Zhen Gong

Dr. Zhen Gong

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2022 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
ZGZhen Gong
Zhen Gong
CLChengxi Liu
Chengxi Liu
LSLei Shang
Lei Shang
QLQiupin Lai
Qiupin Lai
YTYacine Terriche
Yacine Terriche
The grid voltage modulated direct power control (GVM-DPC)-based inverter is an attractive solution to regulate the instantaneous real and reactive powers injected into power grids. However, the power coupling in GVM-DPC, i.e., interactions between the real and reactive power loops, may deteriorate its transient performance. In this paper, a power decoupling strategy for GVM-DPC is proposed based on a dynamic feedforward power compensation (DFPC) algorithm. It is proved that the proposed strategy has better decoupling performance than that of the traditional virtual impedance method (VIM). Firstly, power coupling characteristics in GVM-DPC are analyzed, indicating that the ignorance of voltage angle variation at the point of common coupling (PCC) will result in severe power coupling. Then, power coupling magnitudes are derived according to relationships among the real power, reactive power and PCC voltage. Next, the coupling magnitudes are compensated into the power control loop of the GVM-DPC for the better decoupling performance. The transient performance of inverter using DFPC is studied based on the impedance analysis. Also, the relationship between coupling magnitude and grid side impedance is studied, which indicates the limited power decoupling capability of VIM. Finally, the proposed method is validated by the simulations and a hardware-in-loop system.

8 November 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZGZhen Gong
Zhen Gong
CLChengxi Liu
Chengxi Liu
Yonghao GuiYonghao Gui
Yonghao Gui
FSFilipe Faria da Silva
Filipe Faria da Silva
Claus Leth BakClaus Leth Bak
Claus Leth Bak
The grid voltage modulated direct power control (GVM-DPC) is a novel power regulation method for grid-connected voltage source inverters (VSI). However, interactions between real and reactive powers still exist in GVM-DPC under unbalanced grid voltage condition, which may deteriorate its transient performance. This article proposes a power decoupling method for GVM-DPC-based VSI in unbalanced systems based on the dynamic feedforward power compensation strategy, which can reduce the coupling magnitudes of real and reactive powers in the transient stages. First, the power coupling mechanism of positive and negative sequence real and reactive powers of VSI under the unbalanced voltage condition is analyzed. Then, the power coupling magnitudes (PCM) are derived according to relationships among the positive sequence components of real power, reactive power and point of common coupling (PCC) voltages. Next, the PCM are compensated into the GVM-DPC for the better decoupling performance. Furthermore, a stability analysis of the proposed control system is studied based on the impedance model, and a comparison with the traditional power decoupling method based on virtual impedance is conducted to show the superiority of the proposed method. Finally, simulations, hardware-in-loop test and experiment are conducted to validate the effectiveness of the proposed method.

9 June 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KSKaiyuan Su
Kaiyuan Su
XXXiaorong Xie
Xiaorong Xie
ZGZhen Gong
Zhen Gong
HLHui Liu
Hui Liu
DSDawei Sun
Dawei Sun
YWYaohan Wang
Yaohan Wang
The fast frequency response (FFR) provided by the battery energy storage system (BESS) is essential for maintaining the frequency stability of a power system. However, the voltage coupling effect (VCE) may negatively affect the FFR of the BESS in weak grids. The VCE, particularly when comparing grid-following (GFL) and grid-forming (GFM) control strategies, remains inadequately explored. This paper proposes a novel FFR modeling approach for the GFL & GFM BESS considering the VCE. The impacts of BESS converter parameters and system characteristics on the VCE are investigated. Comparative analyses between GFL & GFM control are performed to quantify the VCE differences and identify critical parameters affecting the VCE on the FFR. The proposed models and analyses are validated through electromagnetic transient simulations and control-hardware-in-the-loop (CHIL) experiments. It is revealed that the VCE emerges from the instantaneous voltage drop during step disturbances, leading to reduced active power support and delayed frequency recovery. The VCE increases significantly as the short circuit ratio (SCR) approaches 2, but can be mitigated through increased voltage droop coefficients or, in GFM control, through adjusting virtual impedance. With appropriately selected parameters, the GFM BESS demonstrates superior performance in weak grids with reduced capacity requirements compared to GFL BESS.

3 July 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZGZhen Gong
Zhen Gong
XXXiaorong Xie
Xiaorong Xie
CLChengxi Liu
Chengxi Liu
Yonghao GuiYonghao Gui
Yonghao Gui
FSFilipe Faria da Silva
Filipe Faria da Silva
MLMingyuan Liu
Mingyuan Liu
Synchronous reference frame-based vector control (SRF-VC) is widely adopted by single stage photovoltaic (PV) inverter to transfer powers into power grids. However, the overshoot effect and power coupling in SRF-VC, i.e., real and reactive powers coupling (RRPC), may cause oscillation amplification and forced oscillation issues when interharmonics of real power reference (Pref) occur, which is induced by Maximum Power Point Tracking (MPPT) control. In this paper, a frequency domain analytical model is proposed to analyze the effect of overshoot and RRPC on forced oscillation when there is an oscillation source of Pref induced by MPPT. Firstly, interharmonics of Pref induced by MPPT is introduced, which can be the oscillation source of forced oscillation. Then, the power coupling mechanisms of SRF-VC are analyzed by visual phasor diagram, which is induced by slow dynamics of PLL in weak grids. Next, the frequency domain model considering RRPC channels are derived to analytically analyze its oscillation amplification characteristics when Pref at sub/super-synchronous resonance frequency occur. Furthermore, forced oscillation magnitudes influenced by different control parameters are investigated by bode diagram of the proposed frequency domain model. Finally, the influences of overshoot and RRPC on forced oscillation are validated by the simulations and control-hardware-in-loop tests.

1 June 2016 in Journal of Wuhan University of Technology-Mater. Sci. Ed.
Verified
Journal Article
Closed access
PDF file
ZGZhen Gong
Zhen Gong
YZYimin Zhang
Yimin Zhang
YHYoujian Hu
Youjian Hu
YYYan Yu
Yan Yu
YYYanbin Yuan
Yanbin Yuan
Hua LiHua Li
Hua Li

4 January 2022 in IET Circuits, Devices & Systems
Verified
Journal Article
Open access
PDF file
CLChengxi Liu
Chengxi Liu
ZGZhen Gong
Zhen Gong
FSFilipe Faria da Silva
Filipe Faria da Silva
QLQiupin Lai
Qiupin Lai
PHPan Hu
Pan Hu
Severe harmonics propagation in power systems may result in increased power losses and equipment damages. In this paper, an elliptic formula is derived to analyse the harmonic spatial distribution not only at the substations but also along the power lines or cables and to give a system‐wide overview of harmonic levels. It is observed that harmonic distortion along power lines can be higher than that at the busbars and the maximum amplitude of harmonic voltage and current denoted as weak positions along power lines depends on the steady‐state harmonic angle difference of voltage and current at busbars, the length of power lines, and the harmonic order. All cases are modelled in detail by analytical geometry and analysed in MATLAB. In this regard, a method to identify the weak positions in terms of maximum harmonic levels in a power system is presented, and its corresponding harmonic orders are determined. The accuracy of the model is tested using time‐domain simulations in PSCAD/EMTDC.