Background: In this study, stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype was compared with a conventional energy-integrating detector CT (EIDCT) system. Methods: An ex vivo phantom was created, consisting of a 2% agar-water mixture, in which human-resected and stented arteries were individually embedded. Using similar technique parameters, helical scan data was acquired using a novel prototype Si-PCCT and a conventional EIDCT system at a volumetric CT dose index (CTDIvol) of 9 mGy. Reconstructions were made at 502 and 1502 mm2 field-of-views (FOVs) using a bone kernel and adaptive statistical iterative reconstruction with 0% blending. Using a 5-point Likert scale, reader evaluations were performed on stent appearance, blooming and inter-stent visibility. Quantitative image analysis was performed on stent diameter accuracy, blooming and inter-stent distinction. Qualitative and quantitative differences between Si-PCCT and EIDCT systems were tested with a Wilcoxon signed-rank test and a paired samples t-test, respectively. Inter- and intra-reader agreement was assessed using the intraclass correlation coefficient (ICC). Results: Qualitatively, Si-PCCT images were rated higher than EIDCT images at 150-mm FOV, based on stent appearance (p = 0.026) and blooming (p = 0.015), with a moderate inter- (ICC = 0.50) and intra-reader (ICC = 0.60) agreement. Quantitatively, Si-PCCT yielded more accurate diameter measurements (p = 0.001), reduced blooming (p < 0.001) and improved inter-stent distinction (p < 0.001). Similar trends were observed for the images reconstructed at 50-mm FOV. Conclusions: When compared to EIDCT, the improved spatial resolution of Si-PCCT yields enhanced stent appearance, more accurate diameter measurements, reduced blooming and improved inter-stent distinction. Key points: • This study evaluated stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype. • Compared to standard CT, Si-PCCT resulted in more accurate stent diameter measurements. • Si-PCCT also reduced blooming artefacts and improved inter-stent visibility.
Objective. To investigate dynamic shuttle-mode xenon (Xe)-enhanced dual-energy CT (Xe-DECT) imaging for a regional assessment of ventilation in in vivo rabbit lungs. Approach. Four mechanically ventilated rabbits were scanned during the washout of a 70% xenon in 30% oxygen gas mixture using dynamic shuttle-mode DECT at baseline and during methacholine (MCh)-induced bronchoconstriction (post-MCh). Material decomposition was applied to generate xenon and tissue density images (mg ml −1 ). A tissue-based correction was used to isolate the xenon concentration ( CXe ) in the gas phase of the xenon density images. The resultant CXe images were used to investigate regional ventilation defects (VDs) by comparing the VD fraction (VDF, expressed as percentage) between baseline and post-MCh conditions. Additionally, regional ventilation efficiency within the VDs and surrounding (non-VD) areas was quantified as specific ventilation ( in min −1 ). Ventilation was also qualitatively assessed by evaluating ventilation distributions during washout. Main results. MCh-induced bronchoconstriction resulted in an increase in VDF. The average VDF at baseline was 13.8 ± 8.5%, compared to an average post-MCh VDF of 29.6 ± 7.7%, p = 0.026. The VDs at baseline did not reveal a reduced ventilation efficiency ( 8.4 ± 2.7 min −1 ), compared to non-VD areas ( 7.0 ± 3.1 min −1 ), p = 0.306. In contrast, MCh-induced VDs were found to have a reduced ventilation efficiency ( 4.9 ± 2.3 min −1 ), compared to non-VD areas ( : 6.4 ± 2.3 min −1 ), p = 0.004 . Significance. Dynamic shuttle-mode Xe-DECT during washout enabled regional evaluation of ventilation in healthy and pathological in vivo rabbit lungs. As traditional lung function tests offer only global assessments of respiratory impairment, there is a growing interest in pulmonary functional imaging to enable quantitative evaluation of regional lung function.
To compare plaque-stent interface using an experimental Silicon-based photon-counting CT (Si-PCCT) with a conventional energy-integrating detector CT (EIDCT). A human-resected and stented artery was embedded centrally into an agar-water phantom and scanned in a Si-PCCT and an EIDCT using a similar scan technique targeting a CT volumetric dose index (CTDIvol) of 9 mGy. Images were reconstructed using equivalent settings at 150 mm and 50 mm field-of-view (150FOV, 50FOV). Plaque-stent distinction, stent diameter measurement accuracy and blooming were quantitatively and qualitatively assessed using a 5-point Likert scale. Result comparisons between systems and FOVs were evaluated with a t-test and a Wilcoxon signed-rank test with inter-reader agreement assessed using intra-class correlation (ICC). Additionally, EIDCT and Si-PCCT images from a single clinical carotid angiography case were compared. Si-PCCT enabled improved plaque-stent contrast and reduced blooming (p < 0.001) at both FOVs, whereas diameter measurement accuracy was only improved at 50FOV (p = 0.003), compared to EIDCT. 150FOV Si-PCCT images were preferred over EIDCT images forstent appearance (p = 0.001), plaque appearance (p < 0.001), stent-plaque distinction (p = 0.002) and blooming (p = 0.001). 50FOV showed similar trends. 50FOV EIDCT images enabled improved plaque-stent contrast (p = 0.046), reduced blooming (p < 0.001), and improved stent appearance (p = 0.025). For Si-PCCT, no improvements were observed at 50FOV. Quantitative and qualitative ICC was 0.93 and 0.96, respectivelyThe experimental findings are reflected in the evaluation of the patient case. This study demonstrates the potential of Si-PCCT to improve image contrast and spatial resolution, enabling improved assessment of plaque and stent in an experimental phantom and a clinical patient case.
Background/Objectives: Pulmonary diseases exhibit spatially heterogeneous functional and structural abnormalities that are inadequately represented by conventional lung function testing. This pilot study investigates dynamic xenon-enhanced dual-energy CT (Xe-DECT) for a multiparametric assessment of lung ventilation and tissue. Methods: Four mechanically ventilated rabbits were scanned during washout of 70% xenon in oxygen using multibreath imaging with a clinical DECT both before (baseline) and after methacholine administration (post-MCh). Tracheal Xe concentration (CXe) and flow were monitored using mass spectrometry and pneumotachometry to estimate specific ventilation () and end-expiratory lung volume (EELVms). DECT-derived xenon concentration and tissue density images (mg/mL) were obtained by material decomposition, yielding and EELVDECT, respectively. Agreement with mass spectrometry and differences between baseline and post-MCh were assessed. Results: The baseline and EELVDECT agreed with the mass spectrometry, with mean differences of 0.6 min−1 [−0.2 min−1, 1.4 min−1] and 0.6 mL [−6.7 mL, 7.9 mL], respectively. Following MCh administration, the mean differences increased to −2.9 min−1 [−4.1 min−1, −1.6 min−1] for and 1.3 mL [−15.3 mL, 12.8 mL] for EELV. Post-MCh, decreased from 8.6 ± 1.6 min−1 to 3.7 ± 0.9 min−1 (p = 0.034) and EELVDECT from 29.3 ± 1.0 mL to 27.0 ± 1.3 mL (p = 0.036), whereas (p = 0.308) and EELVms (p = 0.653) showed no substantial changes. Regional analysis revealed that in well-ventilated regions matched tracheal . Conclusions: Dynamic Xe-DECT imaging enabled spatial and quantitative assessments of specific ventilation and tissue densities in an in vivo rabbit model. This technique allowed detection of focal alterations that remained undetected by tracheal measurements.