Dubhaltach Mac Lochlainn

Mr. Dubhaltach Mac Lochlainn


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
AWAnthony Joseph Weir
Anthony Joseph Weir
DLDubhaltach Mac Lochlainn
Dubhaltach Mac Lochlainn
HMHelio Musselwhite-Veitch
Helio Musselwhite-Veitch
GDGerard Dooly
Gerard Dooly
DDDinesh Babu Duraibabu
Dinesh Babu Duraibabu
This paper presents a proof-of-concept investigation into a novel hermetically sealed tunable-medium Extrinsic Fabry–Pérot Interferometer (EFPI) temperature sensor architecture. A series of tuneable-sensitivity EFPI temperature sensors is demonstrated, comprising a large-diameter fused silica diaphragm with a 800 μm diameter, significantly exceeding conventional designs (typically ∼125 μm), with polished diaphragm thicknesses ranging from 28 to 49 μm, housed in hermetically sealed rigid melting point capillaries with a 1.8 mm internal diameter. By exploiting thermally induced pressure differentials generated by a tunable Krytox GPL 105 oil/air fill fraction within the sealed rigid cavity, the sensors demonstrate a continuously tuneable sensitivity design space spanning 0.45 to 190 nm/K. An exact nonlinear thermal pressure model is derived and validated, replacing the linearised approximation which is shown to be inapplicable at fill fractions approaching unity. The low-sensitivity configuration (0.45 nm/K) was characterised at the National Standards Authority of Ireland (NSAI) National Metrology Laboratory against ITS-90 fixed points: the Triple Point of Water (273.16 K) and the Gallium Fixed Point (302.9146 K), with traceability to the International Temperature Scale of 1990 (ITS-90), yielding an instrument-limited resolution of <1.1 mK, consistent with the metrological validation environment. The high-sensitivity configurations (21 and 190 nm/K) were characterised on a laboratory bench, achieving instrument-limited theoretical resolutions of <24 μK and <2.6 μK respectively, pending future metrological validation. The 190 nm/K sensitivity represents an improvement of approximately 21.7× over the closest directly comparable prior Citationutilised fusion splicing and manual polishing. Future development priorities include metrological validation of the high-sensitivity configurations, long-term stability characterisation, thermal cycling, and progression towards an all-glass hermetically sealed construction.

28 February 2017 in International Journal "Advanced Quality"
Verified
Journal Article
Open access
PDF file
JFJean-Rémy Filitz
Jean-Rémy Filitz
NANarcisa Arifovic
Narcisa Arifovic
MSMohamed Sadli
Mohamed Sadli
GFGuillaume Failleau
Guillaume Failleau
BHBruno Hay
Bruno Hay
DZDavor Zvizdić
Davor Zvizdić
This paper deals with a new European project in which the overall objective is to enhance the availability of facilities in the field of thermal metrology (e.g. high temperature contact thermometry, non-contact thermometry and thermo-physical properties of materials characterisation) in European emerging National Metrology Institutes (NMIs), where access to these types of facilities is currently limited.