M Khan

Dr. M Khan


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2015 in Trials
Verified
Journal Article
Open access
PDF file
AHAstrid A. Hendriks
Astrid A. Hendriks
MKM Khan
M Khan
LGLaszlo Geller
Laszlo Geller
AKAttila Kardos
Attila Kardos
LVLennart J. de Vries
Lennart J. de Vries
TSTamas Szili-Torok
Tamas Szili-Torok
The role of epicardial substrate ablation of ventricular tachycardia (VT) as a first-line approach in patients with ischemic heart disease is not clearly defined. Epicardial ablation as a first-line option is standard for patients with nonischemic dilated cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy. Several nonrandomized studies, including studies on patients with ischemic heart disease, have shown that epicardial VT ablation improves outcome but this approach was often used after a failed endocardial approach. The aim of this study is to determine whether a combined endo-epicardial scar homogenization as a first-line approach will improve the outcome of VT ablation. The EPILOGUE study is a multicenter, two-armed, nonblinded, randomized controlled trial. Patients with ischemic heart disease who are referred for VT ablation will be randomly assigned to combined endo-epicardial scar homogenization or endocardial scar homogenization only (control group). The primary outcome is recurrence of sustained VT during a 2-year follow-up. Secondary outcomes include procedural success and safety. This study is the first randomized trial that evaluates the role of a combined endo-epicardial scar homogenization versus endocardial scar homogenization for the treatment of ischemic scar-related VT. NL4816807814v02

15 September 2021 in JACC: Case Reports
Verified
Journal Article
Open access
DRDafne van Rijn
Dafne van Rijn
AHAstrid A. Hendriks
Astrid A. Hendriks
ANAnne-Marie M.E. Noten
Anne-Marie M.E. Noten
LHLoek van Heerebeek
Loek van Heerebeek
MKM Khan
M Khan
Pulmonary vein isolation (PVI) using cryoballoon causes acute tissue edema of the osteal region of the pulmonary veins and the left atrium. In two cases combining PVI with an implantation of a left atrial appendage closure device led to malsizing of the device, device shouldering, and a paraprosthetic residual flow. (Level of Difficulty: Advanced.)

Verified
Journal Article
Open access
PDF file
BMBakhtawar Khan Mahmoodi
Bakhtawar Khan Mahmoodi
JBJippe Balt
Jippe Balt
MKM Khan
M Khan
MWMaurits C Wijffels
Maurits C Wijffels
GRGijsbert S. de Ruiter
Gijsbert S. de Ruiter
Sing-Chien YapSing-Chien Yap
Sing-Chien Yap
Background: Catheter ablation of regular atrial tachyarrhythmias (ATs) relies on high-density electroanatomical mapping and can be technically challenging. We compared the mapping efficiency of the Octaray and Pentaray catheters in patients undergoing AT mapping. Methods: Patients with either left or right AT underwent three-dimensional Coherent mapping using both the Octaray and Pentaray catheters in a randomized cross-over design. The primary endpoint was the total number of electrograms acquired per map at a predefined filling threshold of 5 mm. Results: A total of 46 patients with left or right AT were enrolled across three ablation centers. Successful mapping with both catheters was achieved in 39 patients (20 left ATs and 19 right ATs). The median number of electrograms acquired per map (7437 vs. 4679; p < 0.001) and median electrogram density (50.2 vs. 29.8 electrograms/cm2; p < 0.001) was significantly higher with Octaray than with Pentaray. Furthermore, median mapping times were significantly shorter with Octaray (5.4 vs. 8.1 min; p < 0.001), resulting in an approximately 2.5-fold higher acquisition rate (1489 vs. 602 electrograms/minute; p < 0.001). In addition, Octaray demonstrated a significantly lower proportion of internal points compared with Pentaray, particularly in low-voltage regions (bipolar voltage < 0.5 mV; 22% vs. 44%; p = 0.01). Conclusions: Compared with Pentaray, use of the Octaray catheter facilitated faster high-density electroanatomical mapping of complex ATs, thereby improving mapping efficiency.