T M SHAHRIAR SAZZAD

Dr. T M SHAHRIAR SAZZAD

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2025 in Sonography
Verified
Journal Article
Open access
CWCaterina Watson
Caterina Watson
LALeisa Armstrong
Leisa Armstrong
David Francis CookDavid Francis Cook
David Francis Cook
TST M SHAHRIAR SAZZAD
T M SHAHRIAR SAZZAD
NPNayana Parange
Nayana Parange
Surgical subspecialties have successfully combined robotic technology with traditional practices. In doing so, they have benefited from increased precision in techniques, reduced incidence of surgical complications, and reduced MSK disorders. This scoping review aims to examine the extent of cobotics in obstetric ultrasound. The review was conducted using the JBI PRISMA protocol to map the topic of robotics in obstetric ultrasound. Teleoperated remote ultrasound formed the largest combined clinical cohort of 67 patients. Limitations of the 20‐week scan concerned incomplete visualization of fetal structures. These included cavum septi pellucidi, cardiac outflow tracts, kidneys, lips and spine. Third trimester scans omitted umbilical artery Doppler measures. Patients having telerobotic ultrasound report the experience as “comfortable” and would agree to repeat the robotic scan in the future. Obstetric cobotic literature was found to focus on the following subtopics: robotic‐assisted ultrasound, automated image acquisition, image stitching and fusion, teleoperated remote ultrasound, and ultrasound‐guided robotic surgery. Ultrasound‐guided robotic surgery was performed for maternal partial nephrectomy and cervical cerclage. The most mature application of obstetric cobotics is seen in teleoperated remote ultrasound, where pilot trials have used clinical patients. Other areas are early in the research phase, with investigation for proof of concept testing.

16 July 2026 in Health Information Science and Systems
Verified
Journal Article
Closed access
MTMayesha Tasnim
Mayesha Tasnim
SDSejuty Das
Sejuty Das
STShafee Shadman Tonoy
Shafee Shadman Tonoy
TST M SHAHRIAR SAZZAD
T M SHAHRIAR SAZZAD

30 June 2026 in MIST INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLOGY
Verified
Journal Article
Open access
MMMohammad Shahjahan Majib
Mohammad Shahjahan Majib
FAFaysal Ahmed
Faysal Ahmed
TST M SHAHRIAR SAZZAD
T M SHAHRIAR SAZZAD
MRMd. Mamun Or Rashid
Md. Mamun Or Rashid
MHMd. Ashraful Haque
Md. Ashraful Haque
Brain tumors are the most fatal diseases of the central nervous system. Accurate, early MRI classification can support timely clinical decisions and treatment planning. This study systematically identifies an effective and efficient hybrid architecture combining Convolutional Neural Networks (CNNs) and Vision Transformers (ViTs) for multi-class brain tumor classification from 2D MRI images through a systematic screening evaluation. In this study, 12 CNN–Transformer pairs were evaluated under an identical training procedure using the original Kaggle train/test split. A late-concatenation fusion of DenseNet-121 and Swin-Tiny yielded the highest Kaggle testing accuracy of 94.38% during the screening stage. To provide a more reliable and fair comparison, a 10-fold stratified Cross-Validation (CV) was conducted on the Kaggle Training set only. The best-ranked pair was EfficientNet-B0 + Swin-Tiny, achieving a mean CV accuracy of 98.29% ± 0.55% with selective fine-tuning. The final model was trained on the Kaggle Training set, evaluated on the Kaggle Testing set, and tested on an independent external dataset (TEST2). The final model achieved 93.94% accuracy on the Kaggle Test Set and 87.21% accuracy on TEST2. The result indicates a notable domain shift under external validation. In addition, paired statistical significance tests among top model pairs, ablation studies on the fusion strategy and trainable ratio, and computational cost analysis (training time, inference latency, GPU memory, and parameter counts) are reported.

21 September 2026 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
MMMohammad Shahjahan Majib
Mohammad Shahjahan Majib
MOMd. Mamun Or-Rashid
Md. Mamun Or-Rashid
MHMd. Ashraful Haque
Md. Ashraful Haque
FAFaysal Ahmed
Faysal Ahmed
TST M SHAHRIAR SAZZAD
T M SHAHRIAR SAZZAD
Many existing deep-learning models for brain-tumor diagnosis report very high accuracy, yet they often suffer from overfitting, limited generalizability, and poor robustness, which reduces their clinical reliability. First, a large and diverse dataset was assembled from multiple publicly available sources to reduce data bias. Next, a series of regularization and calibration techniques were applied, including label smoothing, mixup augmentation (α=0.4), exponential moving average (EMA) of model weights to prevent overfitting, stabilize training, and temperature scaling to calibrate predicted probabilities. Since brain-tumor diagnosis directly affects critical clinical decisions, both model accuracy and reliability of its predictions are essential. For that, six diverse, powerful pretrained backbones (ConvNeXt, EfficientNetV2, DenseNet201, Swin, ViT, and DINOv3) were used as frozen feature extractors under pure transfer learning. On top of these frozen features, lightweight classification heads were trained using concatenation, attention, and gated fusion. Then, the predicted-class probabilities from the selected heads were combined and passed to a logistic-regression meta-learner to produce the final prediction, with the aim of improving accuracy and reliability. This architecture is computationally efficient because only lightweight classifiers and a logistic meta-learner are trained, while the heavy backbones remain frozen. The best-performing variant on TEST2, attn_fp_ens, was further evaluated using synchronized 10-fold cross-validation on the TRAIN set. The best-performing TEST variant, the gated-fusion ensemble with fingerprint features (gated_fp_ens), achieved 99.33% test accuracy and 99.28% macro-F1. Under domain shift on the external hospital dataset (TEST2), the attention-fusion ensemble with fingerprint features (attn_fp_ens) showed the strongest performance among the evaluated variants, achieving 95.16% accuracy and 94.11% macro-F1. The TEST2 dataset was collected from a local hospital for external evaluation.