In this paper, a traveling wave based fault location method is proposed for distribution networks. Before fault occurs, an intrinsic distance difference matrix (IDDM) is established based on the characteristics of traveling wave propagation and the topology of distribution network. After the fault, the initial fault traveling wave signals are decomposed into several intrinsic mode function (IMF) signals by variational mode decomposition (VMD), and the first IMF signal is analyzed by teager energy operator (TEO) to determine the arriving time of initial fault traveling waves. According to the double-ended traveling wave method and the arrival time of traveling wave at all recorders, a fault distance difference matrix (FDDM) is built. By comparing the difference between IDDM and FDDM, a fault branch determination matrix (FBDM) and the lateral index Q are used to locate the fault. The effectiveness of the proposed method is verified via EMTP/ATP simulations. Results show that the proposed method has a high fault location accuracy, and does not need that all terminals of lines are installed traveling wave recorders.
The power system has become the key target of national cyber confrontation. To enhance the risk management capability of the distribution network (DN) while assessing the cyberattack risk quickly and accurately, this paper proposes a general real-time cyberattack risk assessment method for DN involving the influence of distributed feeder automation systems (DFAs). In particular, to clarify the quantitative relationship between cyberattack intrusion and DN state deterioration, we constructed the quantitative model of the cyber physical distribution network (CPDN) under cyberattack, which involves the influence of DFAs’ behavior. In addition, in order to intuitively demonstrate the cyberattack risk, we developed a novel entropy-like risk assessment system upon the quantitative model of CPDN. The real two-feeder test platform with cyberattack simulation devices is used to verify the correctness and practicality of the proposed method. In this process, a digital cyberattack risk assessment unit is created, contributing to the system-level application of risk management.
In order to reduce the influence of environmental noise and different operating conditions on the accuracy of motor fault diagnosis, this paper proposes a capsule network method combining multi-channel signals and the efficient channel attention (ECA) mechanism, sampling the data from multiple sensors and visualizing the one-dimensional time-frequency domain as a two-dimensional symmetric dot pattern (SDP) image, then fusing the multi-channel image data and extracting the image using a capsule network combining the ECA attention mechanism features to match eight different fault types for fault classification. In order to guarantee the universality of the suggested model, data from Case Western Reserve University (CWRU) is used for validation. The suggested multi-channel signal fusion ECA attention capsule network (MSF-ECA-CapsNet) model fault identification accuracy may reach 99.21%, according to the experimental findings, which is higher than the traditional method. Meanwhile, the method of multi-sensor data fusion and the use of the ECA attention mechanism make the diagnosis accuracy much higher.
1 January 2020 in CSEE Journal of Power and Energy Systems
Electromagnetic vibration and noise issues of converter transformers under harmonic operating conditions have become increasingly prominent. To enable a systematic comparison of different filtering strategies, this paper establishes a multiphysical field coupling model incorporating electromagnetic, structural, and acoustic fields, and systematically investigates four filtering configurations: grid-side LC filtering, valve-side LC filtering, inductive filtering, and valve-side capacitive filtering through theoretical analysis, finite-element simulation, and experimental verification on a 12-pulse laboratory HVDC prototype platform. The simulation results show that the maximum vibration acceleration decreases from 3.06 m/s2 under the no-filter condition to 1.02 m/s2 under valve-side capacitive filtering. Experimental measurements further confirm the suppression effect, with the vibration acceleration at Point 8 decreasing from 2.28 m/s2 to 0.42 m/s2, corresponding to a reduction of approximately 82%, while the average A-weighted sound pressure level decreases from 66.1 dB to 58.1 dB. These results indicate that vibration and noise suppression cannot be evaluated solely by total harmonic distortion; the attenuation and distribution of individual harmonic components should also be considered. The findings provide a theoretical and engineering basis for the vibration and noise reduction design of converter transformers.