Joseph Buhagiar

Prof. Joseph Buhagiar

University of Malta
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BWBartlomiej Wysocki
Bartlomiej Wysocki
PMPiotr Maj
Piotr Maj
RSRyszard Sitek
Ryszard Sitek
Joseph BuhagiarJoseph Buhagiar
Joseph Buhagiar
KKKrzysztof Kurzydlowski
Krzysztof Kurzydlowski
WŚWojciech Święszkowski
Wojciech Święszkowski
Additive Manufacturing (AM) methods are generally used to produce an early sample or near net-shape elements based on three-dimensional geometrical modules. To date, publications on AM of metal implants have mainly focused on knee and hip replacements or bone scaffolds for tissue engineering. The direct fabrication of metallic implants can be achieved by methods, such as Selective Laser Melting (SLM) or Electron Beam Melting (EBM). This work compares the SLM and EBM methods used in the fabrication of titanium bone implants by analyzing the microstructure, mechanical properties and cytotoxicity. The SLM process was conducted in an environmental chamber using 0.4–0.6 vol % of oxygen to enhance the mechanical properties of a Ti-6Al-4V alloy. SLM processed material had high anisotropy of mechanical properties and superior UTS (1246–1421 MPa) when compared to the EBM (972–976 MPa) and the wrought material (933–942 MPa). The microstructure and phase composition depended on the used fabrication method. The AM methods caused the formation of long epitaxial grains of the prior β phase. The equilibrium phases (α + β) and non-equilibrium α’ martensite was obtained after EBM and SLM, respectively. Although it was found that the heat transfer that occurs during the layer by layer generation of the component caused aluminum content deviations, neither methods generated any cytotoxic effects. Furthermore, in contrast to SLM, the EBM fabricated material met the ASTMF136 standard for surgical implant applications.

1 February 2019 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
BWBartlomiej Wysocki
Bartlomiej Wysocki
JIJoanna Idaszek
Joanna Idaszek
Joseph BuhagiarJoseph Buhagiar
Joseph Buhagiar
KSKarol Szlazak
Karol Szlazak
TBTomasz Brynk
Tomasz Brynk
WŚWojciech Święszkowski
Wojciech Święszkowski

1 April 2015 in Acta Biomaterialia
Verified
Journal Article
Closed access
COCamillus Sunday Obayi
Camillus Sunday Obayi
RTRanna Tolouei
Ranna Tolouei
DMDiego Mantovani
Diego Mantovani
STStephane Turgeon
Stephane Turgeon
BOBoniface Adeleh Okorie
Boniface Adeleh Okorie
DMDiego Mantovani
Diego Mantovani

1 October 2009 in Surface and Coatings Technology
Verified
Journal Article
Closed access
Joseph BuhagiarJoseph Buhagiar
Joseph Buhagiar
XLXiaoying Li
Xiaoying Li
HDHanshan Dong
Hanshan Dong

17 November 2020 in Metals
Verified
Journal Article
Open access
PDF file
BHBranislav Hadzima
Branislav Hadzima
DKDaniel Kajánek
Daniel Kajánek
MJMichal Jambor
Michal Jambor
JDJuliána Drábiková
Juliána Drábiková
MBMatěj Březina
Matěj Březina
MJMartina Jacková
Martina Jacková
In this work, the quality of coatings prepared by plasma electrolytic oxidation (PEO) on an AZ31 magnesium alloy were evaluated. This was done by studying the effects of the chemical composition of phosphate-based process electrolytes in combination with different applied current densities on coating thickness, porosity, micro-cracking and corrosion resistance in 0.1 M NaCl. Both processing parameters were studied in four different levels. Mid-term corrosion resistance in 0.1 M NaCl was examined by electrochemical impedance spectroscopy and based on this, corrosion mechanisms were hypothesized. Results of performed experiments showed that the chosen processing parameters and electrolyte composition significantly influenced the morphology and corrosion performance of the prepared PEO coatings. The PEO coating prepared in an electrolyte with 12 g/L Na3PO4·12H2O and using an applied current density 0.05 A/cm2 reached the highest value of polarization resistance. This was more than 11 times higher when compared to the uncoated counterpart.

5 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
ACAgnieszka Chmielewska
Agnieszka Chmielewska
BWBartlomiej Wysocki
Bartlomiej Wysocki
PKPiotr Kwaśniak
Piotr Kwaśniak
Mirosław Jakub KruszewskiMirosław Jakub Kruszewski
Mirosław Jakub Kruszewski
BMBartosz Michalski
Bartosz Michalski
WŚWojciech Święszkowski
Wojciech Święszkowski
The use of elemental metallic powders and in situ alloying in additive manufacturing (AM) is of industrial relevance as it offers the required flexibility to tailor the batch powder composition. This solution has been applied to the AM manufacturing of nickel-titanium (NiTi) shape memory alloy components. In this work, we show that laser powder bed fusion (LPBF) can be used to create a Ni55.7Ti44.3 alloyed component, but that the chemical composition of the build has a large heterogeneity. To solve this problem three different annealing heat treatments were designed, and the resulting porosity, microstructural homogeneity, and phase formation was investigated. The heat treatments were found to improve the alloy’s chemical and phase homogeneity, but the brittle NiTi2 phase was found to be stabilized by the 0.54 wt.% of oxygen present in all fabricated samples. As a consequence, a Ni2Ti4O phase was formed and was confirmed by transmission electron microscopy (TEM) observation. This study showed that pore formation in in situ alloyed NiTi can be controlled via heat treatment. Moreover, we have shown that the two-step heat treatment is a promising method to homogenise the chemical and phase composition of in situ alloyed NiTi powder fabricated by LPBF.