Ahmad Bittar

Dr. Ahmad Bittar

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2024 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Open access
ABAhmad Bittar
Ahmad Bittar
TÇTuba Çetin
Tuba Çetin
GBGizem Meva Başyiğit
Gizem Meva Başyiğit
BGBurcu Gözetici-Çil
Burcu Gözetici-Çil
Objectives: The objective of this study was to evaluate the efficacy of a quantitative light-induced fluorescence (QLF) device (QrayCam Pro, AIOBIO, Seoul, Republic of Korea) in detecting and differentiating the severity of posterior proximal and occlusal primary caries. Materials and methods: The study included a total of 120 teeth in 60 patients (of both genders, aged between 21 and 38 years) between January and March 2024, one carious tooth and one sound tooth were selected at random in each patient. All occlusal surfaces were evaluated in accordance with the International Caries Detection and Assessment System (ICDAS) Nyvad Criteria, using the visual tactile method. The ICDAS employs a scoring system ranging from 0 to 6, while the Nyvad Criteria employs a similar scoring system. Addionally, the depth of the proximal lesions was scored (0-6) using bite-wing radiography. The quantitative values representing the maximum loss of fluorescence (Delta Fmax) and the maximum change in the ratio of red and green fluorescence (Delta Rmax) were obtained using the Q-ray Clinical software v 1.45. To assess the validity, the sensitivity, specificity, and area under the receiver operating characteristics curve (AUROC) were calculated. Spearman correlation coefficient was used to investigate the correlation between the findings of the traditional and QLF examination methods. Results: The AUROC values for both Delta Fmax and Delta Rmax were found to be excellent. The sensitivity of QrayCam Pro was found to be 84-88.6%, while the specificity was 100%. The correlation analysis demonstrated a strong correlation between scores obtained from the traditional examination and the QLF values. Conclusions: Based on the findings of this study, QrayCam Pro exhibits potential as a valuable additional tool for not only detecting caries but also for assessing their severity and activity. Clinical relevance: This study revealed that QrayCam Pro might be suggested as a precise tool for enhancing caries detection and assessment compared to traditional methods. By providing quantitative data on caries severity and activity, it enables more informed treatment decisions, potentially optimizing outcomes for patients.

21 May 2026 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ABAhmad Bittar
Ahmad Bittar
EAElif Alkan
Elif Alkan
ÖKÖzlem Kanar
Özlem Kanar
BKBora Korkut
Bora Korkut
DTDilek Tağtekin
Dilek Tağtekin
Proximal caries detection remains challenging because early lesions are often inaccessible to visual inspection and bitewing radiography exposes patients t


1 July 2026 in Cumhuriyet Dental Journal
Verified
Journal Article
Closed access
ABAhmad Bittar
Ahmad Bittar
EAElif Alkan
Elif Alkan
DTDilek Tagtekin
Dilek Tagtekin
Objectives: To compare the diagnostic performance of quadrant-focused (half-jaw) versus full-arch QLF imaging with QrayCam Pro for occlusal caries detection against a combined ICDAS+bitewing reference.Materials and Methods: Forty-five adults (mean age 25.1 years) each contributed one occlusal surface (sound or carious). Each surface was imaged under two protocols: quadrant-focused and full-arch. Q-ray Clinical software yielded ΔF_max (green fluorescence loss), ΔR_max (red fluorescence change), and QS scores. Diagnostic accuracy (sensitivity, specificity, area under the ROC curve [AUC]) was calculated versus the reference standard; protocol differences were assessed with MANOVA.Results: Both protocols showed high performance. For ΔR_max, both achieved AUC = 1.000 with 100% sensitivity and specificity. For ΔF_max, quadrant imaging achieved AUC = 1.000; full-arch had AUC = 0.993 (sensitivity 92.3%, specificity 94.7%). MANOVA found no significant overall difference between protocols (p = 0.790). Quadrant imaging tended to identify early enamel lesions more often.Conclusions: Quadrant-focused QLF imaging offers a small sensitivity advantage for incipient lesions while maintaining high specificity; full-arch imaging remains efficient for screening and documentation. Protocol choice can be tailored to early-lesion detection needs and AI-based analysis workflows.

17 July 2026 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
ABAhmad Bittar
Ahmad Bittar
EAElif Alkan
Elif Alkan
DTDilek Tağtekin
Dilek Tağtekin

20 July 2026 in Journal of Health Sciences and Medicine
Verified
Journal Article
Open access
ABAhmad Bittar
Ahmad Bittar
EAElif Alkan
Elif Alkan
BKBora Korkut
Bora Korkut
DTDilek Tagtekin
Dilek Tagtekin
Aims: To evaluate patient-reported comfort, gag reflex, and examination time across visual-tactile and adjunctive caries detection approaches, and to determine whether these outcomes differ according to interincisal distance.Methods: Adults aged 18-60 years attending routine visits between November 5, 2025 and February 5, 2026 underwent visual-tactile examination using the International Caries Detection and Assessment System II and 4 adjunctive methods: DIAGNOdent Pen (KaVo Dental GmbH, Biberach, Germany), QrayPen (AIOBIO, Seoul, Republic of Korea), QrayCam Pro (AIOBIO, Seoul, Republic of Korea), and iTero Element 5D (Align Technology, San Jose, CA, USA). Visual-tactile examination was performed first; adjunctive methods were applied in 2 counterbalanced randomized sequences. Maximum interincisal distance was categorized as ≤3,5 cm, 3,6-5,0 cm, or >5,0 cm. Comfort and gag reflex were rated on 3-point ordinal scales and quadrant examination time was categorized into 4 levels. Nonparametric tests were used.Results: Ninety-six participants were analyzed (mean age, 22,4 years). Outcomes did not differ by randomized sequence. Lower interincisal distance was associated with lower comfort and higher gag reflex for all adjunctive methods (all P ≤ ,01) and with longer time categories for QrayCam Pro, QrayPen, iTero Element 5D, and DIAGNOdent Pen (all P ≤ ,01). Across methods, comfort, gag reflex, and time differed (all P < ,001). QrayCam Pro was most frequently preferred (52/96; 54,2%), whereas iTero Element 5D was not selected.Conclusion: Interincisal distance is a practical indicator of patient tolerability and workflow impact when selecting adjunctive caries detection approaches.