Esperanza González-Rojano

Dr. Esperanza González-Rojano


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
Victor Mangas-SanjuanVictor Mangas-Sanjuan
Victor Mangas-Sanjuan
MSMarta Simón
Marta Simón
EGEsperanza González-Rojano
Esperanza González-Rojano
DODolores Ochoa
Dolores Ochoa
Francisco Abad-SantosFrancisco Abad-Santos
Francisco Abad-Santos
AGAlfredo García-Arieta
Alfredo García-Arieta
(1) Background: this article investigates which PK metrics in a single-dose study (concentration at the end of posology interval, Cτ, partial areas under the curve, pAUCs, or half-value duration, HVD) are more sensitive and less variable for predicting the failure of a prolonged-release product at steady-state that was the bioequivalent for Cmax, AUC0-t and AUC0-inf, in the single-dose study; (2) Methods: a cross-over study was performed in 36 subjects receiving desvenlafaxine 100 mg prolonged-release tablets. Conventional (Cmax, AUC0-t and AUC0-inf) and additional (Cτ, pAUCs and HVD) PK metrics were considered after single-dose conditions. Predicted PK metrics at steady state (AUC0-τ, Cmax,ss, and Cτ,ss) were derived using a population PK model approach; (3) Results: the existing differences in the shape of the concentration–time curves precluded to show equivalence for Cτ,ss in the simulated study at steady state. This failure to show equivalence at steady state was predicted by Cτ, pAUCs and HVD in the single-dose study. Cτ was the most sensitive metric for detecting the different shape, with a lower intra-subject variability than HVD; (4) Conclusions: conventional PK metrics for single-dose studies (Cmax, AUC0-t and AUC0-inf) are not enough to guarantee bioequivalence at steady state for prolonged-release products.

5 April 2020 in IBJ Clinical Pharmacology
Verified
Journal Article
Open access
PDF file
EGEsperanza González-Rojano
Esperanza González-Rojano
JMJ. Marcotegui
J. Marcotegui
Utility of a computer tool for detection of potentially inappropriate medications in older patients in a tertiary hospital.

10 August 2026 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
PPPaulo Paixão
Paulo Paixão
EGEsperanza González-Rojano
Esperanza González-Rojano
DODolores Ochoa
Dolores Ochoa
Francisco Abad-SantosFrancisco Abad-Santos
Francisco Abad-Santos
MRManuel Román
Manuel Román
AGAlfredo García-Arieta
Alfredo García-Arieta
Background: In those products where onset of action is clinically relevant, different metrics have been proposed to demonstrate bioequivalence, and different metrics, statistical methods and acceptance criteria have been employed in the United States, the European Union and Canada in the past. Recently, a harmonised approach has been recommended by the ICH M13A guideline. Methods: This work investigates the outcomes of several metrics in studies conducted in the Clinical Trials Unit of Hospital Universitario de La Princesa, Madrid, Spain, from 2000 to 2016, to identify the most adequate metric to reflect the onset of action. Results: An optimal single metric cannot be identified in these studies. The metrics show very high variability in most cases, making the conclusion of bioequivalence very unlikely with the usual sample sizes required for demonstration of bioequivalence based on Cmax and AUC. This is particularly evident if 90% confidence intervals are required to aim at inference of the study results to the whole population. Optimisation of the sampling times around tmax may be needed to reduce variability and increase reliability of the estimations. Conclusions: pAUC and tmax have been considered acceptable metrics under the ICH M13A guideline. For tmax, a non-parametric 90% confidence interval of the difference between the two formulations within a widened acceptance range may be sufficient for concluding BE in the early onset of action. Regarding pAUC, its high intra-subject variability can be addressed with the current scaling.