Ali Atiyah Derbishi

Dr. Ali Atiyah Derbishi


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2026 in Surgeries
Verified
Journal Article
Open access
PDF file
ADAli Atiyah Derbishi
Ali Atiyah Derbishi
FAFatima Ali Alsuaibi
Fatima Ali Alsuaibi
MAMohammed Ali Alshehri
Mohammed Ali Alshehri
AAAlia Abdullah Alassiri
Alia Abdullah Alassiri
RARama Faisal AlQahtani
Rama Faisal AlQahtani
YGYasser Al Ghadyan
Yasser Al Ghadyan
Background/Objectives: Conventional manually bent titanium plates remain the standard for fixation in orthognathic surgery, whereas patient-specific implants (PSIs), additively manufactured plates, or stock plates pre-bent on a printed model, usually delivered within a guide-based, splintless workflow, aim to eliminate intraoperative plate adaptation and improve transfer of the virtual plan. This systematic review and meta-analysis compared PSIs with conventional plates for three-dimensional (3D) accuracy, skeletal stability, operative efficiency, and complications. Methods: PubMed, Embase, CENTRAL, Scopus, Web of Science, LILACS, and grey literature were searched from inception to 28 August 2026 for randomized controlled trials (RCTs) and non-randomized studies of interventions (NRSIs). Data were pooled with random-effects models (restricted maximum likelihood with Hartung–Knapp–Sidik–Jonkman adjustment). Risk of bias was assessed with RoB 2 and ROBINS-I, and certainty with GRADE. The protocol was submitted to PROSPERO. Results: Thirty-three studies (10 RCTs, 23 NRSIs) were included. All poolable accuracy data came from additively manufactured PSIs. PSIs probably reduce global 3D positional deviation (MD −0.50 mm; 95% CI −0.69 to −0.31; p = 0.0006; moderate certainty), a sub-millimeter difference below accepted clinical thresholds, and may improve pooled accuracy (SMD −0.71; 95% CI −0.95 to −0.47; low certainty), with smaller anteroposterior and yaw errors (very low and low certainty, respectively). Mean skeletal relapse at the longest follow-up did not differ (very low certainty). A single non-randomized cohort of patients with cleft lip and palate (n = 63) reported less relapse ≥ 1 mm at one year with PSIs (horizontal RR 0.09; vertical RR 0.07; very low certainty); this finding cannot be generalized to non-cleft patients. One cohort reported fewer dental root injuries with PSIs (RR 0.06; very low certainty); infection and wound complications did not differ (RR 0.74; 95% CI 0.37 to 1.47; very low certainty). Operative-time results were inconsistent across three small studies (I2 = 95%), and no reliable summary estimate could be derived. A higher hardware-removal rate was observed in the PSI arm of one era-confounded cohort (RR 2.13), which cannot be interpreted as causal evidence of a higher intrinsic removal risk. Conclusions: Additively manufactured PSIs probably improve 3D accuracy by about half a millimeter, a statistically significant but sub-millimeter gain that does not by itself establish a patient-centered benefit for routine cases. Possible reductions in clinically relevant relapse and dental root injury each rest on a single study of very low certainty and require confirmation. These uncertain benefits must be weighed against cost, preoperative lead time, and an evidence base of predominantly low to very low certainty in which several included comparisons tested an entire guide-based splintless workflow rather than the plate alone.

31 August 2026 in Surgeries
Verified
Journal Article
Open access
PDF file
ADAli Atiyah Derbishi
Ali Atiyah Derbishi
RARaand Abdulmohsen Altayyar
Raand Abdulmohsen Altayyar
AAAbdulaziz Saad AlSubaiei
Abdulaziz Saad AlSubaiei
RARazan Alghannam
Razan Alghannam
RSRakan Sbitan
Rakan Sbitan
LALaila Saud Alghamdi
Laila Saud Alghamdi
Background/Objectives: Maxillary sinus floor augmentation (MSFA) is a predictable procedure for the rehabilitation of the atrophic posterior maxilla. The prolonged healing time associated with particulate bone grafts poses a clinical challenge. This review aimed to evaluate the clinical, radiographic, and histomorphometric efficacy of autologous platelet-rich fibrin (PRF) combined with bone grafts versus bone grafts alone in MSFA. Methods: A search of databases was conducted until May 2026. We included randomized controlled trials, controlled clinical trials, and cohort studies. Random-effects meta-analyses were performed for new bone formation (NFB%), residual graft (RG%), implant stability quotient (ISQ), and vertical bone height gain. The certainty of the evidence was appraised using the GRADE framework. Results: Thirty-two studies encompassing 728 augmented sinuses in 563 patients met the inclusion criteria. The adjunctive use of PRF significantly increased NFB% (MD = 4.10%; 95% CI: 1.59–6.61; p = 0.005; 10 studies; 204 sinuses; I2 = 20.9%; moderate certainty of evidence), with a 95% prediction interval that excluded the null. No statistically significant difference was demonstrated for RG% (MD = −2.71%; 95% CI: −6.08–0.67; p = 0.103; 10 studies; 204 sinuses; I2 = 45.2%; very low certainty of evidence), the latter estimate being sensitive to the omission of individual studies. Exploratory subgroup analyses are reported as hypothesis-generating only; the significant between-subgroup contrasts for residual graft were generated by strata containing a single study each. There were no statistically significant differences in ISQ (MD = 1.74; 95% CI: −4.38–7.86; p = 0.432; 4 studies; 140 implants; I2 = 92.1%) or vertical bone height gain (MD = −0.35 mm; 95% CI: −2.82–2.13; p = 0.687); both outcomes exhibited substantial heterogeneity and very low certainty of evidence, and their CIs remain compatible with a clinically relevant benefit. Conclusions: The incorporation of PRF into particulate bone grafts during MSFA enhances histological graft maturation by increasing NFB, without a demonstrable effect on RG. This histomorphometric benefit did not translate to improvements in radiographic bone height, bone density, or early implant stability, although the evidence for these outcomes remains imprecise. Therefore, PRF may be regarded as a low-cost autologous adjunct where accelerated histological graft maturation is the specific objective, but the present evidence does not justify a general recommendation for its routine use.