Emin Yeşil

Dr. Emin Yeşil

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2023 in Journal of Polytechnic
Verified
Journal Article
Open access
PDF file
Muharrem Hilmi AKSOYMuharrem Hilmi AKSOY
Muharrem Hilmi AKSOY
MIMurat İspi̇r
Murat İspi̇r
EYEmin Yeşil
Emin Yeşil
The optimum tilt angle for a photovoltaic (PV) system depends on the row spacing because it affects the amount of shading on the panels. This study modeled PV systems for four different panel row spacings of 2 m, 2.5 m, 3 m, and 4 m in a fixed 3000 m² area in Konya province, Turkey. For different panel row spacings, the system performances were compared using a constant tilt angle of 35°, expressed as a proper angle for PV installations at the considered location. In addition, the optimum tilt angle is found for four different cases in terms of electricity generation. In systems with 35° tilt angles at electricity were produced annually as 622.77 MWh, 566.49 MWh, 495.36 MWh, and 385.72 MWh, respectively, for panel row spacings of 2 m, 2.5 m, 3 m, and 4 m. In addition, these electricity productions are 6.19%, 4.41%, 2.56%, and 0.92% higher with optimum tilt angles as 1°, 15°, 21° and 27°. Similarly, the Performance Ratio (PR) values obtained with the optimum angles are 20.61%, 8.39%, 4.12%, and 1.44%, higher than the fixed tilt angle cases. According to the economic analysis, systems with a fixed tilt angle for these panel row spacings pay back themselves in 5.13, 4.67, 4.44, and 4.28 years, respectively, while systems at optimum angles pay back themselves in a shorter time by 5.83%, 4.26%, 2.49%, and 0.91%. Furthermore, the highest NPV/INV, IRR, and ROI values were obtained from the system with 3 m panel row spacing with the optimum tilt angle of 21° as 0.915, 20.42%, and 91.57%, respectively, which is techno economically found to be the most feasible case.

22 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
OUOğuzhan Uymaz
Oğuzhan Uymaz
EKErsin KAYA
Ersin KAYA
Sait Ali UymazSait Ali Uymaz
Sait Ali Uymaz
EYEmin Yeşil
Emin Yeşil
In industrial production processes, accurate and fast detection of band sawtooth deformations is of critical importance. Traditional detection approaches are not sustainable at industrial scale due to their high human attention requirements and low efficiency. In this study, we present RTC-DETR234, a task-specific configuration of the RT-DETR architecture designed for detecting small and low-contrast band sawtooth fractures. The proposed model uses the P2–P4 scales to provide higher-resolution feature extraction instead of the P3–P5 scaling structure of the baseline RT-DETR model. Furthermore, CBAM modules are integrated into the HGBlock-based backbone to refine channel- and spatial-level feature responses associated with small and low-contrast fracture regions. The proposed model, the baseline YOLO models, and the baseline RT-DETR model are trained and compared on a dataset consisting of band sawtooth defects. The proposed model achieved an average mAP of 0.9938 for tooth detection and 0.9178 for fracture detection across multiple independent runs.