Qi Yu

Qi Yu


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2009 in Indoor Air
Verified
Journal Article
Closed access
PDF file
XGX. Gao
X. Gao
QYQi Yu
Qi Yu
QGQ. Gu
Q. Gu
YCY. Chen
Y. Chen
KDK. Ding
K. Ding
LCL. Chen
L. Chen
In this study, we are trying to investigate the indoor air pollution and to estimate the residents' pollution exposure reduction of energy altering in rural Tibet. Daily PM(2.5) monitoring was conducted in indoor microenvironments like kitchen, living-room, bedroom, and yard in rural Tibet from December 2006 to March 2007. For kitchen air pollution, impact of two fuel types, methane and solid biomass fuels (SBFs), were compared. Questionnaire survey on the domestic energy pattern and residents' daily activity pattern was performed in Zha-nang County. Daily average PM(2.5) concentrations in kitchen, living-room, bedroom, and yard were 134.91 microg/m(3) (mean, n = 45, 95%CI 84.02, 185.80), 103.61 microg/m(3) (mean, n = 21, 95%CI 85.77, 121.45), 76.13 microg/m(3) (mean, n = 18, 95%CI 57.22, 95.04), and 78.33 microg/m(3) (mean, n = 34, 95%CI 60.00, 96.65) respectively. Using SBFs in kitchen resulted in higher indoor pollution than using methane. PM(2.5) concentrations in kitchen with dung cake, fuel wood and methane use were 117.41 microg/m(3) (mean, n = 18, 95%CI 71.03, 163.79), 271.11 microg/m(3) (mean, n = 12, 95%CI 104.74, 437.48), and 46.96 microg/m(3) (mean, n = 15, 95%CI 28.10, 65.82) respectively. Family income has significant influence on cooking energy choice, while the lack of commercial energy supply affects the energy choice for heating more. The effects of two countermeasures to improve indoor air quality were estimated in this research. One is to replace SBFs by clean energy like methane, the other is to separate the cooking place from other rooms and by applying these countermeasures, residents' exposure to particulate matters would reduce by 25-50% (methane) or 20-30% (separation) compared to the present situation. Indoor air pollution caused by solid biomass fuels is one of the most important burdens of disease in the developing countries, which attracts the attention of environment and public health researchers, as well as policy makers. This paper gives a pilot research on the indoor air pollution and estimated the effects of some intervention policies in Tibet of China, where the living habits of the residents are quite different from other parts of the world. This work would be an important supply to the indoor air pollution studies, and would be helpful in policy making.

1 September 2009 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
QYQi Yu
Qi Yu
YZY. Zhang
Y. Zhang
XWX. Wang
X. Wang
WMW.C. Ma
W.C. Ma
LCL.M. Chen
L.M. Chen

SBShubin Bai
Shubin Bai
Yuanqiao WenYuanqiao Wen
Yuanqiao Wen
LHLi He
Li He
YLYiming Liu
Yiming Liu
Yan ZhangYan Zhang
Yan Zhang
MWMa Weichun
Ma Weichun
To study the impact of vessel pollution on the atmospheric environment of the surrounding area, we present a numerical simulation method based on regional emissions inventories. The general spatial resolution is ≥1 km and the temporal resolution is ≥1 h; parameters which are suitable for the study of larger space–time scales. In this paper, the WRF/CALMET/CALPUFF model and Automatic Identification System (AIS) data are employed to develop a single-vessel atmospheric pollution diffusion model. The goal of this research uses existing meteorological models and diffusion models to provide a simulation technology method for studying the diffusion of SO2 from a single ship. We take the outgoing phase of ocean-going container vessels in Yantian Port as an example. It can be used to set the position of sensitive receptors near the port area. Simulations are implemented with CALPUFF and the results are compared with data derived from on-site monitoring instrument. The CALPUFF modelling domain covers an area of 925 km2 with a grid spacing of 500 m. The simulation results demonstrated agreement with the measured data. The ground concentration contribution value ranged from 10 to 102 μg/m3, while the affected area was about 4–26 km2 and the high-value area of the ground concentration contribution was distributed within 1–2 km from the ship track. Emissions generated by the vessels represent a considerable contribution to SO2 pollution around the harbor areas.

2 June 2017 in Atmosphere
Verified
Journal Article
Open access
PDF file
YWYuan Wang
Yuan Wang
ZHZIHAN HUANG
ZIHAN HUANG
YLYujie Liu
Yujie Liu
QYQi Yu
Qi Yu
MWMa Weichun
Ma Weichun
Many researchers have failed to utilize back-calculation to estimate traffic emissions effectively or have obtained unclear results. In this study, the back-calculation of traffic-related PM10 emission factors based on roadside concentration measurements was analyzed. Experimental conditions were considered to ensure the success of back-calculation. Roadside measurements were taken in a street canyon in Shanghai, China. Concentrations from a background site were often found to exceed the measured concentrations at the roadside on polluted days as more errors occurred in the background concentrations. On clean days, these impacts were negligible. Thus, only samples collected on clean days were used in back-calculation. The mean value from back-calculation was 0.138 g/km, which was much smaller than the results obtained using official emission models. Emission factors for light-duty vehicles (LDV), medium-duty vehicles (MDV), heavy-duty vehicles (HDV), and motorcycles were approximately 0.121, 0.427, 0.445, and 0.096 g/km, respectively. The fleet-averaged non-exhaust emission factor was approximately 0.121 g/km, indicating that road dust accounted for 87.7% of the roadside concentration increments. According to the dispersion simulation of reserved samples, the concentrations simulated using back-calculated emission factors were in better agreement with the measured data than the concentrations derived using modeled emission factors.

11 June 2019 in Atmosphere
Verified
Journal Article
Open access
PDF file
ZHZIHAN HUANG
ZIHAN HUANG
QYQi Yu
Qi Yu
YLYujie Liu
Yujie Liu
MWMa Weichun
Ma Weichun
LCLimin Chen
Limin Chen
Dense air quality monitoring network (AQMN) is one of main ways to surveil industrial air pollution. This paper is concerned with the design of a dense AQMN for H2S for a chemical industrial park in Shanghai, China. An indicator (Surveillance Efficiency, SE) for the long-term performance of AQMN was constructed by averaging pollution detection efficiency (rd) and source identification efficiency (rb). A ranking method was developed by combing Gaussian puff model and Source area analysis for improving calculation efficiency. Candidate combinations with highest score were given priority in the selection of next site. Two existing monitors were suggested to relocate to the west and southwest of this park. SE of optimized AQMN increased quickly with monitor number, and then the growth trend started to flatten when the number reached about 60. The highest SE occurred when the number reached 110. Optimal schemes of AQMNs were suggested which can achieve about 98% of the highest SE, while using only about 60 monitors. Finally, the reason why the highest SE is less than 1 and the variation characteristics of rd and rb were discussed. Overall, the proposed method is an effective tool for designing AQMN with optimal SE in industrial parks.

17 December 2018 in Atmosphere
Verified
Journal Article
Open access
PDF file
YLYujie Liu
Yujie Liu
QYQi Yu
Qi Yu
ZHZIHAN HUANG
ZIHAN HUANG
MWMa Weichun
Ma Weichun
Yan ZhangYan Zhang
Yan Zhang
Precise source identification for ambient pollution incidents in industrial parks were often difficult due to limited measurements. Source area analysis method was one of the applicable source identification methods, which could provide potential source areas under these circumstances. However, a source area usually covered several sources and the method was unable to identify the real one. This article introduces a case study on the statistical source identification of methyl mercaptan based on the long-term measurements, in 2014, in an industrial park. A procedure for statistical source area analysis was established, which contains independent pollution episode extraction, source area calculation scenario definition, meteorological data selection, and source area statistical analysis. A total of 414 violation records were detected by five monitors inside the park. Three kinds of calculation scenarios were found and, finally, three key source areas were revealed. The typical scenarios of source area calculations were described in detail. The characteristics of the statistical source areas for all pollution episodes were examined. Finally, the applicability of the method, as well as the source of uncertainties, was discussed. This study shows that more concentrated source areas can be identified through the statistical source area method if several excessive emission sources exist in an industrial park.