The application of fractional calculus in power electronics modeling provides an innovative method for improving inverter performance. This paper presents a three-phase inverter topology with fractional-order LC filter characteristics, analyzes its frequency response, and develops mathematical models in both stationary and rotating reference frames. Based on these models, a dual closed-loop decoupling control strategy for voltage and current is designed to enhance system stability and dynamic performance. In the power control loop, fractional-order virtual synchronous generator control (FOVSG) is employed. Observations show that increasing the fractional-order of the rotor leads to a higher transient frequency variation rate. To address this, an adaptive rotational inertia control scheme is integrated into the FOVSG structure (ADJ-FOVSG), enabling real-time adjustment of inertia to suppress transient frequency fluctuations. Experimental results demonstrate that when the reference active power changes, ADJ-FOVSG effectively suppresses power overshoot. Compared to traditional VSG, ADJ-FOVSG reduces the power regulation time by approximately 34.5% and decreases the peak frequency deviation by approximately 37.2%. Compared to the adaptive rotational inertia control in traditional VSG, ADJ-FOVSG improves regulation time by about 24% and reduces peak frequency deviation by roughly 24.4%.
A large number of practical systems show pronounced fractional-order features. In comparison with integer-order calculus, fractional-order calculus has been demonstrated to possess enhanced precision in the description of the dynamic behavior of complex systems. The increase in control accuracy and flexibility results from this improvement. This study explores a direct-drive wind power generation system featuring permanent magnets, which incorporates fractional-order direct current bus (DC-bus) capacitor and fractional-order inductor–capacitor–inductor (FOLCL) grid-connected filter. For the machine-side rectifier, a fractional-order sliding mode (FOSM) speed outer-loop control and a fractional-order proportional–integral (FOPI) current inner-loop control were designed. A voltage outer-loop control using FOSM and a current inner-loop control using FOPI were developed for the grid-side inverter. Through simulation analyses under various wind speeds and grid fault conditions, it is demonstrated that compared to a control strategy using FOPI controllers in both inner and outer loops, the proposed control scheme which employs a FOSM outer-loop and reduces the overshoot of DC-bus voltage and grid-connected current by 21.51% and 32.49%, respectively, under sudden wind speed changes. Furthermore, during grid voltage sag faults, the maximum drop in DC-bus voltage and grid-connected active power are reduced by 65.38% and 33.38%, respectively. These results highlight the proposed method’s superior dynamic and static performance, as well as enhanced resistance to disturbances.
24 October 2026 in Electric Power Systems Research
The existing basic control system of fractional-order modular multilevel converters (FO-MMCs) is mainly designed for ideal operating conditions and exhibits limited adaptability under grid unbalanced conditions. To address this issue, this paper proposes a fractional-order composite control system for a FO-MMC. The proposed system consists of fractional-order positive-sequence and negative-sequence control loops. The positive-sequence control loop includes a power outer-loop fractional-order proportional-integral (FOPI) controller and a fractional-order decoupled FOPI positive-sequence current inner-loop controller. The negative-sequence control loop adopts a fractional-order decoupled FOPI negative-sequence current inner-loop controller. Combined with three sequence current reference calculation strategies, the proposed system achieves three control objectives: active power oscillation elimination (APOE), reactive power oscillation elimination (RPOE), and balanced positive-sequence current output (BPSC). A FO-MMC simulation model was established based on the MATLAB/Simulink platform, and the proposed control system was verified. The results demonstrate that the proposed control system achieves accurate regulation of positive- and negative-sequence currents. Under different control objectives, the system exhibits excellent dynamic response and steady-state performance, providing a theoretical basis for stable FO-MMC operation under unbalanced grid conditions.
Conventional integer-order parameter designs of grid-forming inverters provide limited degrees of freedom for impedance adjustment, motivating the exploration of additional approaches for flexible impedance reshaping across different frequency ranges. This paper establishes a full fractional-order grid-forming inverter (FFO-GFMI) by incorporating fractional-order inductor-capacitor (LC) filters, corresponding decoupling control, and fractional-order multi-loop controllers into a conventional grid-forming inverter. Based on the harmonic linearization method, positive- and negative-sequence impedance models of the FFO-GFMI are developed to characterize its broadband impedance characteristics. The developed models are validated through impedance scanning, and the effects of fractional-order parameters on broadband impedance characteristics are systematically investigated. The results reveal that fractional-order LC filters mainly regulate medium- and high-frequency resonance characteristics, while fractional-order control loops provide effective low- and medium-frequency impedance reshaping. Furthermore, load-step simulations demonstrate that the selected fractional-order configuration improves dynamic performance, reducing the active power settling time from 0.3121 s to 0.1974 s and the active power overshoot from 19.75% to 4.51%.