Tao Qian

Dr. Tao Qian


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Radiology
Verified
Journal Article
Closed access
TATao Ai
Tao Ai
ZYZhenlu Yang
Zhenlu Yang
HHHongyan Hou
Hongyan Hou
CZChenao Zhan
Chenao Zhan
CCChong Chen
Chong Chen
LXLiming Xia
Liming Xia
Background Chest CT is used for diagnosis of 2019 novel coronavirus disease (COVID-19), as an important complement to the reverse-transcription polymerase chain reaction (RT-PCR) tests. Purpose To ...

1 April 2020 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
LHLu Huang
Lu Huang
RHRui Han
Rui Han
TATao Ai
Tao Ai
PYPengxin Yu
Pengxin Yu
HKHan Kang
Han Kang
LXLiming Xia
Liming Xia
Purpose To quantitatively evaluate lung burden changes in patients with COVID-19 using serial CT scan by an automated deep learning method. Materials and Methods Patients with COVID-19 who underwen...

1 January 2019 in Radiology
Verified
Journal Article
Open access
TQTao Qian
Tao Qian
WYWenjun Yan
Wenjun Yan
YWYuanyuan Wang
Yuanyuan Wang
EPElisabeth H. M. Paiman
Elisabeth H. M. Paiman
DSDenis P. Shamonin
Denis P. Shamonin
RGRob J van der Geest
Rob J van der Geest
A deep learning–based algorithm can achieve fully automated, accurate left ventricle segmentation from short-axis cine MR images when tested against a multivendor, multicenter data set. PurposeTo develop a deep learning–based method for fully automated quantification of left ventricular (LV) function from short-axis cine MR images and to evaluate its performance in a multivendor and multicenter setting.Materials and MethodsThis retrospective study included cine MRI data sets obtained from three major MRI vendors in four medical centers from 2008 to 2016. Three convolutional neural networks (CNNs) with the U-NET architecture were trained on data sets of increasing variability: (a) a single-vendor, single-center, homogeneous cohort of 100 patients (CNN1); (b) a single-vendor, multicenter, heterogeneous cohort of 200 patients (CNN2); and (c) a multivendor, multicenter, heterogeneous cohort of 400 patients (CNN3). All CNNs were tested on an independent multivendor, multicenter data set of 196 patients. CNN performance was evaluated with respect to the manual annotations from three experienced observers in terms of (a) LV detection accuracy, (b) LV segmentation accuracy, and (c) LV functional...

10 October 2019
Verified
Book Chapter
Closed access
PDF file
WYWenjun Yan
Wenjun Yan
YWYuanyuan Wang
Yuanyuan Wang
SGShengjia Gu
Shengjia Gu
LHLu Huang
Lu Huang
FYFuhua Yan
Fuhua Yan
TQTao Qian
Tao Qian

1 July 2020 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
WYWenjun Yan
Wenjun Yan
LHLu Huang
Lu Huang
LXLiming Xia
Liming Xia
SGShengjia Gu
Shengjia Gu
FYFuhua Yan
Fuhua Yan
TQTao Qian
Tao Qian
A deep learning segmentation tool developed by using MRI data from one MRI scanner may not generalize well to MRI data from another MRI manufacturer’s scanner; the authors propose an MRI manufactur... PurposeTo quantitatively evaluate the generalizability of a deep learning segmentation tool to MRI data from scanners of different MRI manufacturers and to improve the cross-manufacturer performanc...

20 May 2010 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
TQTao Qian
Tao Qian
JMJulien Milles
Julien Milles
KZKatja Zeppenfeld
Katja Zeppenfeld
HLHildo J. Lamb
Hildo J. Lamb
JBJeroen J. Bax
Jeroen J. Bax
RGRob J van der Geest
Rob J van der Geest
Accurate assessment of the size and distribution of a myocardial infarction (MI) from late gadolinium enhancement (LGE) MRI is of significant prognostic value for postinfarction patients. In this paper, an automatic MI identification method combining both intensity and spatial information is presented in a clear framework of (i) initialization, (ii) false acceptance removal, and (iii) false rejection removal. The method was validated on LGE MR images of 20 chronic postinfarction patients, using manually traced MI contours from two independent observers as reference. Good agreement was observed between automatic and manual MI identification. Validation results showed that the average Dice indices, which describe the percentage of overlap between two regions, were 0.83 ± 0.07 and 0.79 ± 0.08 between the automatic identification and the manual tracing from observer 1 and observer 2, and the errors in estimated infarct percentage were 0.0 ± 1.9% and 3.8 ± 4.7% compared with observer 1 and observer 2. The difference between the automatic method and manual tracing is in the order of interobserver variation. In conclusion, the developed automatic method is accurate and robust in MI delineation, providing an objective tool for quantitative assessment of MI in LGE MR imaging. Magn Reson Med, 2010.