Metodija Atanasovski

Prof. Dr. Metodija Atanasovski

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
Pande PopovskiPande Popovski
Pande Popovski
GVGoran Veljanovski
Goran Veljanovski
MAMetodija Atanasovski
Metodija Atanasovski
SPSofija Nikolova Poceva
Sofija Nikolova Poceva
ACAnton Chaushevski
Anton Chaushevski
This paper studies a risk-averse stochastic unit commitment framework for an energy aggregator, operating a portfolio of conventional generators, renewable units, and battery energy storage in a network-constrained environment. Renewable generation and demand uncertainty are represented through a scenario-based extensive-form mixed-integer linear program. To avoid exposure to rare but high cost events, the model incorporates conditional value-at-risk as part of the objective function. The approach captures key market interactions, including day-ahead commitments, imbalance penalties, and power exchange with a neighboring network, while respecting generator constraints, storage dynamics, line flow limits, and bus voltage security. A comprehensive parametric study is conducted to quantify the influence of two risk parameters: the conditional value-at-risk confidence level α and the risk-aversion weight λ. Using a 300-scenario test set on a modified IEEE 9-bus system, the results show that risk-neutral scheduling exposes the aggregator to larger operational costs in extreme scenarios. Minor levels of risk aversion (0.1–0.5) reduce CVaR and tighten the distribution of costs. Increasing λ further yields diminishing returns, while higher α values focus risk mitigation on the most severe outcomes. The results demonstrate how CVaR-based stochastic scheduling can support aggregator decision-making by quantifying downside risk under renewable uncertainty.

13 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Pande PopovskiPande Popovski
Pande Popovski
GVGoran Veljanovski
Goran Veljanovski
MAMetodija Atanasovski
Metodija Atanasovski
SPSofija Nikolova Poceva
Sofija Nikolova Poceva
ACAnton Chaushevski
Anton Chaushevski
This paper studies a risk-averse stochastic unit commitment framework for an energy aggregator, operating a portfolio of conventional generators, renewable units, and battery energy storage in a network-constrained environment. Renewable generation and demand uncertainty are represented through a scenario based extensive-form mixed-integer linear program. To avoid exposure to rare but high cost events, the model incorporates Conditional Value-at-Risk as part of the objective function. The approach captures key market interactions, including day-ahead commitments, imbalance penalties, and power exchange with a neighboring network, while respecting generator constraints, storage dynamics, line flow limits, and bus voltage security. A comprehensive parametric study is conducted to quantify the influence of two risk parameters: the Conditional Value-at-Risk confidence level α and the risk-aversion weight λ. Using a 300-scenario test set on a modified IEEE 9-bus system, the results show that risk-neutral scheduling exposes the aggregator to larger operational costs in extreme scenarios. Minor levels of risk aversion (0.1–0.5) reduce CVaR and tighten the distribution of costs. Increasing λ further yields diminishing returns, while higher α values focus risk mitigation on the most severe outcomes. The results demonstrate how CVaR-based stochastic scheduling can support aggregator decision-making by quantifying downside risk under renewable uncertainty.

14 September 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Pande PopovskiPande Popovski
Pande Popovski
GVGoran Veljanovski
Goran Veljanovski
MAMetodija Atanasovski
Metodija Atanasovski
SPSofija Nikolova Poceva
Sofija Nikolova Poceva
ACAnton Chaushevski
Anton Chaushevski
Electricity market settlement rules shape the financial exposure that energy aggregators face when generation deviates from contracted positions, yet their interaction with Conditional-Value-at-Risk-based risk-aversion strategies in aggregator scheduling remains unexplored. This paper studies how the design of imbalance penalty rules influences optimal risk-aversion in a stochastic unit commitment framework for a network-constrained aggregator operating a diversified portfolio of generation resources. Four settlement regimes are defined: a regime with halved deviation penalty rates, a baseline regime matching empirical market data, a strict regime with doubled penalty rates, and a self-balancing regime that prohibits contracted day-ahead exchange. A parametric sweep of the risk aversion weight λ at a fixed confidence level α is conducted on a modified IEEE 9-bus test system using 50 stochastic scenarios. To resolve the transition between the discrete regimes, a finer penalty sweep is also performed. Results show that stricter settlement designs increase tail-risk exposure at the risk-neutral baseline, while the benefit of risk weighting is largest under the strict and self-balancing regimes. Battery energy storage throughput responds to λ under market-participatory regimes but becomes invariant under self-balancing constraints. The findings provide quantitative guidance on how settlement regime should inform aggregator risk management strategy.

12 April 2024 in New Horizons - Journal of Student Research
Verified
Journal Article
Open access
PDF file
MIMelanija Ilova
Melanija Ilova
BGBoris Gushevski
Boris Gushevski
MAMetodija Atanasovski
Metodija Atanasovski
Batteries are an essential part of our modern lifestyle, finding application in various aspects of everyday life such as mobile devices, electric cars, renewable energy sources and many others. The technological development of batteries is continuous and fast in order to improve performance and reduce their negative impacts on the environment and society. This paper explores the technological advances of batteries through different generations and technologies, from classic lithium-ion batteries to new innovative concepts such as solid and lithium-alloy batteries. The improvement processes include improvements in the capacity, charging speed, safety and durability of the batteries, as well as the recycling of components to reduce the environmental footprint. With continued research and innovation in the field of batteries, we can expect to see significant advances in battery efficiency and sustainability, with the potential to revolutionize the way we use and store energy in the future.

27 November 2025 in B&H Electrical Engineering
Verified
Journal Article
Open access
PDF file
MAMetodija Atanasovski
Metodija Atanasovski
GVGoran Veljanovski
Goran Veljanovski
PPPande Popovski
Pande Popovski
AMAleksandra Krkoleva Mateska
Aleksandra Krkoleva Mateska
PKPetar Krstevski
Petar Krstevski
The time equivalent availability of maximum power for photovoltaics (PVs) is approximately 1500 h per year, and for the wind power plants (WPPs) it is about 3000 h per year. The maximum power generation of PVs and WPPs will occur in several hours per day depending on the season, and for the rest of the day the power will be lower or zero. As a result, the transmission and distribution lines will be highly loaded or overloaded for the previously mentioned specific hours, while during the rest of the year the loading will be lower. In order to overcome the problem of unnecessary reinforcement of lines, this paper proposes less costly operational measures using load and generation flexibility based on electrical distance. According to the Zbus matrix allocation method, the complex power flow of each branch j-k can be expressed as a function of the voltage at node j and the current injections at each node. The electrical distance coefficient matrix represents the electrical distance of the bus i from the branch j-k and it measures the impact of the bus injection on the branch j-k complex power flow. Namely, higher value of electrical distance coefficient means higher impact of the bus i injection on the power flow. The proposed algorithm in this paper uses the electrical distance and load flexibility or generation re-dispatch for solving the overloads in the network. Firstly, power flow is solved, which enables to detect the overloads in the network. After that, the Zbus matrix and the electrical coefficients matrix are calculated. We are observing the row of electrical distance coefficient matrix that corresponds to the overloaded branch(es). The maximum electrical coefficient is detected in that row and load or generator in the corresponding bus is scaled (+ or −) appropriately to solve the overloading(s). The proposed methodology will be tested on distribution and transmission network. The results will be presented and discussed.

23 October 2026 in Electricity
Verified
Journal Article
Open access
PDF file
Pande PopovskiPande Popovski
Pande Popovski
GVGoran Veljanovski
Goran Veljanovski
MAMetodija Atanasovski
Metodija Atanasovski
SPSofija Nikolova Poceva
Sofija Nikolova Poceva
ACAnton Chaushevski
Anton Chaushevski
Electricity market settlement rules shape the financial exposure of energy aggregators when generation deviates from contracted positions, yet their interaction with Conditional-Value-at-Risk (CVaR) based risk aversion in aggregator scheduling remains unexplored. This paper studies how imbalance penalty design shapes the risk–return tradeoff in a stochastic unit commitment framework for a network-constrained aggregator with a diversified generation portfolio. Five settlement regimes are compared, spanning liberal, baseline, and strict penalty levels together with two zero-contract regimes that settle all exchange as imbalance. The risk-aversion weight is swept at a fixed confidence level on a modified IEEE 9-bus system using 200 stochastic scenarios, complemented by a continuous penalty-multiplier sweep. Stricter settlement disproportionately increases tail-risk exposure at the risk-neutral baseline, with the excess tail-risk ratio rising from 49% under liberal to 89% under strict penalties. Risk weighting reduces CVaR by 1.5–7.1% for an expected-profit sacrifice of at most 1.2%, with the largest absolute reductions where baseline tail risk is highest. Battery storage throughput falls by 22–35 MWh/day under market-participatory regimes but changes by less than 5 MWh/day once the contracted position is removed, becoming effectively invariant to the risk weight. The results give quantitative guidance on how settlement regime should inform aggregator risk management.