Suresh K

Dr. Suresh K


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
KSK. Saravanan
K. Saravanan
GJG. Jayalakshmi
G. Jayalakshmi
SKSuresh K
Suresh K
BSB. Sundaravel
B. Sundaravel
BPB. K. Panigrahi
B. K. Panigrahi
DPD. M. Phase
D. M. Phase
We report the structural evolution of reduced graphene oxide (rGO) in graphene oxide (GO) flakes during 1 MeV Si+ ion irradiation. In-situ electrical resistivity measurements facilitate monitoring the sheet resistance with the increase in the fluence. The electrical sheet resistance of the GO flake shows the exponential decay behaviour with the increasing ion fluence. Raman spectra of the GO flake reveal the increase in the ID/IG ratio, indicating restoration of the sp2 network upon irradiation. The C/O ratio estimated from resonant Rutherford backscattering spectrometry analysis directly evidenced the reduction of oxygen moieties upon irradiation. C K–edge X-ray absorption near edge structure spectra reveal the restoration of C=C sp2–hybridized carbon atoms and the removal of oxygen-containing functional groups in the GO flake. STM data reveal the higher conductance in the rGO regime in comparison with the regime, where the oxygen functional groups are present. The experimental investigation demonstrates that the ion irradiation can be employed for efficient reduction of GO with tunable electrical and structural properties.

1 May 2018 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
SKSuresh K
Suresh K
JNJ. Navas
J. Navas
KSK. Saravanan
K. Saravanan
CDC. David
C. David
BPB.K. Panigrahi
B.K. Panigrahi

1 February 2018 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
SKSuresh K
Suresh K
SBS. Balaji
S. Balaji
KSK. Saravanan
K. Saravanan
JNJ. Navas
J. Navas
CDC. David
C. David
BPB.K. Panigrahi
B.K. Panigrahi
We developed a simple, low cost user-friendly automated indirect ion beam fluence measurement system for ion irradiation and analysis experiments requiring indirect beam fluence measurements unperturbed by sample conditions like low temperature, high temperature, sample biasing as well as in regular ion implantation experiments in the ion implanters and electrostatic accelerators with continuous beam. The system, which uses simple, low cost, off-the-shelf components/systems and two distinct layers of in-house built softwarenot only eliminates the need for costly data acquisition systems but also overcomes difficulties in using properietry software. The hardware of the system is centered around a personal computer, a PIC16F887 based embedded system, a Faraday cup drive cum monitor circuit, a pair of Faraday Cups and a beam current integrator and the in-house developed software include C based microcontroller firmware and LABVIEW based virtual instrument automation software. The automatic fluence measurement involves two important phases, a current sampling phase lasting over 20–30 seconds during which the ion beam current is continuously measured by intercepting the ion beam and the averaged beam current value is computed. A subsequent charge computation phase lasting 700–900 seconds is executed making the ion beam to irradiate the samples and the incremental fluence received by the sampleis estimated usingthe latest averaged beam current value from the ion beam current sampling phase. The cycle of current sampling-charge computation is repeated till the required fluence is reached. Besides simplicity and cost-effectiveness, other important advantages of the developed system include easy reconfiguration of the system to suit customisation of experiments, scalability, easy debug and maintenance of the hardware/software, ability to work as a standalone system. The system was tested with different set of samples and ion fluences and the results were verified using Rutherford backscattering technique which showed the satisfactory functioning of the system. The accuracy of the fluence measurements is found to be less than 2% which meets the demands of the irradiation experiments undertaken using the developed set up. The system was incorporated for regular use at the existing ultra high vacuum (UHV) ion irradiation chamber of 1.7 MV Tandem accelerator and several ion implantation experiments on a variety of samples like SS304, D9, ODS alloys have been successfully carried out.

1 May 2020 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
SKSuresh K
Suresh K
JNJ. Navas
J. Navas
BSB. Sundaravel
B. Sundaravel
JPJ. Pradhan
J. Pradhan
CDC. David
C. David
SAS.K. Albert
S.K. Albert
This paper presents the details of a personal computer (PC) based automation of ion beam analysis and ion implantation experimental setup that has been developed and implemented in a 1.7 MV Tandetron accelerator. Hardware and software of the PC automated system were designed to automate multiple sample ion implantation, standard Rutherford Backscattering spectrometry (RBS), and High resolution Rutherford Backscattering spectrometry (Hi-RBS) experiments. The system uses in-house developed signal conditioning circuitry, isolation amplifiers, and transistor drivers along with cost-effective and off-the-shelf commercial components like a general purpose, multifunction data acquisition card, etc. A five axis goniometer is used for handling multiple samples and their automatic positioning according to the commands from the PC over RS232 interface. Key tasks carried out in the automation of system include control and mesurement of ion beam fluence, selection of backscattered particles through screening of their energies by controlling a set of +/−25 kV and −3 kV high voltage power supplies, controlled collection of backscattered yield using single and multi channel analysers, controlling the region-of-interest windows in the energy spectra and the cumulative counts in them. Controlling the position of the samples and facilitating the experiments on multiple samples, online display of energy spectra and its auto storage, and vacuum interlocking are also automatically done. This PC based setup has been automated using a windows based LabVIEW software making it easy to port the set up between different computer operating systems apart from achieving many other advantages like quick and easy development of versatile, multi-purpose, and user friendly graphical interface. Extensive tests carried out on the hardware established correct functioning of various modules of the hardware. The 0–10 V control inputs applied to the +/−25 kV and −3 kV high voltage power supplies were tested and seen providing an <0.1% accuracy, <0.05% linearity, very low drift of 50 ppm, 0.01% precision, and <1mv rms output noise. The software modules have been tested to check independent control and monitoring the irradiated dose, energy to voltage conversion, the multi channel analyser control in addition to other tasks such as computing the region-of-interest counts. The fluence computed from the pulse counts from the ion beam current integrator and the actual fluence were found to be matching within 0.1%. The vacuum interlocking scheme was tested covering a range of 10−5 mbar to 10−9 mbar. Hi-RBS was carried out on a 3 nm thick Ag film grown on Si substrate using 0.3 MeV H+ ion beam over a backscattered energy range of 10–300 keV for a fixed ion fluence 2 × 1012 ions/cm2 at each energy. The recorded spectrum showed well separated Si edge and Ag peaks. The energy resolution is calculated to be 1.2 keV and a relative energy resolution (ΔE/E) of ~0.4% is obtained.

1 September 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
SKSuresh K
Suresh K
JNJ. Navas
J. Navas
RGR. Govindaraj
R. Govindaraj
In this paper, the development of simple, low cost, user-friendly microcontroller-based instrumentation for versatile applications in accelerator-based materials research has been presented. The design, development and optimization details pertaining to six in-house developed and microcontroller based automated experimental systems are discussed in detail along with an analysis of the individual systems, their lab and field performances and applications. Various lab and field tests of the systems show their excellent and comparable performances when compared to the costly commercial systems. Several novel features provided by the developed systems like uniform charge/pulse, multi-channel measurement, large counter capacity implementation, etc using simple hardware and software counters are not only very useful in day-to-day operations of the ion accelerators/implanters and simplify optimization of their operations but also help to overcome many limitations of existing/commercial electronics and instrumentation used with them. In these developments, use of off-the-shelf components/systems and in-house built firmwares not only eliminates the need for costly data acquisition systems but also overcomes difficulties in using properietry software and hardware. Apart from simplicity and cost-effectiveness, other important advantages of the developments include easy configuration of the systems to suit customisation of experiments, scalability, easy debug and maintenance of the hardware/software,ability to work as a standalone unit as well as amenability for PC control. The developed systems are regularly used in a wide ranging of applications ranging from ion implanter and electrostatic accelerator control and monitoring to ion irradiation and analysis experiments involving a range of materials used in nuclear and other industries such SS-304, D9,ODS, and 2D materials. It is also shown that this kind development can be done by individuals, small research groups and others to meet their experimental demands with this type of simple microcontroller-based instrumentation and systems.

1 October 2026 in Journal of Instrumentation
Verified
Journal Article
Closed access
SKSuresh K
Suresh K
JNJ. Navas
J. Navas
RGR. Govindaraj
R. Govindaraj
This paper presents the indigenous design and development details of electronics and instrumentation for a versatile, scalable and cost-effective control and monitoring system for a 1.7 MV electrostatic ion accelerator. The personal computer (PC) based control and monitoring system was developed using fiber-optic communication to provide complete electrical isolation, ensuring noise immunity, high-voltage isolation, and reliable high-speed data transfer. The PC based control system enables fast response (1–20 ms), reliable operation, and efficient tuning of stable light- and heavy-ion beams through user-friendly control of numerous accelerator parameters. It features a modular, scalable, and vendor-independent architecture for easy maintenance, upgrades, and integration with beam diagnostics and experimental systems. The control system developed demonstrated high control accuracy (within 0.1 %), low offset errors (2–5 mV), analog update rates of 25–28 Hz, long-term stability, and rapid response for status updates, control signal transfer, and interlock operation (Gate Valve/Faraday cup status update: 0.16 ms, digital control signal transfer: ∼1.5 ms, interlock response: 2.5–3 ms). A high-resolution embedded controller provides 0.002 % control and 0.02 % monitoring resolution for critical accelerator parameters, while an independent PLC-based interlock system ensures continuous safety supervision and automatic fault protection. It also incorporates continuous vacuum health monitoring, expandable subsystem integration, advanced LabVIEW-based software for automation and fault management, and enhanced safety through multi-level authentication, hardware key switches, uninterrupted power supply (UPS)-backed operation, and automatic safe-state transitions during power failures. The developed control system demonstrated high precision, accuracy, and reliability for accelerator operation, ion implantation, and ion beam characterization experiments ranging from milliseconds to several days. Automation of startup, shutdown, and beam tuning procedures reduced experimental setup time from hours to minutes, significantly lowering operator workload while increasing throughput, efficiency, and performance for both single-sample and batch experiments. Implemented using low-cost, off-the-shelf components and LabVIEW-based virtual instrumentation, the control system avoids dependence on proprietary hardware and software while providing flexibility, scalability, ease of debugging and maintenance, standalone operation, and cross-platform portability.