The absolute positioning accuracy of a robot is an important specification that determines its performance, but it is affected by several error sources. Typical calibration methods only consider kinematic errors and neglect complex non-kinematic errors, thus limiting the absolute positioning accuracy. To further improve the absolute positioning accuracy, we propose an artificial neural network optimized by the differential evolution algorithm. Specifically, the structure and parameters of the network are iteratively updated by differential evolution to improve both accuracy and efficiency. Then, the absolute positioning deviation caused by kinematic and non-kinematic errors is compensated using the trained network. To verify the performance of the proposed network, the simulations and experiments are conducted using a six-degree-of-freedom robot and a laser tracker. The robot average positioning accuracy improved from 0.8497 mm before calibration to 0.0490 mm. The results demonstrate the substantial improvement in the absolute positioning accuracy achieved by the proposed network on an industrial robot.
The measurement accuracy of the precision instruments that contain rotation joints is influenced significantly by the rotary encoders that are installed in the rotation joints. Apart from the imperfect manufacturing and installation of the rotary encoder, the variations of ambient temperature could cause the angle measurement error of the rotary encoder. According to the characteristics of the periodicity of the angle measurement at the stationary temperature and the complexity of the effects of ambient temperature changes, the method based on the Fourier expansion-back propagation (BP) neural network optimized by genetic algorithm (FE-GABPNN) is proposed to improve the angle measurement accuracy of the rotary encoder. The proposed method, which innovatively integrates the characteristics of Fourier expansion, the BP neural network and genetic algorithm, has good fitting performance. The rotary encoder that is installed in the rotation joint of the articulated coordinate measuring machine (ACMM) is calibrated by using an autocollimator and a regular optical polygon at ambient temperature ranging from 10 to 40 °C. The contrastive analysis is carried out. The experimental results show that the angle measurement errors decrease remarkably, from 110.2″ to 2.7″ after compensation. The mean root mean square error (RMSE) of the residual errors is 0.85″.
This paper presents a novel impact rotary motor based on a piezoelectric tube actuator with helical interdigitated electrodes which has a compact structure and high resolution. The assembled prototype motor has a maximum diameter of 15 mm and a length of 65 mm and works under a saw-shaped driving voltage. The LuGre friction model is adopted to analyze the rotary motion process of the motor in the dynamic simulations. From the experimental tests, the first torsional resonant frequency of the piezoelectric tube is 59.289 kHz with a free boundary condition. A series of experiments about the stepping characteristics of different driving voltages, duty cycles, and working frequencies are carried out by a laser Doppler vibrometer based on a fabricated prototype motor. The experimental results show that the prototype rotary motor can produce a maximum torsional angle of about 0.03° using a driving voltage of 480 Vp-p (peak-to-peak driving voltage) with a duty ratio of 0% under a small friction force of about 0.1 N. The motor can produce a maximum average angle of about 2.55 rad/s and a stall torque of 0.4 mN∙m at 8 kHz using a driving voltage of 640 Vp-p with a duty ratio of 0% under a large friction force of about 3.6 N. The prototype can be driven in forward and backward motion and is working in stick-slip mode at low frequencies and slip-slip mode at high frequencies.
28 September 2015 in Journal of Radioanalytical and Nuclear Chemistry
A novel impact two-degree-of-freedom (2-DOF) motor based on the decomposed screw-type motion of a piezoelectric actuator (PA) has been proposed. The fabricated prototype motor has a maximum diameter of 15 mm and a length of 100 mm which can produce a maximum torsional angle of about 1000 μrad and a maximum longitudinal displacement of about 1.03 μm under a saw-shaped driving voltage with 720 Vp-p (peak-to-peak driving voltage). When the axial prepressure generated by the spring is about 1N and the radial prepressure generated by the snap ring is about 14 N, the fabricated motor realizes rotary motion with the driving frequency from 200 Hz to 4 kHz. When the axial prepressure generated by the spring is about 11.7 N and the radial prepressure generated by the snap ring is about 21.1 N, the fabricated motor realizes linear motion with the driving frequency from 2 kHz to 11 kHz. In the experiments, the prototype motor can achieve 9.9 × 105 μrad/s rotary velocity at 2 kHz and it can achieve 2.4 mm/s linear velocity at 11 kHz under the driving voltage of 720 Vp-p.