Giovanni Grillo

Dr. Giovanni Grillo

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
NFNúria Fernández‐Poch
Núria Fernández‐Poch
FFFerran Fillat‐Gomà
Ferran Fillat‐Gomà
MGMireia Gamundi
Mireia Gamundi
GGGiovanni Grillo
Giovanni Grillo
CYChristian Yela‐Verdú
Christian Yela‐Verdú
XPXavier Pelfort
Xavier Pelfort
Purpose: Current surgical methods for multi‐ligament knee reconstruction involve the creation of several reconstruction tunnels in the distal femur. However, the limited bone mass in the knee increases the risk of tunnel convergence. Increasing the accuracy of tunnel direction can minimize tunnel collision during anatomical reconstruction. 3D‐printed patient‐specific instrumentation (PSI) has gained prominence in orthopaedic surgery due to its precision. This study aims to compare the accuracy of PSI with that of the ‘freehand’ approach by an experienced surgeon for drilling the medial and lateral femoral tunnels while adhering to the recommended angulations for multi‐ligament knee injuries.Methods: Ten cadaveric knees underwent computerized tomography (CT) scans to identify anatomical femoral attachments of the lateral collateral ligament (LCL), popliteal tendon (PT), medial collateral ligament (MCL) and posterior oblique ligament (POL). Using Materialise Mimics Medical v25.0 software, virtual planning of a bone tunnel for each ligament was performed, and a total of four tunnels per knee were obtained. Ten PSIs were designed for five knees: five for the medial side and five for the lateral side. The first five knees were operated on via PSI, and the other five knees were operated on by an experienced surgeon using freehand drilling based on preoperative plans. The angular deviation and entry point were assessed by overlaying post‐operative CT images onto preoperative CT images.Results: In the freehand group, the median angular deviation was 22.3°, with an interquartile range (IQR) of 17.6–25.2°. The PSI group presented a significantly greater accuracy in angular deviation for femoral tunnels of 5.7°, with an IQR of 4–8.2° (p < 0.001). Compared with that in the preoperative planning group, the median entry point distance in the freehand group was 5.5 mm, with an IQR of 2.6–8.8 mm. The PSI group had a median entry point distance of 4.2 mm, with an IQR of 3.6–5.7 mm (p = n.s).Conclusions: Compared with the freehand technique performed by an experienced surgeon, PSI demonstrated significantly greater accuracy in terms of the mean angular deviation.Level of Evidence: Level V.

23 June 2023
Verified
Journal Article
Closed access
DMDomenico De Mauro
Domenico De Mauro
ACAlessandra Cicia
Alessandra Cicia
MMMaria Concetta Meluzio
Maria Concetta Meluzio
GGGiovanni Grillo
Giovanni Grillo
ASAmarildo Smakaj
Amarildo Smakaj
FTFrancesco Ciro Tamburrelli
Francesco Ciro Tamburrelli

14 October 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
GGGiovanni Grillo
Giovanni Grillo
ALAlexandre Coelho Leal
Alexandre Coelho Leal
DMDavid Martí
David Martí
MTMarçal Pineda Tortajada
Marçal Pineda Tortajada
SGSergi Gil-Gonzalez
Sergi Gil-Gonzalez
XLXavier Pelfort Lopéz
Xavier Pelfort Lopéz
Objective: To evaluate inter-surgeon variability in mediolateral joint balance assessment during robotic-assisted total knee arthroplasty (TKA) using the robotic surgical assistant (ROSA) Knee System, and to determine whether such variability influences the surgical planning generated by this system. Methods: An observational study was conducted including 101 patients undergoing primary robotic-assisted TKA. Two experienced surgeons independently assessed intraoperative mediolateral laxity by manually applying varus–valgus stress across six predefined flexion angles (0°, 30°, 45°, 60°, 90°, and 120°). Measurements of medial and lateral gaps (mm) and varus–valgus alignment (°) were recorded using the ROSA Knee System. Inter-observer differences were analysed using the Wilcoxon signed-rank test, and reliability was assessed using the intraclass correlation coefficient (ICC). The impact of inter-surgeon variability on surgical planning, including bone resection and compartmental space measurement parameters, was also evaluated. Results: No statistically significant inter-observer differences were observed in mediolateral gap measurements or varus–valgus alignment across all flexion angles (p > 0.05). Inter-observer reliability for varus–valgus measurements was good to excellent in extension and early flexion (ICC 0.86–0.91), decreased to moderate at 90° (ICC 0.68–0.74) and was poor for varus assessment at 120° (ICC 0.46, 95% CI 0.29–0.60). For gap measurements, reliability was excellent for the medial gap and good for the lateral gap in extension (ICC 0.93 and 0.89, respectively), and moderate for both gaps at 90° (ICC 0.71–0.74). No significant inter-observer differences were found in cut or space measurements, with excellent agreement for cut parameters (ICC > 0.95). Conclusions: Inter-surgeon assessment of mediolateral joint balance during robot-assisted TKA showed good-to-excellent reproducibility in extension and early flexion, with reduced reproducibility in deep flexion. Statistically significant inter-observer differences were not observed in the resulting cut and space measurements.