Axel Gänsslen

Dr. Axel Gänsslen


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2013 in Acta Chirurgiae Orthopaedicae Et Traumatologiae Cechoslovaca
Verified
Journal Article
Closed access
PDF file
AGAxel Gänsslen
Axel Gänsslen
FHF. Hildebrand
F. Hildebrand
CKC. Krettek
C. Krettek
PURPOUSE OF THE STUDY: Pelvic ring fractures in the geriatric population are of increasing frequency. Often insufficiency fractures or occult fractures are described. With a classical injury mechanism the majority of these injuries are the result of a low energy trauma, typically a fall from standing or during walking.Clinically, many patients report immediate anterior groin pain but detailed clinical examination often shows significant posterior pelvic pain. CT evaluation often reveals posterior pelvic ring injury, in the majority of cases a sacral compression fracture. Despite adequate diagnostics, many of these patients suffer from persistent pain, which can be observed up to 8 weeks after injury. To asses the role of external fixator in pain relief and early mobilisation in this group of patients the study was performed. From the database of all patients with pelvic ring and acetabular injuries 25 patients > 65 years with type B injuries stabilized by a supraacetabular external fixator were analyzed. Prospectively demographic data including sex, patient age, cause of injury, frequency and type of concomitant injuries and diseases, injury severity,fracture type and complications were recorded. For evaluation of the pain course, the visual analog scale was used. Preoperative and postoperative mobility and the type of post-treatment were evaluated. Stabilizing the pelvic ring with a simple external fixation procedure (supraacetabular one pin external fixator) allows immediate relief of pain, which allows early and successful mobilization of these patients. Normally, adequate mobilization is possible immediate after application of the fixator. This simple operative procedure, therefore, can be used for pain control and sufficient mobilization to avoid secondary medical complications.

20 September 2009 in Operative Orthopädie und Traumatologie
Verified
Journal Article
Closed access
AGAxel Gänsslen
Axel Gänsslen
CKChristian Krettek
Christian Krettek

1 June 2008 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
OTOmke Enno Teebken
Omke Enno Teebken
JLJachim Lotz
Jachim Lotz
AGAxel Gänsslen
Axel Gänsslen
APAndreas Maximilian Pichlmaier
Andreas Maximilian Pichlmaier
The case of an 18-year-old polytrauma patient with a complete disruption of the right external iliac artery and a dissection of the left external ili

24 March 2010 in Der Unfallchirurg
Verified
Journal Article
Closed access
PDF file
AGAxel Gänsslen
Axel Gänsslen

4 January 2025 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
AGAxel Gänsslen
Axel Gänsslen
JLJan Lindahl
Jan Lindahl
RLRichard A. Lindtner
Richard A. Lindtner
DKDietmar Krappinger
Dietmar Krappinger
MSMario Staresinic
Mario Staresinic
Adequate intraoperative visualization is mandatory for implant application in pelvic ring injuries. Several fluoroscopic X-ray views are in practical use. The gold standard primary X-ray is the anteroposterior view of the pelvis. In addition to this view, oblique views for pelvic ring instabilities and acetabular fractures are well defined. Combinations of these views allow better identification of osseous corridors for screw applications. These corridors are based on the 3-ring concept of the hemipelvis. For pelvic ring stabilization the main osseous corridors include the retrograde and antegrade superior ramus/anterior column corridor, the supraacetabular corridor and the gluteus medius pillar corridor. The radiographic anatomy of these corridors is described in detail for screw applications with definition of image intensifier angulations, risk zones and corridor parameters. This allows for intraoperative safe implant application.

21 October 2011 in Der Chirurg
Verified
Journal Article
Closed access
PDF file
AGAxel Gänsslen
Axel Gänsslen
HOH.J. Oestern
H.J. Oestern