jakub Jaroszewicz
MDMariella Dentini
Mariella Dentini
WŚWojciech Święszkowski
Wojciech Święszkowski
In this work we demonstrate how to print 3D biomimetic hydrogel scaffolds for cartilage tissue engineering with high cell density (>10 7 cells ml −1 ), high cell viability (85 ÷ 90%) and high printing resolution (≈100 μ m) through a two coaxial-needles system. The scaffolds were composed of modified biopolymers present in the extracellular matrix (ECM) of cartilage, namely gelatin methacrylamide (GelMA), chondroitin sulfate amino ethyl methacrylate (CS-AEMA) and hyaluronic acid methacrylate (HAMA). The polymers were used to prepare three photocurable bioinks with increasing degree of biomimicry: (i) GelMA, (ii) GelMA + CS-AEMA and (iii) GelMA + CS-AEMA + HAMA. Alginate was added to the bioinks as templating agent to form stable fibers during 3D printing. In all cases, bioink solutions were loaded with bone marrow-derived human mesenchymal stem cells (BM-MSCs). After printing, the samples were cultured in expansion (negative control) and chondrogenic media to evaluate the possible differentiating effect exerted by the biomimetic matrix or the synergistic effect of the matrix and chondrogenic supplements. After 7, 14, and 21 days, gene expression of the chondrogenic markers (COL2A1 and aggrecan), marker of osteogenesis (COL1A1) and marker of hypertrophy (COL10A1) were evaluated qualitatively by means of fluorescence immunocytochemistry and quantitatively by means of RT-qPCR. The observed enhanced viability and chondrogenic differentiation of BM-MSCs, as well as high robustness and accuracy of the employed deposition method, make the presented approach a valid candidate for advanced engineering of cartilage tissue.

10 March 2016 in Scientific Reports
Verified
Journal Article
Open access
ALAndrea Di Luca
Andrea Di Luca
BOBarbara Ostrowska
Barbara Ostrowska
ILIvan Lorenzo-Moldero
Ivan Lorenzo-Moldero
Antonio Junior LepeddaAntonio Junior Lepedda
Antonio Junior Lepedda
WŚWojciech Święszkowski
Wojciech Święszkowski
Lorenzo MoroniLorenzo Moroni
Lorenzo Moroni
Small fractures in bone tissue can heal by themselves, but in case of larger defects current therapies are not completely successful due to several drawbacks. A possible strategy relies on the combination of additive manufactured polymeric scaffolds and human mesenchymal stromal cells (hMSCs). The architecture of bone tissue is characterized by a structural gradient. Long bones display a structural gradient in the radial direction, while flat bones in the axial direction. Such gradient presents a variation in bone density from the cancellous bone to the cortical bone. Therefore, scaffolds presenting a gradient in porosity could be ideal candidates to improve bone tissue regeneration. In this study, we present a construct with a discrete gradient in pore size and characterize its ability to further support the osteogenic differentiation of hMSCs. Furthermore, we studied the behaviour of hMSCs within the different compartments of the gradient scaffolds, showing a correlation between osteogenic differentiation and ECM mineralization, and pore dimensions. Alkaline phosphatase activity and calcium content increased with increasing pore dimensions. Our results indicate that designing structural porosity gradients may be an appealing strategy to support gradual osteogenic differentiation of adult stem cells.