Anterior cruciate ligament (ACL) lesion represents one of the most dramatic sport injuries. Even though clinical screenings aiming at identifying subjects at risk of injuries are gaining popularity, the use of sophisticated equipment still represents a barrier towards their widespread use. This study aimed to test both reliability and repeatability of a new methodology to assess lower limb joints kinematics and kinetics directly on field with the aid of video cameras and plantar pressure insoles. Ten athletes and one case study (post ACL surgery) were assessed in a gait laboratory, while performing double leg squats, through the simultaneous acquisition of stereophotogrammetry, force plates, commercial video cameras and plantar pressure insoles. Different sources of errors were investigated and both reliability and repeatability analysis performed. Minimum and maximum RMSE values of 0.74% (right knee joint center trajectory) and 64.51%, respectively (ankle dorsi-plantarflexion moment), were detected. Excellent to good correlation was found for the majority of the measures, even though very poor and inverse between-trials correlation was found on a restricted number of trials especially for the ankle dorsi-plantarflexion moment. These findings could be used in combination with already available screening tools in order to provide more repeatable results.
Background: Work-related musculoskeletal disorders pose a significant burden on the population. The OCRA method plays a key role in assessing the risk associated with repetitive actions of the upper limbs. In this method, muscular force is evaluated based on the rate of perceived effort (RPE) reported by the worker, which can introduce subjective bias into the assessment. This study aims to determine whether testing the worker’s handgrip strength can improve the accuracy of the force assessment in the OCRA method. Methods: Handgrip strength was measured during the risk assessment process following the OCRA method. Data were divided into specific percentile ranks based on age, gender, height, and handedness. Results: 903 workers from 43 different Italian companies were surveyed. There was a significant difference in handgrip strength percentiles stratified by report of an RPE > 2 and those without (p = 0.047). Additionally, significant differences were found in perceived effort rates (based on the OCRA method) among workers with different levels of stratified handgrip strength (dominant hand: p = 0.04, non-dominant hand: p = 0.02). Conclusions: Workers performing repetitive upper limb actions at various strength levels experience different perceived effort rates during tasks. These findings suggest that measuring handgrip strength is a crucial component of risk assessments using the OCRA method. To date, this study's sample size is among the largest for this evaluation method; we believe these results could be a significant step forward in improving the risk assessment process for biomechanical overload
Background/Objectives: Mechanical shocks generated by the recoil of hand-held power screwdrivers are a significant biomechanical stressor for the operator’s hand–arm complex. Currently, vibration exposure is measured at the tool-handle level, while operator-centered practical measures remain limited. This study proposes a computational methodology to quantify relative reductions in mechanical shock and biomechanical load across different workstations. Using wearable inertial measurement units, ratios of transmitted torque and worst-case wrist joint power were calculated directly at the operator’s upper limb, without direct force measurement. Methods: The methodology was tested with 30 participants performing standardized fastening tasks across five configurations: one unsupported and four with distinct support arms, paired with an electric and pneumatic in-line screwdriver. Results: Workstation configuration had a significant main effect on both the peak angular acceleration and the peak wrist angular velocity (p < 0.001 for both variables). Compared with the unsupported condition, all support-arm configurations substantially reduced the mechanical shock transmitted to the operator, decreasing the estimated transmitted torque by 71–81% and the worst-case wrist joint power by more than 95% (p < 0.001 for all pairwise comparisons). The articulated arm induced higher kinematic responses than telescopic and Cartesian designs. Age was the only significant covariate for hand peak angular acceleration (p = 0.039). Conclusions: The proposed methodology provides a simplified operator-centered approach for assessing mechanical shock transmission during screwdriving operations using wearable IMUs. This methodology may serve as a preliminary screening tool to support workstation design and ergonomic investigations. However, the present findings do not establish a direct relationship between the proposed indices and musculoskeletal disorder risk, and further validation against established ergonomic and clinical outcomes is required.