Julieta Anahí Rancati

Dr. Julieta Anahí Rancati

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2025 in Research Square
Verified
Preprint
Open access
PDF file
ABAbla Bedoui
Abla Bedoui
JRJulieta Anahí Rancati
Julieta Anahí Rancati
ILIgnacio LUGONES
Ignacio LUGONES
MCMohammed Cherkaoui
Mohammed Cherkaoui
Background : Automated segmentation of the left and right ventricles (LV) and (RV) in cine cardiac MRI (CMR) underpins reliable volumetry and mass estimation. However, papillary muscles and trabeculae (PM/T) introduce clinically meaningful variability and exacerbate cross-dataset domain shift. Methods : We present VentrEX, an anatomically guided pipeline. The core segmenter, VentrEX-Seg is a 3D encoder-decoder with {parallel channel-spatial attention} and a {Transformer} bottleneck. Training is performed exclusively on ACDC. A lightweight PM/T module automatically extracts papillary and trabecular burden and standardizes cavity volumes. External evaluation is {zero-shot} (no fine-tuning) on Sunnybrook (LV) and MM-WHS MRI (RV). We report Dice, HD95 (mm); for volumetry we use Bland-Altman analyses (LV and RV volumes). Attention/Grad-CAM visualizations support interpretability. Results : On ACDC, VentrEX achieved higher Dice and lower boundary error than U-Net, nnU-Net, CBAM, and VentrEX-Seg. Zero-shot performance was preserved externally (e.g., Sunnybrook LV Dice~0.9053, HD95~4.95\,mm; MM-WHS RV Dice~0.9236, HD95~6.61\,mm). PM/T standardization reduced volumetric bias and narrowed limits of agreement in Bland-Altman analyses. Qualitative overlays and 3D reconstructions showed fewer PM/T "leaks" and anatomically plausible borders across ED/ES. Conclusions : Single-source training with dual zero-shot external tests demonstrates robustness under domain shift, while explicit PM/T modeling reduces volume bias and improves reproducible volumetry. The combination of parallel attention and a Transformer bottleneck enables accurate, transparent cine-CMR segmentation across datasets.

3 September 2026 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
ABAbla Bedoui
Abla Bedoui
JRJulieta Anahí Rancati
Julieta Anahí Rancati
ILIgnacio LUGONES
Ignacio LUGONES
MCMohammed Cherkaoui
Mohammed Cherkaoui
Automated segmentation of the left and right ventricles (LVs and RVs) in cine cardiac MRI (CMR) underpins reliable volumetry and mass estimation. However, papillary muscles and trabeculae (PM/T) introduce clinically meaningful variability and exacerbate cross-dataset domain shift. We present VentrEX, an anatomically guided pipeline. The core segmenter, VentrEX-Seg, is a 3D encoder-decoder with parallel channel-spatial attention and a Transformer bottleneck. Training is performed exclusively on ACDC. A lightweight PM/T module automatically extracts papillary and trabecular burdens and standardizes cavity volumes. External evaluation is zero-shot (no fine-tuning) on Sunnybrook (LV) and MM-WHS MRI (RV). We report Dice, HD95 (mm); for volumetry, we use Bland-Altman analyses (LV and RV volumes). Attention/Grad-CAM visualizations support interpretability. On ACDC, VentrEX achieved higher Dice and lower boundary error than U-Net, nnU-Net, CBAM, and VentrEX-Seg. Zero-shot performance was preserved externally (e.g., Sunnybrook LV Dice 0.9053, HD95 4.95 mm; MM-WHS RV Dice 0.9236, HD95 6.61 mm). Patient-level Bland–Altman analyses characterized LV and RV volumetric agreement. Qualitative overlays and 3D reconstructions showed fewer PM/T “leaks” and anatomically plausible borders across ED/ES. Single-source training with dual zero-shot external tests demonstrates robustness under domain shift. The combination of parallel attention and a Transformer bottleneck enables accurate, transparent cine-CMR segmentation across datasets.