Joanna E. M. Scanlon

Dr. Joanna E. M. Scanlon

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Brain Research
Verified
Journal Article
Closed access
JSJoanna E. M. Scanlon
Joanna E. M. Scanlon
KTKimberley A. Townsend
Kimberley A. Townsend
DCDanielle L. Cormier
Danielle L. Cormier
JKJonathan W.P. Kuziek
Jonathan W.P. Kuziek
KMKyle E. Mathewson
Kyle E. Mathewson

1 March 2017 in Psychophysiology
Verified
Journal Article
Closed access
PDF file
JSJoanna E. M. Scanlon
Joanna E. M. Scanlon
ASAlex J. Sieben
Alex J. Sieben
KHKevin R. Holyk
Kevin R. Holyk
KMKyle E. Mathewson
Kyle E. Mathewson

13 November 2020 in European Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
JSJoanna E. M. Scanlon
Joanna E. M. Scanlon
NJNadine Svenja Josée Jacobsen
Nadine Svenja Josée Jacobsen
MMMarike C. Maack
Marike C. Maack
SDStefan Debener
Stefan Debener
It has been stated that active‐transmission electrodes should improve signal quality in mobile EEG recordings. However, few studies have directly compared active‐ and passive‐transmission electrodes during a mobile task. In this repeated measurement study, we investigated the performance of active and passive signal transmission electrodes with the same amplifier system in their respective typical configurations, during a mobile auditory task. The task was an auditory discrimination (1,000 vs. 800 Hz; counterbalanced) oddball task using approximately 560 trials (15% targets) for each condition. Eighteen participants performed the auditory oddball task both while standing and walking in an outdoor environment. While walking, there was a significant decrease in P3 amplitude, post‐trial rejection trial numbers, and signal‐to‐noise ratio (SNR). No significant differences were found in signal quality between the two electrode configurations. SNR and P3 amplitude were test‐retest reliable between recordings. We conclude that adequate use of a passive EEG electrode system achieves signal quality equivalent to that of an active system during a mobile task.

14 March 2022 in NeuroImage
Verified
Journal Article
Open access
JSJoanna E. M. Scanlon
Joanna E. M. Scanlon
NJN.S.J. Jacobsen
N.S.J. Jacobsen
MMM.C. Maack
M.C. Maack
SDS. Debener
S. Debener
Interpersonal behavioral synchrony is defined as the temporal coordination of action between two or more individuals. Humans tend to synchronize their movements during repetitive movement tasks such as walking. Mobile EEG technology now allows us to examine how this happens during gait. 18 participants equipped with foot accelerometers and mobile EEG walked with an experimenter in three conditions: With their view of the experimenter blocked, walking naturally, and trying to synchronize their steps with the experimenter. The experimenter walked following a headphone metronome to keep their steps consistent for all conditions. Step behavior and synchronization between the experimenter and participant were compared between conditions. Additionally, event-related spectral perturbations (ERSPs) were time-warped to the gait cycle in order to analyze alpha-mu (7.5-12.5 Hz) and beta (16-32 Hz) rhythms over the whole gait cycle. Step synchronization was significantly higher in the synchrony condition than in the natural condition. Likewise regarding ERSPs, right parietal channel (C4, C6, CP4, CP6) alpha-mu and central channel (C1, Cz, C2) beta power were suppressed from baseline in the walking synchrony condition compared to the natural walking condition. The natural and blocked conditions were not found to be significantly different in behavioral or spectral comparisons. Our results are compatible with the view that intentional synchronization employs systems associated with social interaction as well as the central motor system.

23 July 2019 in Psychophysiology
Verified
Journal Article
Closed access
PDF file
JSJoanna E. M. Scanlon
Joanna E. M. Scanlon
DCDanielle L. Cormier
Danielle L. Cormier
KTKimberley A. Townsend
Kimberley A. Townsend
JKJonathan W. P. Kuziek
Jonathan W. P. Kuziek
KMKyle E. Mathewson
Kyle E. Mathewson

23 December 2022 in Data in Brief
Verified
Journal Article
Open access
JSJoanna E. M. Scanlon
Joanna E. M. Scanlon
NJNadine S.J. Jacobsen
Nadine S.J. Jacobsen
MMMarike C. Maack
Marike C. Maack
SDStefan Debener
Stefan Debener
This article describes a dataset from one standing and two outdoor walking tasks. Each task was performed by the same 18 participants twice, using foot accelerometers and two different EEG system configurations. The first task was a brief eyes open/eyes closed task. The second task was a six minute auditory oddball task performed in three conditions: Standing, walking alone and walking next to an experimenter. In the third task, the participants walked with the experimenter in three conditions: With their view of the experimenter blocked, walking naturally, and trying to synchronize their steps with the experimenter. During all walking conditions which included the experimenter, the experimenter walked following a headphone metronome to keep their steps consistent, also wearing a foot accelerometer. All tasks were performed twice on two separate days, using active electrode and passive electrode EEG configurations (Brain Products, GmbH). Data was used for Scanlon et al. (2021) and Scanlon et al. (2022), and could be used for learning about attention, walking mechanisms and social neuroscience. Scanlon, J. E., Jacobsen, N. S. J., Maack, M. C., & Debener, S. (2021). Does the electrode amplification style matter? A comparison of active and passive EEG system configurations during standing and walking. European Journal of Neuroscience, 54(12), 8381-8395. Scanlon, J. E. M., Jacobsen, N. S. J., Maack, M. C., & Debener, S. (2022). Stepping in time: Alpha-mu and beta oscillations during a walking synchronization task. NeuroImage, 253, 119099.