This paper pivots around the influence of thermal parameters on the temperature distribution of a (PV) module. The solar irradiance, ambient temperature, and heat transfer coefficient were examined for four differently manufactured solar modules. A finite element analysis of the solar system was carried out to simulate the prevailing thermal conditions. It was determined through analysis that the heat transfer coefficient had a significant effect on the boundaries of the PV modules. The temperature gradient was relatively high at the boundary, whereas the main body had the least deviation from the mean value of experimental data. The high value of irradiance is favorable for a large PV system, while the heat transfer coefficient should be low for avoiding undulation of the thermal gradient across the plate. The temperature distribution on the surface of the PV modules largely depended on the geometry and the material used for the design purpose.
Solar photovoltaic power generation capacity is rising continuously as a result of various regional, sub-regional renewable energy policies and the impact of technology development, as well as the increasing environmental concerns. Characteristics of photovoltaic modules are provided by manufacturers after they have been tested indoors under standard test conditions. These parameters may vary under exterior conditions. It is thus imperative to establish the quantity of the energy produced by photovoltaic modules under real operation conditions. This study sought to assess the performance of different kinds of photovoltaic module technologies in the city of Gödöllő, Hungary, and ascertain the behaviour of the modules under real outdoor conditions. Modules include amorphous silicon (a-Si), monocrystalline silicon (mc-Si), polycrystalline silicon (pc-Si), transparent monocrystalline silicon module (mc-Si). Measurement of the module characteristics was performed and various meteorological parameters were obtained. Performance parameters such as performance ratio and efficiency are given and analysed. Module temperature was estimated and evaluated in comparison with experimental values. Energy conversion rates of the modules were determined as 9.4%, 4.4%, 10.3%, 8.2% and 10.4% for mc-Si module transparent glass (165 Wp), a-Si module (glass 40Wp), pc-Si module (105 Wp), pc-Si module (60 Wp) and mc-Si (PV-T 180 Wp), respectively. Under the given outdoor conditions, the highest average performance ratio of 85.2% was obtained for the mc-Si module (transparent glass, 165 Wp), exhibiting the best performance, while pc–Si module (60 Wp) showed the least average performance ratio of 71.8%.
1 January 2020 in Journal of Renewable and Sustainable Energy
The temperature of a photovoltaic (PV) system is a critical factor in the photovoltaic conversion process; hence, the practical performance of a PV system significantly depends on its temperature. Several different methods exist for the determination of PV module temperature. In this study, thermography was employed to investigate the thermal behavior of different solar PV modules under outdoor operating conditions. It was observed that the temperature difference across the area of a PV module could reach as high as 12.5–14.8 °C depending on the type of PV module. Hence, the trends for the lowest and highest temperature were not predictable. Glass-to-glass non-frame PV modules exhibited the highest temperature gradients compared to glass-to-Tedlar non-frame modules. The observed temperature gradients demonstrated that measuring the temperature at a single point on the module was not sufficient to accurately represent the temperature over the entirety of the PV module.
16 July 2021 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
A solar dryer has been examined critically by using a constant drying model. The effect of the dynamic losses, intrinsic properties such as thermodynamic, hydrodynamic and psychometric factors, and natural draught during the practical application of the solar drying unit has been investigated. Carson and Moses, and the dynamic and static pressure correlations with the flow field have been used to determine the flow pattern inside the collector, the drying chamber, and the chimney. The energy allocation throughout the drying process has been evaluated by a Sankey diagram. The psychrometric calculation has been made by applying the steady-state-steady flow conditions (SSSF) on the carrier fluid (air). The average drying rate for the given design is 0.31 kg·h−1. The overall drying system efficiency is found to be 19%. The net static-regain (S.R) in the ducting system due to the sudden expansion is 2.22 N·m−2. The plume height for an efficient dilution of outgoing hot air is 1.17 m in addition to the given design. The flat plate collector efficiency for the given design was 26%. The surface temperature of the specimen should not be more than 321 K during a constant rate period. The pressure loss due to sudden contraction was found to be 73.48% lower than that of sudden expansion. Drying consumed 0.3% of the global irradiance for the drying purpose, whereas 57% of net received energy was absorbed by carrier fluid. The study encompassed the variability in the input that influence the performance of the solar collector since quantitative workout might not be effective unless the rheology is considered.