Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, causing morbidity and mortality in millions worldwide. The atria of patients with persistent AF (PsAF) are characterized by the presence of extensive and distributed atrial fibrosis, which facilitates the formation of persistent reentrant drivers (RDs, i.e., spiral waves), which promote fibrillatory activity. Targeted catheter ablation of RD-harboring tissues has shown promise as a clinical treatment for PsAF, but the outcomes remain sub-par. Personalized computational modeling has been proposed as a means of non-invasively predicting optimal ablation targets in individual PsAF patients, but it remains unclear how RD localization dynamics are influenced by inter-patient variability in the spatial distribution of atrial fibrosis, action potential duration (APD), and conduction velocity (CV). Here, we conduct simulations in computational models of fibrotic atria derived from the clinical imaging of PsAF patients to characterize the sensitivity of RD locations to these three factors. We show that RDs consistently anchor to boundaries between fibrotic and non-fibrotic tissues, as delineated by late gadolinium-enhanced magnetic resonance imaging, but those changes in APD/CV can enhance or attenuate the likelihood that an RD will anchor to a specific site. These findings show that the level of uncertainty present in patient-specific atrial models reconstructed without any invasive measurements (i.e., incorporating each individual's unique distribution of fibrotic tissue from medical imaging alongside an average representation of AF-remodeled electrophysiology) is sufficiently high that a personalized ablation strategy based on targeting simulation-predicted RD trajectories alone may not produce the desired result.
Identification of optimal ablation sites in hearts with infarct-related ventricular tachycardia (VT) remains difficult to achieve with the current catheter-based mapping techniques. Limitations arise from the ambiguities in determining the reentrant pathways location(s). The goal of this study was to develop experimentally validated, individualized computer models of infarcted swine hearts, reconstructed from high-resolution ex-vivo MRI and to examine the accuracy of the reentrant circuit location prediction when models of the same hearts are instead reconstructed from low clinical-resolution MRI scans. To achieve this goal, we utilized retrospective data obtained from four pigs ~10 weeks post infarction that underwent VT induction via programmed stimulation and epicardial activation mapping via a multielectrode epicardial sock. After the experiment, high-resolution ex-vivo MRI with late gadolinium enhancement was acquired. The Hi-res images were downsampled into two lower resolutions (Med-res and Low-res) in order to replicate image quality obtainable in the clinic. The images were segmented and models were reconstructed from the three image stacks for each pig heart. VT induction similar to what was performed in the experiment was simulated. Results of the reconstructions showed that the geometry of the ventricles including the infarct could be accurately obtained from Med-res and Low-res images. Simulation results demonstrated that induced VTs in the Med-res and Low-res models were located close to those in Hi-res models. Importantly, all models, regardless of image resolution, accurately predicted the VT morphology and circuit location induced in the experiment. These results demonstrate that MRI-based computer models of hearts with ischemic cardiomyopathy could provide a unique opportunity to predict and analyze VT resulting for from specific infarct architecture, and thus may assist in clinical decisions to identify and ablate the reentrant circuit(s).
To predict arrhythmia susceptibility in myocardial infarction (MI) patients with left ventricular ejection fraction (LVEF) >35% using a personalized virtual heart simulation approach. A total of four contrast enhanced magnetic resonance imaging (MRI) datasets of patient hearts with MI and average LVEF of 44.0 ± 2.6% were used in this study. Because of the preserved LVEF, the patients were not indicated for implantable cardioverter defibrillator (ICD) insertion. One patient had spontaneous ventricular tachycardia (VT) prior to the MRI scan; the others had no arrhythmic events. Simulations of arrhythmia susceptibility were blind to clinical outcome. Models were constructed from patient MRI images segmented to identify myocardium, grey zone, and scar based on pixel intensity. Grey zone was modelled as having altered electrophysiology. Programmed electrical stimulation (PES) was performed to assess VT inducibility from 19 bi-ventricular sites in each heart model. Simulations successfully predicted arrhythmia risk in all four patients. For the patient with arrhythmic event, in-silico PES resulted in VT induction. Simulations correctly predicted that VT was non-inducible for the three patients with no recorded VT events. Results demonstrate that the personalized virtual heart simulation approach may provide a novel risk stratification modality to non-invasively and effectively identify patients with LVEF >35% who could benefit from ICD implantation.
1 January 2022 in Mathematical Biosciences and Engineering
Personalized heart models are widely used to study the mechanisms of cardiac arrhythmias and have been used to guide clinical ablation of different types of arrhythmias in recent years. MRI images are now mostly used for model building. In cardiac modeling studies, the degree of segmentation of the heart image determines the success of subsequent 3D reconstructions. Therefore, a fully automated segmentation is needed. In this paper, we combine U-Net and Transformer as an alternative approach to perform powerful and fully automated segmentation of medical images. On the one hand, we use convolutional neural networks for feature extraction and spatial encoding of inputs to fully exploit the advantages of convolution in detail grasping; on the other hand, we use Transformer to add remote dependencies to high-level features and model features at different scales to fully exploit the advantages of Transformer. The results show that, the average dice coefficients for ACDC and Synapse datasets are 91.72 and 85.46%, respectively, and compared with Swin-Unet, the segmentation accuracy are improved by 1.72% for ACDC dataset and 6.33% for Synapse dataset.
1 January 2012 in Computational and Mathematical Methods in Medicine
Many heart anatomy models have been developed to study the electrophysiological properties of the human heart. However, none of them includes the geometry of the whole human heart. In this study, an anatomically detailed mathematical model of the human heart was firstly reconstructed from the computed tomography images. In the reconstructed model, the atria consisted of atrial muscles, sinoatrial node, crista terminalis, pectinate muscles, Bachmann’s bundle, intercaval bundles, and limbus of the fossa ovalis. The atrioventricular junction included the atrioventricular node and atrioventricular ring, and the ventricles had ventricular muscles, His bundle, bundle branches, and Purkinje network. The epicardial and endocardial myofiber orientations of the ventricles and one layer of atrial myofiber orientation were then measured. They were calculated using linear interpolation technique and minimum distance algorithm, respectively. To the best of our knowledge, this is the first anatomically-detailed human heart model with corresponding experimentally measured fibers orientation. In addition, the whole heart excitation propagation was simulated using a monodomain model. The simulated normal activation sequence agreed well with the published experimental findings.
11 October 2024 in Reviews in Cardiovascular Medicine
Cardiac conduction velocity (CV) is a critical electrophysiological characteristic of the myocardium, representing the speed at which electrical pulses propagate through cardiac tissue. It can be delineated into longitudinal, transverse, and normal components in the myocardium. The CV and its anisotropy ratio are crucial to both normal electrical conduction and myocardial contraction, as well as pathological conditions where it increases the risk of conduction block and reentry. This comprehensive review synthesizes longitudinal and transverse CV values from clinical and experimental studies of human infarct hearts, including findings from the isthmus and outer loop, alongside data derived from animal models. Additionally, we explore the anisotropic ratio of conductivities assessed through both animal and computational models. The review culminates with a synthesis of scientific evidence that guides the selection of CV and its corresponding conductivity in cardiac modeling, particularly emphasizing its application in patient-specific cardiac arrhythmia modeling.