Arkadiusz Sitek

Dr. Arkadiusz Sitek

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2011 in Circulation
Verified
Journal Article
Closed access
PDF file
VMVenkatesh L. Murthy
Venkatesh L. Murthy
MNMasanao Naya
Masanao Naya
CFCourtney R. Foster
Courtney R. Foster
JHJon Hainer
Jon Hainer
MGMariya Gaber
Mariya Gaber
MCMarcelo F. Di Carli
Marcelo F. Di Carli
Background—: Impaired vasodilator function is an early manifestation of coronary artery disease and may precede angiographic stenosis. It is unknown whether noninvasive assessment of coronary vasodilator function in patients with suspected or known coronary artery disease carries incremental prognostic significance. Methods and Results—: A total of 2783 consecutive patients referred for rest/stress positron emission tomography were followed up for a median of 1.4 years (interquartile range, 0.7–3.2 years). The extent and severity of perfusion abnormalities were quantified by visual evaluation of myocardial perfusion images. Rest and stress myocardial blood flows were calculated with factor analysis and a 2-compartment kinetic model and were used to compute coronary flow reserve (coronary flow reserve equals stress divided by rest myocardial blood flow). The primary end point was cardiac death. Overall 3-year cardiac mortality was 8.0%. The lowest tertile of coronary flow reserve (<1.5) was associated with a 5.6-fold increase in the risk of cardiac death (95% confidence interval, 2.5–12.4; P <0.0001) compared with the highest tertile. Incorporation of coronary flow reserve into cardiac death risk assessment models resulted in an increase in the c index from 0.82 (95% confidence interval, 0.78–0.86) to 0.84 (95% confidence interval, 0.80–0.87; P =0.02) and in a net reclassification improvement of 0.098 (95% confidence interval, 0.025–0.180). Addition of coronary flow reserve resulted in correct reclassification of 34.8% of intermediate-risk patients (net reclassification improvement=0.487; 95% confidence interval, 0.262–0.731). Corresponding improvements in risk assessment for mortality from any cause were also demonstrated. Conclusion—: Noninvasive quantitative assessment of coronary vasodilator function with positron emission tomography is a powerful, independent predictor of cardiac mortality in patients with known or suspected coronary artery disease and provides meaningful incremental risk stratification over clinical and gated myocardial perfusion imaging variables.

1 May 2007 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MCMarcelo F. Di Carli
Marcelo F. Di Carli
SDSharmila Dorbala
Sharmila Dorbala
JMJolene Meserve
Jolene Meserve
GFGeorges El Fakhri
Georges El Fakhri
ASArkadiusz Sitek
Arkadiusz Sitek
SMStephen C. Moore
Stephen C. Moore
The field of nuclear cardiology is witnessing growing interest in the use of cardiac PET for the evaluation of patients with coronary artery disease (CAD). The available evidence suggests that myocardial perfusion PET provides an accurate means for diagnosing obstructive CAD, which appears superior to SPECT especially in the obese and in those undergoing pharmacologic stress. The ability to record changes in left ventricular function from rest to peak stress and to quantify myocardial perfusion (in mL/min/g of tissue) provides an added advantage over SPECT for evaluating multivessel CAD. There is growing and consistent evidence that gated myocardial perfusion PET also provides clinically useful risk stratification. Although the introduction of hybrid PET/CT technology offers the exciting possibility of assessing the extent of anatomic CAD (CT coronary angiography) and its functional consequences (ischemic burden) in the same setting, there are technical challenges in the implementation of CT-based transmission imaging for attenuation correction. Nonetheless, this integrated platform for assessing anatomy and biology offers a great potential for translating advances in molecularly targeted imaging into humans.

12 June 2009 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
GFGeorges El Fakhri
Georges El Fakhri
AKArash Kardan
Arash Kardan
ASArkadiusz Sitek
Arkadiusz Sitek
SDSharmila Dorbala
Sharmila Dorbala
NANathalie Abi-Hatem
Nathalie Abi-Hatem
MCMarcelo F. Di Carli
Marcelo F. Di Carli
82Rb cardiac PET allows the assessment of myocardial perfusion with a column generator in clinics that lack a cyclotron. There is evidence that the quantitation of myocardial blood flow (MBF) and coronary flow reserve (CFR) with dynamic 82Rb PET is feasible. The objectives of this study were to determine the accuracy and reproducibility of MBF estimates from dynamic 82Rb PET by using our methodology for generalized factor analysis (generalized factor analysis of dynamic sequences [GFADS]) and compartment analysis. Methods: Reproducibility was evaluated in 22 subjects undergoing dynamic rest and dipyridamole stress 82Rb PET studies at a 2-wk interval. The inter- and intraobserver variability of MBF quantitation with dynamic 82Rb PET was assessed with 4 repeated estimations by each of 4 observers. Accuracy was evaluated in 20 subjects undergoing dynamic rest and dipyridamole stress PET studies with 82Rb and 13N-ammonia, respectively. The left ventricular and right ventricular blood pool and left ventricular tissue time–activity curves were estimated by GFADS. MBF was estimated by fitting the blood pool and tissue time–activity curves to a 2-compartment kinetic model for 82Rb and to a 3-compartment model for 13N-ammonia. CFR was estimated as the ratio of peak MBF to baseline MBF. Results: The reproducibility of the MBF estimates in repeated 82Rb studies was very good at rest and during peak stress (R2= 0.935), as was the reproducibility of the CFR estimates (R2 = 0.841). The slope of the correlation line was very close to one for the estimation of MBF (0.986) and CFR (0.960) in repeated 82Rb studies. The intraobserver reliability was less than 3% for the estimation of MBF at rest and during peak stress as well as for the estimation of CFR. The interobserver reliabilities were 0.950 at rest and 0.975 at peak stress. The correlation between myocardial flow estimates obtained at rest and those obtained during peak stress in 82Rb and 13N-ammonia studies was very good (R2 = 0.857). Bland–Altman plots comparing CFR estimated with 82Rb and CFR estimated with 13N-ammonia revealed an underestimation of CFR with 82Rb compared with 13N-ammonia; the underestimation was within ±1.96 SD. Conclusion: MBF quantitation with GFADS and dynamic 82Rb PET demonstrated excellent reproducibility as well as intra- and interobserver reliability. The accuracy of the absolute quantitation of MBF with factor and compartment analyses and dynamic 82Rb PET was very good, compared with that achieved with 13N-ammonia, for MBF of up to 2.5 mL/g/min.

11 April 2013 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
SBSimona Ben-Haim
Simona Ben-Haim
VMVenkatesh L. Murthy
Venkatesh L. Murthy
CBChristopher Breault
Christopher Breault
RARayjanah Allie
Rayjanah Allie
ASArkadiusz Sitek
Arkadiusz Sitek
MCMarcelo F. Di Carli
Marcelo F. Di Carli
Myocardial perfusion imaging (MPI) is well established in the diagnosis and workup of patients with known or suspected coronary artery disease (CAD); however, it can underestimate the extent of obstructive CAD. Quantification of myocardial perfusion reserve with PET can assist in the diagnosis of multivessel CAD. We evaluated the feasibility of dynamic tomographic SPECT imaging and quantification of a retention index to describe global and regional myocardial perfusion reserve using a dedicated solid-state cardiac camera. Methods: Ninety-five consecutive patients (64 men and 31 women; median age, 67 y) underwent dynamic SPECT imaging with 99mTc-sestamibi at rest and at peak vasodilator stress, followed by standard gated MPI. The dynamic images were reconstructed into 60–70 frames, 3–6 s/frame, using ordered-subsets expectation maximization with 4 iterations and 32 subsets. Factor analysis was used to estimate blood-pool time–activity curves, used as input functions in a 2-compartment kinetic model. K1 values (99mTc-sestamibi uptake) were calculated for the stress and rest images, and K2 values (99mTc-sestamibi washout) were set to zero. Myocardial perfusion reserve (MPR) index was calculated as the ratio of the stress and rest K1 values. Standard MPI was evaluated semiquantitatively, and total perfusion deficit (TPD) of at least 5% was defined as abnormal. Results: Global MPR index was higher in patients with normal MPI (n = 51) than in patients with abnormal MPI (1.61 [interquartile range (IQR), 1.33–2.03] vs. 1.27 [IQR, 1.12–1.61], P = 0.0002). By multivariable regression analysis, global MPR index was associated with global stress TPD, age, and smoking. Regional MPR index was associated with the same variables and with regional stress TPD. Sixteen patients undergoing invasive coronary angiography had 20 vessels with stenosis of at least 50%. The MPR index was 1.11 (IQR, 1.01–1.21) versus 1.30 (IQR, 1.12–1.67) in territories supplied by obstructed and nonobstructed arteries, respectively (P = 0.02). MPR index showed a stepwise reduction with increasing extent of obstructive CAD (P = 0.02). Conclusion: Dynamic tomographic imaging and quantification of a retention index describing global and regional perfusion reserve are feasible using a solid-state camera. Preliminary results show that the MPR index is lower in patients with perfusion defects and in regions supplied by obstructed coronary arteries. Further studies are needed to establish the clinical role of this technique as an aid to semiquantitative analysis of MPI.

1 November 2007 in Investigative Radiology
Verified
Journal Article
Closed access
DRDamien Rohmer
Damien Rohmer
ASArkadiusz Sitek
Arkadiusz Sitek
GGGrant T. Gullberg
Grant T. Gullberg
The human heart is composed of a helical network of muscle fibers organized to form sheets that are separated by cleavage planes responsible for the orthotropic mechanical properties of cardiac muscle. The purpose of this study is the reconstruction and visualization of these structures in 3 dimensions. Anisotropic least square filtering followed by fiber and sheet tracking techniques were applied to diffusion tensor magnetic resonance imaging data of the excised human heart. Fibers were reconstructed using the first eigenvectors of the diffusion tensors. The sheets were reconstructed using the second and third eigenvectors and visualized as surfaces. The fibers are shown to lie in sheets that have transmural structure, which correspond to histologic studies published in the literature. Quantitative measurements show that the sheets as appose to the fibers are organized into laminar orientations without dominant populations. A visualization algorithm was developed to demonstrate the complex 3-dimensional orientation of the fibers and sheets in human myocardium.

25 February 2015 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
MMMaulik D. Majmudar
Maulik D. Majmudar
VMVenkatesh L. Murthy
Venkatesh L. Murthy
RSRavi V. Shah
Ravi V. Shah
SKSwathy Kolli
Swathy Kolli
NMNegareh Mousavi
Negareh Mousavi
MCMarcelo F. Di Carli
Marcelo F. Di Carli
Patients with left ventricular systolic dysfunction frequently show abnormal coronary vascular function, even in the absence of overt coronary artery disease. Moreover, the severity of vascular dysfunction might be related to the aetiology of cardiomyopathy. We sought to determine the incremental value of assessing coronary vascular dysfunction among patients with ischaemic (ICM) and non-ischaemic (NICM) cardiomyopathy at risk for adverse cardiovascular outcomes. Coronary flow reserve (CFR, stress/rest myocardial blood flow) was quantified in 510 consecutive patients with rest left ventricular ejection fraction (LVEF) ≤45% referred for rest/stress myocardial perfusion PET imaging. The primary end point was a composite of major adverse cardiovascular events (MACE) including cardiac death, heart failure hospitalization, late revascularization, and aborted sudden cardiac death. Median follow-up was 8.2 months. Cox proportional hazards model was used to adjust for clinical variables. The annualized MACE rate was 26.3%. Patients in the lowest two tertiles of CFR (CFR ≤ 1.65) experienced higher MACE rates than those in the highest tertile (32.6 vs. 15.5% per year, respectively, P = 0.004), irrespective of aetiology of cardiomyopathy. Impaired coronary vascular function, as assessed by reduced CFR by PET imaging, is common in patients with both ischaemic and non-ischaemic cardiomyopathy and is associated with MACE.