Anduel Kuqi

Mr. Anduel Kuqi


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2023 in International Journal of Online and Biomedical Engineering (iJOE)
Verified
Journal Article
Open access
PDF file
IEIndrit Enesi
Indrit Enesi
AKAnduel Kuqi
Anduel Kuqi
3D reconstruction of objects is with ​​interest nowadays, mainly in production industry. The main challenge of them is accuracy and processing time, especially for small and detailed objects. The field of photogrammetry realizes the 3D reconstruction of objects through 2D photos. Different software, free or non-free exists, providing different quality and performance. Accurate 3D reconstruction is important in cloning objects, especially in the industry of spare parts or in the production of prostheses in medicine, etc. Determining accurately the sizes of the object, especially those with complex geometric shapes is very important in the 3D printing process. The purpose of this paper is the analysis of the performance of 3D reconstruction in terms of accuracy for objects of different sizes regarding the number of its photos and the time evaluation of this process. The 3D reconstruction will be performed by free software Meshroom, measurement will be done in MeshLab and non-free software Agisoft. Experimental results show that quality and performance of 3D reconstruction depends on the number of photos of the object, concluding in finding the optimal balance between these parameters. By comparing obtained results from MeshRoom and Meshlag versus Agisoft, it is claimed that Agisoft performs better than MeshRoom. It offers more optimization techniques, reduces processing time, more visual quality in the reconstructed 3D object as well as more accuracy in measurement.

1 December 2022 in Journal of Engineering Research and Sciences
Verified
Journal Article
Open access
IEIndrit Enesi
Indrit Enesi
AKAnduel Kuqi
Anduel Kuqi
Analyzing the Measurement Accuracy of 3D Reconstruction for Small Objects using Different Software; A Case Study by Indrit Enesi* , Anduel Kuqi Polytechnic University of Tirana, Electronic and Telecommunication Department, Faculty of Information Technology, Tirana, 1000, Albania * Author to whom correspondence should be addressed. Journal of Engineering Research and Sciences, Volume 1, Issue 12,

9 September 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
OQOlti Qirici
Olti Qirici
EEEugen Enesi
Eugen Enesi
KBKleona Binjaku
Kleona Binjaku
AKAnduel Kuqi
Anduel Kuqi
IEIndrit Enesi
Indrit Enesi
ADArjan Durresi
Arjan Durresi
Intracranial aneurysm rupture is a major cause of hemorrhagic stroke and a significant contributor to human mortality. With the emergence of artificial intelligence (AI), particularly machine learning (ML) and deep learning (DL), a series of new approaches have been introduced to improve aneurysm detection, rupture assessment, risk prediction, and prognosis evaluation. This narrative review synthesizes the findings from 21 peer-reviewed studies identified through searches in PubMed, Scopus, Web of Science, and IEEE Xplore, covering the period from June to September 2025. The reviewed studies examined the use of AI for aneurysm detection, rupture assessment and risk prediction, and prognosis evaluation based on clinical, morphological, radiomic, and hemodynamic data. The reviewed studies applied different AI approaches, including conventional ML algorithms, convolutional neural networks, transformer-based models, radiomics, and multimodal models. Several studies reported encouraging performance in aneurysm detection, segmentation, rupture assessment, and prognosis evaluation, while some approaches showed better performance compared with traditional clinical scoring systems. However, important limitations remain, including the frequent use of small or single-center datasets, limited external validation, and heterogeneity in imaging protocols and feature-extraction methods. AI is showing strong potential in supporting the management of intracranial aneurysms. However, further research is needed, particularly through multicenter and external validation, improved model explainability and robustness, and better integration of these systems into clinical workflows.

13 May 2026 in Computers
Verified
Journal Article
Open access
PDF file
AKAmbra Korra
Ambra Korra
AKAnduel Kuqi
Anduel Kuqi
IEIndrit Enesi
Indrit Enesi
Automated defect detection in industrial casting processes is important for improving product quality while reducing the cost of manual inspection. In this work, two deep convolutional neural network (CNN) architectures, InceptionV3 and InceptionResNetV2, are evaluated for the binary classification of defects in submersible pump impellers. A genetic algorithm (GA) is used to optimize key hyperparameters, including dropout rate, learning rate, and dense layer configuration, while model complexity is assessed through Pareto-based analysis. Single-run optimization results show that InceptionV3 achieves high classification accuracy (99.0%) with lower model complexity than InceptionResNetV2 (98.75%). Repeated experiments using different random seeds demonstrate relatively stable performance across runs, with InceptionV3 achieving an accuracy of 0.9913 ± 0.003 and InceptionResNetV2 achieving 0.9860 ± 0.0076. Additional experiments were conducted using random-search baselines and classification-head ablation studies (Flatten vs. Global Average Pooling). These experiments showed that optimization strategy and architectural design choices influence both predictive performance and computational complexity. The environmental impact of the training process is evaluated using CodeCarbon, with energy consumption ranging from 0.083 to 0.098 kWh and carbon emissions ranging from 2.008 to 2.401 g CO2eq for InceptionV3 and InceptionResNetV2, respectively. Overall, the results suggest that the most effective configuration depends on the evaluated architecture and experimental setting, highlighting the importance of balancing accuracy, model complexity, and computational efficiency in industrial defect detection systems.

4 November 2026 in Computers
Verified
Journal Article
Open access
PDF file
AKAnduel Kuqi
Anduel Kuqi
AKAmbra Korra
Ambra Korra
IEIndrit Enesi
Indrit Enesi
For structure-from-motion (SfM), an important step is provided through camera intrinsics, especially when camera metadata are not available. Although subsequent SfM optimization and bundle adjustment (BA) refine the camera parameters using multi-view observations, it remains unclear whether differences in the initial intrinsics have a lasting effect on the optimization process and, ultimately, on the quality of the reconstructed scene. This study investigates the role of camera intrinsic initialization in an end-to-end AliceVision/Meshroom SfM and multi-view stereo (MVS) pipeline, with particular focus on whether similar optimized intrinsics necessarily lead to similar final reconstructions. Here, three initialization strategies are evaluated within an AliceVision/Meshroom pipeline: camera intrinsics obtained from image metadata, AliceVision’s 45° field-of-view fallback, and single-image calibration using a pretrained GeoCalib model. GeoCalib is integrated only at the camera-initialization stage, where its predicted intrinsics are written into the AliceVision SfMData structure. All subsequent stages of the reconstruction pipeline remain unchanged, including feature extraction, image matching, feature matching, SfM, bundle adjustment, dense reconstruction, meshing, and texturing. Experiments are conducted on the 41-image Monstree smartphone collection and the 27-image ETH3D Observatory sequence. ETH3D additionally provides reference camera calibration and sparse reconstruction data, allowing the effect of initialization to be measured against ground truth. Here, the evaluation is extended to selected six-view, eight-view, and twelve-view Observatory subsets, the 26-view Boulders scene, and paired dense reconstructions of the 23-view ETH3D Terrace training scene. The experiments show that the three methods can produce considerably different initial camera parameters while still converging to similar optimized focal length. For the evaluated datasets, this suggests that the final intrinsic parameters are strongly influenced by multi-view optimization rather than by the initialization alone. The experiments also show that more accurate single-image calibration does not necessarily result in a correspondingly different or improved optimized focal length. However, similarity in the final intrinsic parameters does not, by itself, demonstrate that the resulting dense reconstructions are equivalent. The six-view and Boulders comparisons show that the convergence observed on the full Observatory sequence does not extend to every tested configuration. Terrace achieves F1-scores of 0.8273 for fallback and 0.8261 for learned initialization at 2 cm against public laser scans. These findings highlight the need to distinguish between the quality of the initial camera calibration, the recovery of camera parameters during SfM optimization, and the quality of the final dense reconstruction. These findings remain limited to the selected subsets and tested scenes.