Han Wang

Dr. Han Wang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2023 in Journal of Materials Processing Technology
Verified
Journal Article
Closed access
HWHan Wang
Han Wang
USUrara Satake
Urara Satake
TEToshiyuki Enomoto
Toshiyuki Enomoto

23 November 2023 in Journal of Materials Processing Technology
Verified
Journal Article
Closed access
HWHan Wang
Han Wang
USUrara Satake
Urara Satake
TEToshiyuki Enomoto
Toshiyuki Enomoto

7 May 2022 in CIRP Annals
Verified
Journal Article
Closed access
HWHan Wang
Han Wang
USUrara Satake
Urara Satake
TEToshiyuki Enomoto
Toshiyuki Enomoto

22 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
HIHirotatsu Imai
Hirotatsu Imai
HWHan Wang
Han Wang
KKKoki Kishimoto
Koki Kishimoto
KKKosuke Kita
Kosuke Kita
YSYuki Suzuki
Yuki Suzuki
TFTakahito Fujimori
Takahito Fujimori
Purpose: Excessive drill advancement after cortical breakthrough is a potential safety concern in orthopaedic procedures. We developed a data-driven approach to estimate the drill-tip position relative to the far cortex prior to breakthrough using time-series thrust force and spindle torque signals. Methods: Drilling experiments were performed on 268 porcine cortical bone specimens at a constant feed rate of 0.5 mm/s. A long short-term memory network was trained to estimate the drill-tip position from filtered force and torque signals. The reference position was derived from breakthrough timing confirmed by high-speed imaging and the programmed feed rate. Performance was evaluated using mean absolute error within the −2 to +2 mm peri-breakthrough interval. Two post hoc analyses examined whether model performance exceeded an elapsed-time baseline and whether pre-breakthrough force patterns were more consistent when expressed relative to breakthrough position than to drilling onset time. Results: The combined-input LSTM achieved an MAE of 0.20 mm, compared with 0.23 mm for force alone and 0.24 mm for torque alone. Among the representative architectures evaluated, LSTM showed the lowest regression error. A signal-blind time-only baseline yielded an MAE of 0.54 mm. The association between cortical thickness and force-decline onset was weaker when expressed in spatial coordinates relative to breakthrough than when expressed as time from drilling onset (R2 = 23% vs. 74%). These findings suggest that force and torque signals contained information associated with proximity to breakthrough beyond that provided by average drilling duration alone. Conclusion: Converting sensor-derived resistance patterns into spatially anchored positional information may support proactive strategies such as controlled deceleration before penetration. The proposed approach represents a step toward exemplifying the emerging concept of surgeon-assisting Physical AI.

19 October 2026 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
HWHan Wang
Han Wang
USUrara Satake
Urara Satake
TEToshiyuki Enomoto
Toshiyuki Enomoto