MARCO ANIBAL LEON SEGOVIA

Prof. MARCO ANIBAL LEON SEGOVIA

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2021 in Universidad Ciencia y Tecnología
Verified
Journal Article
Open access
PDF file
SRSecundino Marrero Ramírez
Secundino Marrero Ramírez
IPIliana González Palau
Iliana González Palau
MSMARCO ANIBAL LEON SEGOVIA
MARCO ANIBAL LEON SEGOVIA
SESuarez Vinueza Rommel Eusebio
Suarez Vinueza Rommel Eusebio
La investigación se realizó en un el invernadero experimental inacral para el control de humedad y consumo de agua, con el uso de sensores de temperatura, humedad, nivel y un PLC a través de un sistema Scada. Se pudo establecer el control manual y automático de la humedad en los rangos requeridos y con una electroválvula se controla el llenado del tanque con los niveles mínimo y máximo programados. En la interfaz gráfica (HMI) se controla y monitorea de formaremota el gasto de agua y el comportamiento de la humedad. También es posible conocer el consumo de agua diario, semanal y mensual, así como el nivel y volumen del agua existente en el tanque. El sistema facilitó el trabajo en el invernadero, mejoró la calidad del cultivo y permitió el seguimiento del gasto de agua por plantas, la dosificación correcta y el uso racional de este recurso. Palabras Clave: Control, Sensores, Scada, HMI. Referencias

31 October 2026 in Innova Science Journal
Verified
Journal Article
Open access
PDF file
CCCristhian Jonathan Chiliquinga-Flores
Cristhian Jonathan Chiliquinga-Flores
CCCarlos Ivan Quinatoa Caiza
Carlos Ivan Quinatoa Caiza
MSMARCO ANIBAL LEON SEGOVIA
MARCO ANIBAL LEON SEGOVIA
Integrating renewable energy sources into power grids presents challenges regarding energy variability, dynamic stability, and supply continuity during grid outages; this research addresses the coordination of photovoltaic generation, energy storage, and backup power generation to ensure the resilient operation of critical loads. The study aims to develop and analyze a hybrid microgrid through dynamic simulation using DIgSILENT PowerFactory 2024, integrating a 2.5 MWp photovoltaic plant, a 6 MWh battery energy storage system (BESS), and a 3.2 MW diesel backup generator. The methodology involves dynamic modeling of electrical components, the implementation of an energy management system via a Python API, and a hierarchical load-sharing strategy. The photovoltaic system incorporates an MPPT controller with temperature compensation, while the BESS is evaluated using bidirectional control, state-of-charge calculations, and grid-following and grid-forming strategies. Validation was conducted using dynamic scenarios involving irradiance variations and transitions to islanded operation; results demonstrated that the microgrid maintained a continuous power supply to a 2.47 MW critical load during two islanded operation episodes, achieving surpluses of 1.08 MW and 0.58 MW, respectively. The battery energy storage system provided dynamic support with charging power of up to -0.75 MW and discharging power of 0.80 MW, maintaining frequency stability around 60 Hz.

14 October 2026 in Electronics
Verified
Journal Article
Open access
PDF file
CCCarlos Ivan Quinatoa Caiza
Carlos Ivan Quinatoa Caiza
WCWilliam La Cruz
William La Cruz
ALAlex Ivan Paguay Llamuca
Alex Ivan Paguay Llamuca
MSMARCO ANIBAL LEON SEGOVIA
MARCO ANIBAL LEON SEGOVIA
Cristian Laverde-AlbarracínCristian Laverde-Albarracín
Cristian Laverde-Albarracín
Diego Carmona FernándezDiego Carmona Fernández
Diego Carmona Fernández
Distribution networks are operating under increasingly variable conditions as renewable generation and electric vehicles become more widespread. Maintaining reliable and secure operation in this setting requires timely information about the electrical state of the network, yet DSSE remains difficult to implement when measurement coverage is sparse, communication infrastructure is limited, and feeder configurations are complex enough to compromise observability. This review examines how current DSSE methods deal with these conditions, including high R/X ratios, three-phase unbalance, and limited instrumentation. More than one hundred studies are considered, spanning optimization-based estimators and related mean-squared-error formulations, Kalman-filter-based dynamic approaches, artificial intelligence techniques, and centralized and distributed estimation schemes. Their reported advantages, limitations, and application areas are assessed in the context of practical deployment requirements. The review also considers directions that combine physical network models with neural networks, improve pseudo-measurement generation, account for dynamic and stochastic behavior, and distribute the estimation process through approaches such as Bayesian consensus filtering and the alternating direction method of multipliers. Comparative tables summarize the main characteristics of these methods, while the discussion gives particular attention to real-time implementation, cybersecurity, and operational constraints encountered in modern distribution networks.