Domenico Romeo

Dr. Domenico Romeo

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
FRfrancesca romano
francesca romano
DRDomenico Romeo
Domenico Romeo
SMSara Ciullini Mannurita
Sara Ciullini Mannurita
EREdda Russo
Edda Russo
EMEva Milletti
Eva Milletti
ABAlessandro Bonari
Alessandro Bonari
Background: Modern hematology analyzers integrate multiparametric technologies and adaptive flagging algorithms to support rapid detection of abnormal leukocyte populations. The Sysmex XN-9100 employs the White Blood Cell Differential (WDF) channel for first-line screening and the White Precursor Cell (WPC) channel as a reflex test for improved detection of blasts and abnormal lymphocytes. Although widely implemented, the real-world diagnostic performance and workflow implications of this integrated strategy remain incompletely characterized. Objectives: To evaluate, in a large real-world cohort, the performance of the Sysmex XN-9100 WDF–WPC workflow, focusing on its diagnostic accuracy, its capability to identify pathological cases within the WDF-negative population, and its potential implications for blood smear review workload optimization. Methods: A retrospective analysis was performed on 4531 consecutive routine blood samples reviewed between February and June 2025. All samples were analyzed using the Sysmex XN-9100. WDF-positive cases (“Blasts/Abnormal lymphocytes?”) underwent reflex WPC testing (“Blasts?” and “Abnormal lymphocytes?”). Peripheral blood smear morphology, based on the evaluation of 200 leukocytes using the DI-60 digital imaging system, constituted the reference standard. Diagnostic performance metrics, including sensitivity, specificity, predictive values, likelihood ratios, accuracy, and ROC analysis, were calculated for WDF and WPC channels using both individual and aggregated flag evaluations. Results: The WDF-B/AL (White Blood Cell Differential Channel-“Blasts/Abnormal lymphocytes?”) flag demonstrated high sensitivity (88.24%) and negative predictive value (92.73%), supporting its role as an effective first-line screening tool, although specificity was limited (48.87%; AUC = 0.75). Unlike most previous studies, our workflow allowed evaluation of pathological cases occurring within the WDF-negative population, providing a realistic estimate of the false-negative burden. Disaggregated WPC analysis revealed complementary diagnostic profiles: WPC-B (White Precursor Cell Channel-“Blasts?”) showed higher specificity (77.71%) and overall discriminative performance (AUC = 0.81), whereas WPC-AL (White Precursor Cell Channel-“Abnormal lymphocytes?”) achieved higher sensitivity (92.18%) and negative predictive value (95.99%). Aggregated evaluation of WPC flags (logical OR) maximized sensitivity (92.68%) and reduced false-negative cases, supporting the role of the WPC channel as a second-level diagnostic safety net. Furthermore, within the integrated laboratory workflow, WPC-negative results may support the optimization of manual smear-review allocation when interpreted together with predefined institutional smear-review criteria, while maintaining diagnostic safety. Conclusions: The Sysmex XN-9100 WDF–WPC workflow constitutes a multilayered high-sensitivity screening strategy that prioritizes abnormality detection while optimizing laboratory efficiency. The complementary behavior of WPC-B and WPC-AL enhances overall workflow safety, whereas evaluation of WDF-negative pathological cases provides a more realistic assessment of screening performance than conventional reflex-based studies. Beyond analytical accuracy, the workflow may contribute to balancing diagnostic reliability, patient safety, and resource utilization in high-volume laboratory practice.

19 August 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
SMSara Ciullini Mannurita
Sara Ciullini Mannurita
DRDomenico Romeo
Domenico Romeo
ABAlessandro Bonari
Alessandro Bonari
EREdda Russo
Edda Russo
PNPamela Nardiello
Pamela Nardiello
FRfrancesca romano
francesca romano
Background/Objectives: Modern automated hematology analyzers combine quantitative cell counting with proprietary algorithms for automated morphological interpretation. While analytical validation traditionally focuses on measurement agreement, less attention has been paid to the evaluation of algorithm-assisted morphological interpretation. This study compared the analytical performance and automated morphological flagging of the Sysmex XN-9100 and Mindray BC-7800/BC-7900 platforms under routine laboratory conditions. Methods: A total of 183 peripheral blood samples collected between October 2025 and February 2026 were analyzed in parallel using both platforms. The study population included healthy individuals and patients with hematological and non-hematological disorders. Analytical agreement for complete blood count (CBC) and leukocyte differential parameters was assessed using Passing–Bablok regression and Bland–Altman analyses. Automated morphological flagging was evaluated in 157 samples using expert optical microscopy as the reference standard. McNemar’s test, Cohen’s kappa coefficient, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. Results: Excellent agreement was observed for the principal CBC parameters, including white blood cell count, red blood cell count, hemoglobin, hematocrit, mean corpuscular volume, and platelet count (correlation coefficients: 0.981–1.000), with minimal proportional bias. Greater variability was found for monocytes, eosinophils, and basophils, particularly at low cell concentrations. Although analytical performance was highly comparable, the two platforms showed different morphological flagging profiles. Both analyzers achieved high negative predictive values (>90%), while differences in sensitivity and specificity across individual flag categories reflected distinct algorithm-assisted classification strategies. Agreement with expert microscopy ranged from fair to moderate for most pathological flags. Conclusions: The Mindray BC-7800/BC-7900 and Sysmex XN-9100 demonstrated excellent analytical agreement for routine CBC testing. However, comparable analytical performance did not necessarily correspond to identical automated morphological interpretation. These results indicate that evaluation of modern hematology analyzers should include both analytical performance and agreement between automated flags and expert microscopy.