Virginia Pensabene

Dr. Virginia Pensabene

School of Electrical and Electronic Engineering, University of Leeds, Leeds, UK
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Biomicrofluidics
Verified
Journal Article
Open access
PDF file
JBJacquelyn A. Brown
Jacquelyn A. Brown
VPVirginia Pensabene
Virginia Pensabene
DMDmitry A. Markov
Dmitry A. Markov
Vanessa AllwardtVanessa Allwardt
Vanessa Allwardt
MNM. Diana Neely
M. Diana Neely
JWJohn P. Wikswo
John P. Wikswo
The blood-brain barrier (BBB) is a critical structure that serves as the gatekeeper between the central nervous system and the rest of the body. It is the responsibility of the BBB to facilitate the entry of required nutrients into the brain and to exclude potentially harmful compounds; however, this complex structure has remained difficult to model faithfully in vitro. Accurate in vitro models are necessary for understanding how the BBB forms and functions, as well as for evaluating drug and toxin penetration across the barrier. Many previous models have failed to support all the cell types involved in the BBB formation and/or lacked the flow-created shear forces needed for mature tight junction formation. To address these issues and to help establish a more faithful in vitro model of the BBB, we have designed and fabricated a microfluidic device that is comprised of both a vascular chamber and a brain chamber separated by a porous membrane. This design allows for cell-to-cell communication between endothelial cells, astrocytes, and pericytes and independent perfusion of both compartments separated by the membrane. This NeuroVascular Unit (NVU) represents approximately one-millionth of the human brain, and hence, has sufficient cell mass to support a breadth of analytical measurements. The NVU has been validated with both fluorescein isothiocyanate (FITC)-dextran diffusion and transendothelial electrical resistance. The NVU has enabled in vitro modeling of the BBB using all human cell types and sampling effluent from both sides of the barrier.

28 February 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SBSimone Benedetto
Simone Benedetto
CCChristian Caldato
Christian Caldato
EBElia Bazzan
Elia Bazzan
DGDarren Greenwood
Darren Greenwood
VPVirginia Pensabene
Virginia Pensabene
PAPaolo Actis
Paolo Actis
Fitness trackers are devices or applications for monitoring and tracking fitness-related metrics such as distance walked or run, calorie consumption, quality of sleep and heart rate. Since accurate heart rate monitoring is essential in fitness training, the objective of this study was to assess the accuracy and precision of the Fitbit Charge 2 for measuring heart rate with respect to a gold standard electrocardiograph. Fifteen healthy participants were asked to ride a stationary bike for 10 minutes and their heart rate was simultaneously recorded from each device. Results showed that the Fitbit Charge 2 underestimates the heart rate. Although the mean bias in measuring heart rate was a modest -5.9 bpm (95% CI: -6.1 to -5.6 bpm), the limits of agreement, which indicate the precision of individual measurements, between the Fitbit Charge 2 and criterion measure were wide (+16.8 to -28.5 bpm) indicating that an individual heart rate measure could plausibly be underestimated by almost 30 bpm.

20 January 2017 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
JGJuan S. Gnecco
Juan S. Gnecco
VPVirginia Pensabene
Virginia Pensabene
DLDavid J. Li
David J. Li
TDTianbing Ding
Tianbing Ding
EHElliot E Hui
Elliot E Hui
KOKevin G. Osteen
Kevin G. Osteen
The endometrium is the inner lining of the uterus. Following specific cyclic hormonal stimulation, endometrial stromal fibroblasts (stroma) and vascular endothelial cells exhibit morphological and biochemical changes to support embryo implantation and regulate vascular function, respectively. Herein, we integrated a resin-based porous membrane in a dual chamber microfluidic device in polydimethylsiloxane that allows long term in vitro co-culture of human endometrial stromal and endothelial cells. This transparent, 2-μm porous membrane separates the two chambers, allows for the diffusion of small molecules and enables high resolution bright field and fluorescent imaging. Within our primary human co-culture model of stromal and endothelial cells, we simulated the temporal hormone changes occurring during an idealized 28-day menstrual cycle. We observed the successful differentiation of stroma into functional decidual cells, determined by morphology as well as biochemically as measured by increased production of prolactin. By controlling the microfluidic properties of the device, we additionally found that shear stress forces promoted cytoskeleton alignment and tight junction formation in the endothelial layer. Finally, we demonstrated that the endometrial perivascular stroma model was sustainable for up to 4 weeks, remained sensitive to steroids and is suitable for quantitative biochemical analysis. Future utilization of this device will allow the direct evaluation of paracrine and endocrine crosstalk between these two cell types as well as studies of immunological events associated with normal vs. disease-related endometrial microenvironments.

1 March 2017 in Reproductive Toxicology
Verified
Journal Article
Open access
KBKaylon L Bruner-Tran
Kaylon L Bruner-Tran
JGJuan Gnecco
Juan Gnecco
TDTianbing Ding
Tianbing Ding
DGDana R. Glore
Dana R. Glore
VPVirginia Pensabene
Virginia Pensabene
KOKevin G. Osteen
Kevin G. Osteen
Humans and other animals are exposed to a wide array of man-made toxicants, many of which act as endocrine disruptors that exhibit differential effects across the lifespan. In humans, while the impact of adult exposure is known for some compounds, the potential consequences of developmental exposure to endocrine disrupting chemicals (EDCs) is more difficult to ascertain. Animal studies have revealed that exposure to EDCs prior to puberty can lead to adult reproductive disease and dysfunction. Specifically, in adult female mice with an early life exposure to 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), we demonstrated a transgenerational occurrence of several reproductive diseases that have been linked to endometriosis in women. Herein, we review the evidence for TCDD-associated development of adult reproductive disease as well as known epigenetic alterations associated with TCDD and/or endometriosis. We will also introduce new "Organ-on-Chip" models which, combined with our established murine model, are expected to further enhance our ability to examine alterations in gene-environment interactions that lead to heritable disease.

1 April 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
AOAlfredo Edoardo Ongaro
Alfredo Edoardo Ongaro
DGDavide Di Giuseppe
Davide Di Giuseppe
AKAli Kermanizadeh
Ali Kermanizadeh
ACAllende Miguelez Crespo
Allende Miguelez Crespo
AMArianna Mencattini
Arianna Mencattini
MKMaiwenn KERSAUDY-KERHOAS
Maiwenn KERSAUDY-KERHOAS

16 September 2020 in Bioengineering
Verified
Journal Article
Open access
PDF file
Vanessa AllwardtVanessa Allwardt
Vanessa Allwardt
AAAlexander J. Ainscough
Alexander J. Ainscough
PVPriyalakshmi Viswanathan
Priyalakshmi Viswanathan
SSStacy D. Sherrod
Stacy D. Sherrod
JMJohn McLean
John McLean
VPVirginia Pensabene
Virginia Pensabene
Organs-on-a-Chip (OOAC) is a disruptive technology with widely recognized potential to change the efficiency, effectiveness, and costs of the drug discovery process; to advance insights into human biology; to enable clinical research where human trials are not feasible. However, further development is needed for the successful adoption and acceptance of this technology. Areas for improvement include technological maturity, more robust validation of translational and predictive in vivo-like biology, and requirements of tighter quality standards for commercial viability. In this review, we reported on the consensus around existing challenges and necessary performance benchmarks that are required toward the broader adoption of OOACs in the next five years, and we defined a potential roadmap for future translational development of OOAC technology. We provided a clear snapshot of the current developmental stage of OOAC commercialization, including existing platforms, ancillary technologies, and tools required for the use of OOAC devices, and analyze their technology readiness levels. Using data gathered from OOAC developers and end-users, we identified prevalent challenges faced by the community, strategic trends and requirements driving OOAC technology development, and existing technological bottlenecks that could be outsourced or leveraged by active collaborations with academia.