Wen Jianming

Dr. Wen Jianming

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
RWRenming Wang
Renming Wang
YHYili Hu
Yili Hu
DSDezhu Shen
Dezhu Shen
JMJijie Ma
Jijie Ma
JLJianping LI
Jianping LI
WJWen Jianming
Wen Jianming
A novel piezoelectric inchworm actuator driven by one channel DC signal is developed in this paper to simplify excitation signal of the inchworm actuators, and the clamping force of the developed actuator is generated by a DC motor and two permanent magnets. The piezoelectric stack is excited by a sensing signal, which is generated by the separate photoelectric sensor to detect the position of the rotational permanent magnets. A mathematical model is established to predict the motion of the slider. The prototype of the proposed piezoelectric actuator is fabricated, and mechanical output performance is measured. At a voltage of 75 V and frequency of 3.2 Hz, the average output step is 0.241 μm under no-load conditions. The proposed inchworm actuator can be operated by just one channel DC signal and the output displacement is stable, which provides a new idea for the integration design of the piezoelectric actuators in the future.

5 October 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YHYili Hu
Yili Hu
RWRenming Wang
Renming Wang
WJWen Jianming
Wen Jianming
JLJing-Quan Liu
Jing-Quan Liu
A low frequency structure-control-type inertial actuator using miniaturized bimorph piezoelectric vibrators has been proposed to achieve high resolution and high stability with a large linear stroke. These vibrators are fabricated by bonding, thinning and patterning fabrication processes, which are beneficial to realize miniaturization and increase output performance for the system. A theoretical model based on work-energy analysis is established to predict the output displacement characteristics. An experimental system is built to evaluate the performance of the proposed actuator. Experimental results indicate that the stable minimum step displacement is 0.03 μm under a square wave signal of 5 V, 50 Hz and a clamping difference of 3.5 mm. Under the condition of 7 V and 50 Hz, the sample standard deviation is 0.0337 μm in repeatability test. The proposed actuator achieves a stable and accurate linear bidirectional motion with high resolution, high stability, low power consumption and a large working stroke.

7 January 2022 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
GQGuangda Qiao
Guangda Qiao
HLHengyu Li
Hengyu Li
XLXiaohui Lu
Xiaohui Lu
WJWen Jianming
Wen Jianming
TCTinghai Cheng
Tinghai Cheng
Piezoelectric stick-slip actuators (PSSAs) are famous for ultimate working condition adaptability, simple structure, and positioning accuracy. To meet the demand of industrial application, lots of PSSAs designed with flexure hinge mechanisms (FHMs-PSSAs) have been developed to realize the requirements of translational motion, rotational motion, multi-degree-of-freedom (multi-DOF) motion. The output performance of the FHMs-PSSAs has been greatly improved, including load capacity, speed, and accuracy; moreover, some approaches to solve the problem of the backward motion are provided as well. In this work, the working principle of FHMs-PSSAs is introduced, and the excitation signals applicable to FHMs-PSSAs are summarized. Based on the current research and development status, the progress of structure design of FHMs-PSSAs is introduced in accordance with translatory FHMs-PSSAs, rotary FHMs-PSSAs, and multi-DOF FHMs-PSSAs. Additionally, the developed analysis methods and design schemes to improve the performance are introduced, including theoretical analysis methods, consistency scheme of forward and reverse performance, suppression scheme of the backward motion, and improvement scheme of positioning accuracy. The significance of this work can be regarded as a further supplement to the previous review articles on the PSSAs, which will provide a reference and guidance for the future development of FHMs-PSSAs.

7 July 2021 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
JLJianping LI
Jianping LI
LHLidong He
Lidong He
JCJunjie Cai
Junjie Cai
YHYili Hu
Yili Hu
WJWen Jianming
Wen Jianming
NWNen Wan
Nen Wan
In order to decrease the backward motion and improve the motion efficiency, a walking type piezoelectric actuator has been proposed with two ‘legs’ based on the parasitic motion of obliquely assembled PZT stacks. The structure and motion principle of the proposed walking type piezoelectric actuator are described, and its experiment system is set up. Experimental results indicate the proposed piezoelectric actuator could reduce the backward motion effectively. The minimum backward rate α = 2.26% is achieved under the condition of the phase difference θ = 180°, the input voltage U = 120 V and the input frequency f = 1 Hz; the minimum stepping displacement is 0.24 μ m under the condition of U = 5 V, f = 1 Hz and θ = 180°; the maximum speed V max is 2472 μ m s −1 under the condition of U = 120 V and θ = 180°; the maximum vertical load force F Vmax = 6850 g under the condition of U = 120 V, f = 1 Hz and θ = 180°. Furthermore, a dynamic model of the whole walking type piezoelectric actuator is established, and it has been employed to simulate the motion of the proposed walking type piezoelectric actuator. Simulation results present a great agreement of experimental results. This study shows a novel idea for the design of piezoelectric actuators to eliminate the influence of backward motion and improve the output efficiency of the actuator.

22 December 2022 in International Journal of Mechanical Sciences
Verified
Journal Article
Closed access
SLShengrong Lin
Shengrong Lin
JMJijie Ma
Jijie Ma
JLJianping Li
Jianping Li
SLShengjie Li
Shengjie Li
MWMinghao Wang
Minghao Wang
WJWen Jianming
Wen Jianming

25 May 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
QLQitao Lu
Qitao Lu
JMJijie Ma
Jijie Ma
XLXiaohui Lin
Xiaohui Lin
YHYili Hu
Yili Hu
JLJianping LI
Jianping LI
WJWen Jianming
Wen Jianming
The piezoelectric inchworm actuator with high-positioning accuracy and large output force is a potential device to implant microelectrode in the invasive brain–computer interface (BCI). However, the traditional piezoelectric inchworm actuator adopts multichannel electrical control signals from external equipment and rigid-to-rigid friction contact to drive, resulting in complex control and uneven friction. To solve the above problems, in this article, magnetorheological elastomer (MRE) is first proposed as the clamping material of the piezoelectric inchworm actuator. An MRE–capillary–cover sandwich structure is adopted to achieve rigid-to-elastomeric clamping. The driving and clamping actions of the actuator are controlled by two cam mechanisms mounted on the same shaft, and a battery can feed the actuator. A kinetic model is established to analyze and predict the actuator motion. Several crucial clamping parameters are explored, and the performance experiments are conducted to evaluate actuator characteristics. A verification experiment is carried out to prove the feasibility of the microelectrode implantation in the pig brain (0.6% agarose gel). The actuator can reach the maximum velocity of 1250.4 μ m/s and the maximum output force of 420 mN; in the forward/backward motion, the minimum step is 0.5837/0.5912 μ m, and the repeatability is 0.0465/0.0469 μ m; thus, the actuator has great application potential in BCI.