David Hanneke

David Hanneke

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2008 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
DHDavid Hanneke
David Hanneke
SFS. Fogwell
S. Fogwell
GGG. Gabrielse
G. Gabrielse
A measurement using a one-electron quantum cyclotron gives the electron magnetic moment in Bohr magnetons, g/2=1.001 159 652 180 73 (28) [0.28 ppt], with an uncertainty 2.7 and 15 times smaller than for previous measurements in 2006 and 1987. The electron is used as a magnetometer to allow line shape statistics to accumulate, and its spontaneous emission rate determines the correction for its interaction with a cylindrical trap cavity. The new measurement and QED theory determine the fine structure constant, with α−1=137.035 999 084 (51) [0.37 ppb], and an uncertainty 20 times smaller than for any independent determination of α.

24 May 2011 in Physical Review A
Verified
Journal Article
Open access
DHDavid Hanneke
David Hanneke
SHS. Fogwell Hoogerheide
S. Fogwell Hoogerheide
GGG. Gabrielse
G. Gabrielse
Measurements with a one-electron quantum cyclotron determine the electron magnetic moment, given by g/2=1.001$\hskip0.3em${}159$\hskip0.3em${}652$\hskip0.3em${}180$\hskip0.3em${}73(28)[0.28ppt], and the fine structure constant, $\alpha${}-1=137.035$\hskip0.3em${}999$\hskip0.3em${}084(51)[0.37ppb]. Announcements of these measurements [Phys. Rev. Lett. 97, 030801 (2006); 100, 120801 (2008)] are supplemented here with a more complete description of the one-electron quantum cyclotron and the measurement methods, a discussion of the cavity control of the radiation field, a summary of the analysis of the measurements, and a fuller discussion of the uncertainties.

17 July 2006 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
BOBrian Odom
Brian Odom
DHDavid Hanneke
David Hanneke
BDB. D’uRso
B. D’uRso
GGG. Gabrielse
G. Gabrielse
A new measurement resolves cyclotron and spin levels for a single-electron quantum cyclotron to obtain an electron magnetic moment, given by g/2=1.001 159 652 180 85 (76) [0.76  ppt]. The uncertainty is nearly 6 times lower than in the past, and g is shifted downward by 1.7 standard deviations. The new g, with a quantum electrodynamics (QED) calculation, determines the fine structure constant with a 0.7 ppb uncertainty—10 times smaller than for atom-recoil determinations. Remarkably, this 100 mK measurement probes for internal electron structure at 130 GeV.

20 August 2012 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
RBR. Bowler
R. Bowler
JGJ. Gaebler
J. Gaebler
YLY. Lin
Y. Lin
TTT. R. Tan
T. R. Tan
DHDavid Hanneke
David Hanneke
DWD. J. Wineland
D. J. Wineland
We investigate the dynamics of single and multiple ions during transport between and separation into spatially distinct locations in a multizone linear Paul trap. A single Be+9 ion in a ∼2  MHz harmonic well was transported 370  μm in 8  μs, corresponding to 16 periods of oscillation, with a gain of 0.1 motional quanta. Similar results were achieved for the transport of two ions. We also separated chains of up to 9 ions from one potential well to two distinct potential wells. With two ions this was accomplished in 55  μs, with excitations of approximately two quanta for each ion. Fast transport and separation can significantly reduce the time overhead in certain architectures for scalable quantum information processing with trapped ions.

4 September 2009 in Science
Verified
Journal Article
Closed access
PDF file
Jonathan HomeJonathan Home
Jonathan Home
DHDavid Hanneke
David Hanneke
JJJohn D. Jost
John D. Jost
JAJason M. Amini
Jason M. Amini
DLDietrich Leibfried
Dietrich Leibfried
DWDavid J. Wineland
David J. Wineland
Hi Fi Quantum Computing: In quantum information processing, one goal is to control the entangled states of objects such that they can interact during logical operations but otherwise have minimal interactions with their environment. In one scheme for quantum computing, ions are trapped within and physically moved by electric fields. One drawback is that the entangled states can be sensitive to stray magnetic fields. Home et al. (p. 1227 , published online 6 August 2009) show that coupling of the ions (in this case, 9 Be + ) with a second ion ( 24 Mg + ) can create states that are relatively insensitive to magnetic fields and also allows for recooling of the ions during operation. This approach can minimize the loss of fidelity that occurs during ion transport.

26 June 2012 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
JGJ. P. Gaebler
J. P. Gaebler
AMA. M. Meier
A. M. Meier
TTT. R. Tan
T. R. Tan
RBR. Bowler
R. Bowler
YLY. Lin
Y. Lin
DWD. J. Wineland
D. J. Wineland
We describe an extension of single-qubit gate randomized benchmarking that measures the error of multiqubit gates in a quantum information processor. This platform-independent protocol evaluates the performance of Clifford unitaries, which form a basis of fault-tolerant quantum computing. We implemented the benchmarking protocol with trapped ions and found an error per random two-qubit Clifford unitary of 0.162±0.008, thus setting the first benchmark for such unitaries. By implementing a second set of sequences with an extra two-qubit phase gate inserted after each step, we extracted an error per phase gate of 0.069±0.017. We conducted these experiments with transported, sympathetically cooled ions in a multizone Paul trap—a system that can in principle be scaled to larger numbers of ions.