Kyle S. Weber

Mr. Kyle S. Weber

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2023 in JMIR Formative Research
Verified
Journal Article
Open access
KWKyle S. Weber
Kyle S. Weber
FGF Elizabeth Godkin
F Elizabeth Godkin
BCBenjamin F Cornish
Benjamin F Cornish
WMWilliam McIlroy
William McIlroy
KOKaren Van Ooteghem
Karen Van Ooteghem
Background: Accurate measurement of daily physical activity (PA) is important as PA is linked to health outcomes in older adults and people living with complex health conditions. Wrist-worn accelerometers are widely used to estimate PA intensity, including walking, which composes much of daily PA. However, there is concern that wrist-derived PA data in these cohorts is unreliable due to slow gait speed, mobility aid use, disease-related symptoms that impact arm movement, and transient activities of daily living. Despite the potential for error in wrist-derived PA intensity estimates, their use has become ubiquitous in research and clinical application. Objective: The goals of this work were to (1) determine the accuracy of wrist-based estimates of PA intensity during known walking periods in older adults and people living with cerebrovascular disease (CVD) or neurodegenerative disease (NDD) and (2) explore factors that influence wrist-derived intensity estimates. Methods: A total of 35 older adults (n=23 with CVD or NDD) wore an accelerometer on the dominant wrist and ankle for 7 to 10 days of continuous monitoring. Stepping was detected using the ankle accelerometer. Analyses were restricted to gait bouts ≥60 seconds long with a cadence ≥80 steps per minute (LONG walks) to identify periods of purposeful, continuous walking likely to reflect moderate-intensity activity. Wrist accelerometer data were analyzed within LONG walks using 15-second epochs, and published intensity thresholds were applied to classify epochs as sedentary, light, or moderate-to-vigorous physical activity (MVPA). Participants were stratified into quartiles based on the percent of walking epochs classified as sedentary, and the data were examined for differences in behavioral or demographic traits between the top and bottom quartiles. A case series was performed to illustrate factors and behaviors that can affect wrist-derived intensity estimates during walking. Results: Participants averaged 107.7 (SD 55.8) LONG walks with a median cadence of 107.3 (SD 10.8) steps per minute. Across participants, wrist-derived intensity classification was 22.9% (SD 15.8) sedentary, 27.7% (SD 14.6) light, and 49.3% (SD 25.5) MVPA during LONG walks. All participants measured a statistically lower proportion of wrist-derived activity during LONG walks than expected (all P<.001), and 80% (n=28) of participants had at least 20 minutes of LONG walking time misclassified as sedentary based on wrist-derived intensity estimates. Participants in the highest quartile of wrist-derived sedentary classification during LONG walks were significantly older (t16=4.24, P<.001) and had more variable wrist movement (t16=2.13, P=.049) compared to those in the lowest quartile. Conclusions: The current best practice wrist accelerometer method is prone to misclassifying activity intensity during walking in older adults and people living with complex health conditions. A multidevice approach may be warranted to advance methods for accurately assessing PA in these groups.

24 October 2024 in Medical Engineering & Physics
Verified
Journal Article
Open access
BCBenjamin F Cornish
Benjamin F Cornish
KOKaren Van Ooteghem
Karen Van Ooteghem
MWMatthew Wong
Matthew Wong
KWKyle S. Weber
Kyle S. Weber
FPFrederico Pieruccini-Faria
Frederico Pieruccini-Faria
WMWilliam McIlroy
William McIlroy
Wearable sensors, including accelerometers, are a widely accepted tool to assess gait in clinical and free-living environments. Methods to identify phases and subphases of the gait cycle are necessary for comprehensive assessment of pathological gait. The current study evaluated the accuracy of a finite state machine (FSM) algorithm to detect strides by identifying gait cycle subphases from ankle-worn accelerometry. Algorithm performance was challenged across a range of speeds (0.4-2.6 m/s), task conditions (e.g., single- and dual-task walking), and individual characteristics. Specifically, the study included a range of treadmill speeds in young adults and overground walking conditions in older adults with neurological disease. Manually counted and algorithm-derived stride detection from acceleration data were evaluated using error analysis and Bland-Altman plots for visualization. Overall, the algorithm successfully detected strides (>96 % accuracy) across gait speed ranges and tasks, for young and older adults. The accuracy of an FSM algorithm combined with ankle-worn accelerometers, provides an analytical approach with affordable and portable tools that permits comprehensive assessment of gait unbounded by setting and proves to perform well in in walking tasks characterized by variable walking. These algorithm capabilities and advancements are critical for identifying phase dependent gait impairments in clinical and free-living assessment.

1 May 2025 in Digital Health
Verified
Journal Article
Open access
FGF Elizabeth Godkin
F Elizabeth Godkin
KOKaren Van Ooteghem
Karen Van Ooteghem
KBKit Beyer
Kit Beyer
KWKyle S. Weber
Kyle S. Weber
BCBenjamin F Cornish
Benjamin F Cornish
WMWilliam E McIlroy
William E McIlroy
Objective: Advances in the collection of high-quality, continuous electrocardiography (ECG) data via wearable technology have the potential to transform heart rate (HR) measurement in daily life. This study aimed to characterize the impact of methodological criteria and behavioral context on estimates of resting heart rate (RHR) to guide recommendations for a standardized approach to measure daily life RHR. Methods: Ten adults (9 female, 61 ± 12 years) wore a chest-mounted ECG device and wrist and ankle movement sensors continuously for 7–10 days. Following signal quality screening and beat-to-beat calculations, HR was analyzed using rolling averages of 15-, 30-, and 60-s windows within periods of device-detected sedentary behavior and sleep. ECG data during sedentary and sleep were compared for differences in: (1) RHR, (2) between-day consistency of daily RHR, and (3) HR median and range. Results: During sedentary and sleep, respectively, there was no difference in RHR (56 ± 7 vs. 54 ± 7 bpm, p = 0.055) or in between-day consistency of RHR (coefficient of variation: 6 ± 3% vs. 5 ± 3%, p = 0.12; maximum between-day range of RHR=14 bpm). However, the median HR (71 ± 6 vs. 62 ± 7 bpm, p = 0.001) and HR range (35 ± 6 vs. 23 ± 7 bpm, p < 0.01) were significantly greater during sedentary versus sleep. Conclusions: Behavioral context and method of analysis impact ECG-based HR measures at rest. This study recommends a novel wearable-based method for measuring daily life RHR that maximizes use of available data and confronts variability that exists with extended monitoring. Use of a standard method for measuring daily life RHR may advance the use of HR to inform clinical and/or personal health decisions.

4 August 2022 in JMIR Preprints
Verified
Preprint
Open access
KWKyle S. Weber
Kyle S. Weber
FGF Elizabeth Godkin
F Elizabeth Godkin
BCBenjamin F Cornish
Benjamin F Cornish
WMWilliam McIlroy
William McIlroy
KOKaren Van Ooteghem
Karen Van Ooteghem
BACKGROUND Accurate measurement of daily physical activity (PA) is important as PA is linked to health outcomes in older adults and people living with complex health conditions. Wrist-worn accelerometers are widely used to estimate PA intensity, including walking, which composes much of daily PA. However, there is concern that wrist-derived PA data in these cohorts is unreliable due to slow gait speed, mobility aid use, disease-related symptoms that impact arm movement, and transient activities of daily living. Despite the potential for error in wrist-derived PA intensity estimates, their use has become ubiquitous in research and clinical application. OBJECTIVE The goals of this work were to (1) determine the accuracy of wrist-based estimates of PA intensity during known walking periods in older adults and people living with cerebrovascular disease (CVD) or neurodegenerative disease (NDD) and (2) explore factors that influence wrist-derived intensity estimates. METHODS A total of 35 older adults (n=23 with CVD or NDD) wore an accelerometer on the dominant wrist and ankle for 7 to 10 days of continuous monitoring. Stepping was detected using the ankle accelerometer. Analyses were restricted to gait bouts ≥60 seconds long with a cadence ≥80 steps per minute (LONG walks) to identify periods of purposeful, continuous walking likely to reflect moderate-intensity activity. Wrist accelerometer data were analyzed within LONG walks using 15-second epochs, and published intensity thresholds were applied to classify epochs as sedentary, light, or moderate-to-vigorous physical activity (MVPA). Participants were stratified into quartiles based on the percent of walking epochs classified as sedentary, and the data were examined for differences in behavioral or demographic traits between the top and bottom quartiles. A case series was performed to illustrate factors and behaviors that can affect wrist-derived intensity estimates during walking. RESULTS Participants averaged 107.7 (SD 55.8) LONG walks with a median cadence of 107.3 (SD 10.8) steps per minute. Across participants, wrist-derived intensity classification was 22.9% (SD 15.8) sedentary, 27.7% (SD 14.6) light, and 49.3% (SD 25.5) MVPA during LONG walks. All participants measured a statistically lower proportion of wrist-derived activity during LONG walks than expected (all P<.001), and 80% (n=28) of participants had at least 20 minutes of LONG walking time misclassified as sedentary based on wrist-derived intensity estimates. Participants in the highest quartile of wrist-derived sedentary classification during LONG walks were significantly older (t16=4.24, P<.001) and had more variable wrist movement (t16=2.13, P=.049) compared to those in the lowest quartile. CONCLUSIONS The current best practice wrist accelerometer method is prone to misclassifying activity intensity during walking in older adults and people living with complex health conditions. A multidevice approach may be warranted to advance methods for accurately assessing PA in these groups. CLINICALTRIAL

25 June 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
ASAishwarya Shenoy
Aishwarya Shenoy
KBKit Beyer
Kit Beyer
WMWilliam McIlroy
William McIlroy
KOKaren Van Ooteghem
Karen Van Ooteghem
KWKyle S. Weber
Kyle S. Weber
CPCourtney L. Pollock
Courtney L. Pollock
In accelerometer-based measurement, inclusion of upper extremity (UE) activity during walking can overestimate real-world functional UE use in people post-stroke. This study introduces a comprehensive, accelerometer-based approach to examine real-world UE use, including contribution of UE activity during walking, and compares UE use during walking versus ADL-based activities. People with subacute stroke wore bilateral wrist and ankle inertial measurement units (IMU) for one week (24 hrs/day). Agreement between UE-Total, UE-Continuous Walking, and UE-ADL measures were assessed using Bland–Altman analyses. Variables were modeled using linear regression to explore step count, mobility aid use and UE motor impairment as predictors of IMU measures of real-world UE use. Agreement between UE-Total and UE-ADL measures showed minimal bias. Differences between UE-Continuous Walking and UE-ADL varied by mobility aid. UE-Continuous Walking was associated with increased UE activity and relatively greater paretic arm use compared with UE-ADL. Across UE-Continuous Walking and UE-ADL, step count was the strongest predictor of real-world UE use. UE activity during continuous walking exhibits different use patterns as compared to ADL-based activity. Accordingly, separating continuous walking-related UE activity from ADL-based UE use may improve clinical interpretation of IMU measures of real-world UE use in individuals with subacute stroke.

3 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ASAishwarya Shenoy
Aishwarya Shenoy
KBKit Beyer
Kit Beyer
WMWilliam McIlroy
William McIlroy
KOKaren Van Ooteghem
Karen Van Ooteghem
KWKyle S. Weber
Kyle S. Weber
CPCourtney L. Pollock
Courtney L. Pollock
In accelerometer-based measurement, the inclusion of upper extremity (UE) activity during walking can overestimate real-world functional UE use in people post-stroke. This study introduces a comprehensive, accelerometer-based approach to examining real-world UE use, including the contribution of UE activity during walking, and compares UE use during walking versus ADL-based activities. People with subacute stroke wore bilateral wrist and ankle inertial measurement units (IMU) for one week (24 h/day). Agreement between UE-Total, UE-Continuous Walking and UE-ADL measures were assessed using Bland–Altman analyses. Variables were modeled using linear regression to explore step count, mobility aid use and UE motor impairment as predictors of IMU measures of real-world UE use. Agreement between UE-Total and UE-ADL measures showed minimal bias. Differences between UE-Continuous Walking and UE-ADL varied by mobility aid. UE-Continuous Walking was associated with increased UE activity and relatively greater paretic arm use compared with UE-ADL. Across UE-Continuous Walking and UE-ADL, step count was the strongest predictor of real-world UE use. UE activity during continuous walking exhibits different use patterns as compared to ADL-based activity. Accordingly, separating continuous walking-related UE activity from ADL-based UE use may improve clinical interpretation of IMU measures of real-world UE use in individuals with subacute stroke.