Gregory Gabuzov

Mr. Gregory Gabuzov

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2026 in Comorbidity neurology
Verified
Journal Article
Closed access
SKS.V. Kotov
S.V. Kotov
AKA.A. Kondur
A.A. Kondur
ESE.V. Slyunkova
E.V. Slyunkova
PBPavel Bobrov
Pavel Bobrov
BDBobrov Dmitry
Bobrov Dmitry
DSDmitriy Shagin
Dmitriy Shagin
INTRODUCTION. The use of neurotechnology, the brain–computer interface (BCI), based on the motor imagery (MI), occupies one of the leading places in terms of effectiveness in neurorehabilitation. At the same time, various types of feedback in the BCI system are being developed and actively used in the rehabilitation process. The feedback targets the visual, proprioceptive, or auditory sensory system, and may employ a multimodal approach depending on the rehabilitation paradigm. Much attention of researchers is attracted to using touch, sensation of touch, force, and vibration as reinforcement signals via haptic feedback technology AIM. To evaluate the effectiveness of the integration of haptic biofeedback into BCI technology in patients with arm paresis in the recovery period after a stroke. MATERIALS AND METHODS. Eighteen patients suffering from chronic stroke (5 females and 13 males) participated in the study. The patients participated in motor imagery BCI trainings and were split into two groups according to the feedback type. The first group (9 patients, age 59,2 ± 10,6, time since stroke 10,4 ± 2,3 month) received haptic feedback via vibrating stimulation of palm surface and the second group (9 patients, age 59,2 ± 10,6, time since stroke 12 ± 9,8 month) received proprioceptive feedback via palm opening actuation with a robotic actuator. All patients received pharmacological therapy as part of secondary stroke prevention; rehabilitation interventions included therapeutic exercise, physiotherapy procedures, massage, and speech therapy sessions. RESULTS AND DISCUSSION. In group 1, motor function improved according to the Fugl-Meyer (FM), ARAT scales from 18 [14; 24] to 30 [20;30], with 2[1; 5] 3 [2; 8] points, respectively. In the 2nd group from 20 [17; 23] to 23[19; 27] on the FM scale, from 2 [1; 6] to 4 [3; 8] points on the ARAT scale. If we consider the 1st group as a "case" and the 2nd as a "control", then after adjusting for the initial FM (ANCOVA), we obtained a difference in the indicator (Δ) of the FM scale of 3.2 points (p = 0.046). The data obtained also demonstrates that BCI with vibrating rings is superior to BCI controlled by an exoskeleton in restoring motor functions, even with a pairwise comparison of similar patients. CONCLUSION. The use of BCI technology based on MI in combination with biofeedback in the form of vibration stimulation of the palm surfaces of the hands is a new promising method of rehabilitation of patients with severe hemiparesis after a stroke. KEYWORDS: brain–computer interface, biofeedback, exoskeleton, vibrational stimulation, rehabilitation after stroke, post-stroke hemiparesis

7 March 2026 in Sechenov Medical Journal
Verified
Journal Article
Open access
PDF file
SZS. K. Zazulin
S. K. Zazulin
STS. M. Titkova
S. M. Titkova
MAMichael Anurov
Michael Anurov
GGGregory Gabuzov
Gregory Gabuzov
ECE. Yu. Chizh
E. Yu. Chizh
АBА. E. Brovkin
А. E. Brovkin
Aim . To develop and validate a test setup for measuring the load under compression elements (CE) of multilayer bandages composed of materials with different stiffness. Materials and methods . Prototypes of multilayer bandages were fabricated in the laboratory by combining three types of CEs (foam polymer and dense nonwoven viscose material) with three types of fixing fabrics (FF) based on polyester and viscose/polyester. The test setup consisted of an upper-limb model made of rigid plastic covered with artificial skin and a block with two strain‑gauge sensors that recorded the load in gram-force (gf) under the CE area and in a control zone without a CE at an external pressure of 40 mmHg. For each CE–FF combination, 10 repeated measurements were performed in two regions of the sample (60 values per sensor per group), and the data were analysed using nonparametric statistical tests. Results . The load under the CE differed significantly between groups ( p < 0.001) and depended on the type and stiffness of the material: the median load under type 3 CE with the highest stiffness was 259.4 (252.6; 263.3) gf, whereas under type 1 CE with the lowest stiffness it was 149.9 (145.1; 171.9) gf. Type 2 CE produced intermediate values of 241.7 (206.4; 259.3) gf. Testing of the FFs also showed statistically significant differences in pressure in the absence of a CE ( p < 0.001): the highest load was recorded under type 2 FF (viscose/polyester) at 141.0 (140.2; 142.1) gf, and the lowest under type 1 FF made of polyester with higher surface density at 14.5 (14.3; 15.6) gf; type 3 FF provided an intermediate level of 65.7 (64.9; 69.3) gf. Conclusion . The developed in vitro setup shows high sensitivity to differences in CE stiffness and FF properties and can be used as a screening tool for quantitative comparative assessment of multilayer bandage prototypes with locally differentiated compression areas prior to in vivo studies.

1 August 2026 in Human Physiology
Verified
Journal Article
Closed access
PDF file
MKM. E. Kurgansky
M. E. Kurgansky
AKA. V. Kurgansky
A. V. Kurgansky
IFI. R. Fedotova
I. R. Fedotova
GGGregory Gabuzov
Gregory Gabuzov
MIMikhail Isaev
Mikhail Isaev
PBPavel Bobrov
Pavel Bobrov
We examined cortical interactions in 13 participants during kinesthetic imagery of hand closing and opening accompanied by passive movement congruent or incongruent with the imagined movement. The strength of effective intracortical connectivity was estimated using the directed transfer function. Passive movement altered the strength of effective (directed) connectivity between EEG signals recorded over primary and medial secondary regions of the sensorimotor cortex; the changes were most pronounced in the β frequency band. The response to passive movement differed between imagery of hand closing and hand opening. Although the strength of directed connectivity changed under both congruent and incongruent conditions, the changes were greater when passive and imagined movements were in opposite directions.

4 September 2026 in Sensors
Verified
Journal Article
Open access
PDF file
OMOlesya Mokienko
Olesya Mokienko
ELEvgeniy Lukyanov
Evgeniy Lukyanov
Leonid KimLeonid Kim
Leonid Kim
MIMikhail Isaev
Mikhail Isaev
GGGregory Gabuzov
Gregory Gabuzov
PBPavel Bobrov
Pavel Bobrov
Among the various brain–computer interface (BCI) modifications used in post-stroke rehabilitation, BCI systems combined with functional electrical stimulation (FES) are considered the most effective. As a preliminary step toward optimizing such systems for clinical application, it remains unclear whether using electroencephalography (EEG) alone versus a hybrid EEG and functional near-infrared spectroscopy (fNIRS) approach affects real-time three-class BCI–FES control performance in healthy individuals. In a blind randomized study, 16 healthy volunteers completed five BCI–FES training sessions across three days. In one group, FES of wrist extensor muscles was driven by a hybrid EEG–fNIRS classifier; in the other, by EEG only. Classification accuracy, sense of agency, attention, and physical comfort were assessed. No statistically significant between-group differences were found in any outcome measure (p > 0.05). Median real-time three-class classification recall was 53.5% in the hybrid group and 57.3% in the EEG-only group. The median agency score reached approximately 75% of the maximum possible value in both groups. Simulation analysis showed comparable accuracy for unimodal fNIRS-only and EEG-only classifiers. Genetic algorithm-based channel selection identified C3 and C4 as the most informative EEG channels, while optimal fNIRS placement required individual optimization. Within the constraints of the classification and fusion pipeline used here, these findings suggest that signal acquisition modality does not significantly influence BCI–FES performance or sense of agency in healthy subjects. The complete EEG–fNIRS dataset is publicly available through NITRC.

13 November 2026 in Journal of Motor Behavior
Verified
Journal Article
Closed access
MKMarina E. Kurgansky
Marina E. Kurgansky
AKAndrey V. Kurgansky
Andrey V. Kurgansky
MIMikhail Isaev
Mikhail Isaev
IFIrina R. Fedotova
Irina R. Fedotova
GGGregory Gabuzov
Gregory Gabuzov
PBPavel Bobrov
Pavel Bobrov