Luqmaan Ryklief

Mr. Luqmaan Ryklief


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
LRLuqmaan Ryklief
Luqmaan Ryklief
MBMJ (Thinus) Booysen
MJ (Thinus) Booysen
Charging infrastructure for battery electric bus (BEB) fleets must be sized against the timing of demand, not only its magnitude: an accurate per-trip energy estimate cannot on its own establish whether a depot’s chargers, contracted grid connection, and dispatch schedule can recover the fleet’s energy deficit without breaching demand-based tariff thresholds. This is especially consequential in resource-constrained settings, where notified-maximum-demand penalties and steep time-of-use differentials turn a mistimed charging load into a direct commercial liability rather than an operational inconvenience. Yet pre-investment planning tools typically treat vehicle energy consumption, dispatch scheduling, and charging infrastructure as separate problems, so a validated demand estimate rarely translates into a validated depot load profile. This paper presents an operational digital twin that converts the per-trip arrival state-of-charge predicted by a companion rolling stock twin into a depot-level charging load profile for the Golden Arrow Bus Services (GABS) electric fleet at the Arrowgate depot in Cape Town, South Africa. The twin reconstructs each bus’s daily duty chain from scheduling data to determine its available charging window, then simulates session initiation, power draw, and duration against these windows using charging behaviour parametrised from depot Open Charge Point Protocol (OCPP) records, including the smart charging constraints already enforced at the depot. Each bus’s state of charge is carried from one depot visit to the next, so an undercharged departure reappears as a lower arrival rather than disappearing from the model. The simulated load profile is validated against 968 OCPP session records from two periods with different depot hardware, achieving energy-per-session agreement of 4.3 to 7.3 % and load-shape correlation of 0.95 to 0.99, and is evaluated against the depot’s contracted notified maximum demand of 3 000 kVA. Scenario analysis quantifies how the charging schedule, charger rate, and site pool limit shift the load profile relative to this threshold and to time-of-use cost exposure, showing that scheduling charging into off-peak windows without a site-wide limit can raise peak demand above uncontrolled charging and beyond the contracted threshold (3 167 against 1 832 kW), that a site pool limit controls peak demand and monthly cost together, and that a 30 kW per-charger cap leaves buses unable to complete up to 15 % of their trips. By coupling a validated, condition-aware demand layer to depot dispatch and charging logic, this work supports capital-efficient charging infrastructure decisions for transit operators in the Global South, where undersized infrastructure risks service disruption and oversized infrastructure diverts capital from wider electrification.

31 July 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
LRLuqmaan Ryklief
Luqmaan Ryklief
MBMJ (Thinus) Booysen
MJ (Thinus) Booysen
Sizing charging infrastructure for battery electric bus (BEB) fleets requires an accurate estimate of per-trip energy demand before capital is committed. Accurate sizing is itself a sustainability decision in resource-constrained settings: undersized infrastructure delays the shift away from diesel fleets, while oversized infrastructure diverts capital that could otherwise fund a wider electrification programme. Yet most pre-investment planning still relies on a single fleet-average consumption rate that cannot capture how route, operating conditions, and climate interact. This paper presents a rolling stock digital twin for the Golden Arrow Bus Services (GABS) electric fleet at the Arrowgate depot in Cape Town, South Africa, one of the first large BEB fleets in sub-Saharan Africa. A LightGBM gradient-boosted model is trained on 596 trips drawn from two five-day measurement periods in different seasons (winter and early spring) to predict the per-trip consumption rate (kWh/km) from route-geometry and operating-condition features derived from GPS traces, duty schedules, and public weather data, requiring no vehicle specification beyond a single usable-battery-capacity figure. Under two grouped cross-validation schemes representing known and genuinely unseen routes, the model predicts the per-trip state-of-charge drop, and hence arrival state of charge given a known departure SoC, to within 2.95 and 3.46 percentage points, respectively. SHAP analysis shows that departure time window and ambient temperature, rather than route geometry, dominate the prediction, and the model removes a structured time-of-day bias that the flat rate cannot represent: a roughly 4% underestimate of the morning peak and a 6–7% overestimate of midday and afternoon demand. Independent OCPP charging records corroborate the reconstructed depot demand profile. By replacing an assumed consumption figure with a validated, empirically grounded one, this work supports capital-efficient, lower-risk electrification pathways for transit operators in the Global South, where infrastructure budgets are especially constrained. The twin supplies an empirically grounded, transferable demand layer for depot-level pre-investment planning in resource-constrained operating contexts.

25 October 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
LRLuqmaan Ryklief
Luqmaan Ryklief
MBMJ (Thinus) Booysen
MJ (Thinus) Booysen
Charging infrastructure for battery electric bus (BEB) fleets must be sized against the timing of demand, not only its magnitude: an accurate per-trip energy estimate cannot on its own establish whether a depot’s chargers, contracted grid connection, and dispatch schedule can recover the fleet’s energy deficit without breaching demand-based tariff thresholds. This is especially consequential in resource-constrained settings, where notified-maximum-demand penalties and steep time-of-use differentials turn a mistimed charging load into a direct commercial liability rather than an operational inconvenience. Yet pre-investment planning tools typically treat vehicle energy consumption, dispatch scheduling, and charging infrastructure as separate problems, so a validated demand estimate rarely translates into a validated depot load profile. This paper presents an operational digital twin that converts the per-trip arrival state-of-charge predicted by a companion rolling stock twin into a depot-level charging load profile for the Golden Arrow Bus Services (GABS) electric fleet at the Arrowgate depot in Cape Town, South Africa. The twin reconstructs each bus’s daily duty chain from scheduling data to determine its available charging window, then simulates session initiation, power draw, and duration against these windows using charging behaviour parametrised from depot Open Charge Point Protocol (OCPP) records, including the smart charging constraints already enforced at the depot. Each bus’s state of charge is carried from one depot visit to the next, so an undercharged departure reappears as a lower arrival rather than disappearing from the model. The simulated load profile is validated against 968 OCPP session records from two periods with different depot hardware, achieving energy-per-session agreement of 4.5 to 7.3% and load-shape correlation of 0.95 to 0.99; on a held-out night not used for calibration, with every recorded session as input, the twin reproduces the depot’s measured overnight peak to within 3.3%, and on a July day with no site pool, with nothing calibrated, its mean overnight load to within 0.8%. The simulated load profile is evaluated against the depot’s contracted notified maximum demand of 3000 kVA. Scenario analysis quantifies how the charging schedule, charger rate, and site pool limit shift the load profile relative to this threshold and to time-of-use cost exposure, showing that scheduling charging into off-peak windows without a site-wide limit can raise peak demand above uncontrolled charging and beyond the contracted threshold (3167 against 1832 kW), that a site pool limit controls peak demand and monthly cost together, and that a 30 kW per-charger cap leaves buses unable to complete up to 15% of their trips; grown to 80 buses, the fleet would exceed the depot’s 2025 connector count before its pool limit, which the twin shows as overnight queueing and stranded trips. By coupling a validated, condition-aware demand layer to depot dispatch and charging logic, this work supports capital-efficient charging-infrastructure decisions for transit operators facing demand-based tariffs and constrained grid capacity, as at Arrowgate, where undersized infrastructure risks service disruption and oversized infrastructure diverts capital from wider electrification.