JAVIER ORLANDO ROA ROMERO

Mr. JAVIER ORLANDO ROA ROMERO

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Yash BhambhaniYash Bhambhani
Yash Bhambhani
Mario OrtizMario Ortiz
Mario Ortiz
Eduardo IáñezEduardo Iáñez
Eduardo Iáñez
JMJazmin A. Diaz Martinez
Jazmin A. Diaz Martinez
JRJAVIER ORLANDO ROA ROMERO
JAVIER ORLANDO ROA ROMERO
Jose M. AzorinJose M. Azorin
Jose M. Azorin
EEG-based motor imagery (MI) decoding is commonly evaluated in open loop, but strong offline performance does not necessarily translate into stable real-time control once decoder outputs drive a physical device. This issue is especially relevant for lower-limb exoskeletons, where initiating movement, sustaining movement, stopping movement, and maintaining rest can impose different controller-level demands. This study presents a proof-of-concept controller-level validation of an EEG-driven ankle exoskeleton framework, using a staged design that links open-loop decoder development to real-time closed-loop controller testing. Open-loop EEG data were collected from nine able-bodied participants during static and dynamic ankle MI using an eight-channel g.tec Unicorn Hybrid Black system, with matched PA-SEMI outputs available for eight participants in the primary open-loop comparison. We used a hybrid feature representation combining spectral, spatial covariance, and temporal complexity descriptors to compare a supervised Passive–Aggressive (PA) classifier with a Semi-supervised latent learning network (SEMI). Performance was assessed using epoch-level and persistence-based event metrics intended to reflect controller triggering. Under the evaluated model-specific protocols, SEMI produced higher open-loop accuracy and lower false-trigger rates than PA. The reported SEMI analysis was transductive: feature windows from the target-participant evaluation runs were available without labels during consistency training, and their labels were withheld until final evaluation. However, we selected PA for the primary matched closed-loop validation because it could be retrained, checked, and deployed within the same-day workflow. Since SEMI was not evaluated in a balanced matched closed-loop comparison, this study does not determine whether PA or SEMI provides superior real-time controller performance. Deployment-oriented PA updates were audited using limited same-day calibration data and evaluated in matched PA-based closed-loop trials with three participants, based on online controller logs. The closed-loop experiments were conducted on RehAnkle, a pre-commercial robotic ankle rehabilitation device operated here as a single-active-DoF ankle platform for dorsiflexion-oriented EEG control. In closed-loop trials, start and stop commands were generally reliable, whereas sustained movement and sustained rest were less stable. These proof-of-concept results indicate that command generation and state maintenance should be evaluated as separate controller-level problems, and that open-loop accuracy alone is insufficient to characterize real-time exoskeleton control.