Kwang Kyoun Kim

Prof. Dr. Kwang Kyoun Kim

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2023 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
KKKwang Kyoun Kim
Kwang Kyoun Kim
SKSeungcheol Kwon
Seungcheol Kwon
JKJunhyuk Kwon
Junhyuk Kwon
JHJihyo Hwang
Jihyo Hwang

16 March 2024 in Osteoporosis and Sarcopenia
Verified
Journal Article
Open access
TTTa-Wei Tai
Ta-Wei Tai
HCHsuan-Yu Chen
Hsuan-Yu Chen
CSChien-An Shih
Chien-An Shih
CHChun-Feng Huang
Chun-Feng Huang
EMEugene McCloskey
Eugene McCloskey
CWChih-Hsing Wu
Chih-Hsing Wu
This study aimed to present the Asia-Pacific consensus on long-term and sequential therapy for osteoporosis, offering evidence-based recommendations for the effective management of this chronic condition. The primary focus is on achieving optimal fracture prevention through a comprehensive, individualized approach. A panel of experts convened to develop consensus statements by synthesizing the current literature and leveraging clinical expertise. The review encompassed long-term anti-osteoporosis medication goals, first-line treatments for individuals at very high fracture risk, and the strategic integration of anabolic and antiresorptive agents in sequential therapy approaches. The panelists reached a consensus on 12 statements. Key recommendations included advocating for anabolic agents as the first-line treatment for individuals at very high fracture risk and transitioning to antiresorptive agents following the completion of anabolic therapy. Anabolic therapy remains an option for individuals experiencing new fractures or persistent high fracture risk despite antiresorptive treatment. In cases of inadequate response, the consensus recommended considering a switch to more potent medications. The consensus also addressed the management of medication-related complications, proposing alternatives instead of discontinuation of treatment. This consensus provides a comprehensive, cost-effective strategy for fracture prevention with an emphasis on shared decision-making and the incorporation of country-specific case management systems, such as fracture liaison services. It serves as a valuable guide for healthcare professionals in the Asia-Pacific region, contributing to the ongoing evolution of osteoporosis management.

1 March 2019 in Knee Surgery & Related Research
Verified
Journal Article
Open access
PDF file
KKKwang Kyoun Kim
Kwang Kyoun Kim
JKJungsung Kim
Jungsung Kim
DLDo Kyung Lee
Do Kyung Lee
SLSohui Lim
Sohui Lim
JEJiyoon Eom
Jiyoon Eom
Kwangkyoun Kim, MD, Jungsung Kim, PhD, Dokyoung Lee, MD, Sohui Lim, and Jiyoon Eom. Knee Surg Relat Res 2019;31:19-24. https://doi.org/10.5792/ksrr.18.038

1 January 2020 in Yonsei Medical Journal
Verified
Journal Article
Open access
KKKwang Kyoun Kim
Kwang Kyoun Kim
Stephen HowellStephen Howell
Stephen Howell
YWYe-Yeon Won
Ye-Yeon Won
Kinematically aligned total knee arthroplasty (TKA) is a new alignment technique. Kinematic alignment corrects arthritic deformity to the patient's constitutional alignment in order to position the femoral and tibial components, as well as to restore the knee's natural tibial-femoral articular surface, alignment, and natural laxity. Kinematic knee motion moves around a single flexion-extension axis of the distal femur, passing through the center of cylindrically shaped posterior femoral condyles. Since it can be difficult to locate cylindrical axis with conventional instrument, patient-specific instrument (PSI) is used to align the kinematic axes. PSI was recently introduced as a new technology with the goal of improving the accuracy of operative technique, avoiding practical issues related to the complexity of navigation and robotic system, such as the costs and higher number of personnel required. There are several limitations to implement the kinematically aligned TKA with the implant for mechanical alignment. Therefore, it is important to design an implant with the optimal shape for restoring natural knee kinematics that might improve patient-reported satisfaction and function.

25 March 2022 in Osteoporosis and Sarcopenia
Verified
Journal Article
Open access
KKKwang Kyoun Kim
Kwang Kyoun Kim
SLSoek-Won Lee
Soek-Won Lee
JCJae Kyu Choi
Jae Kyu Choi
YWYe-Yeon Won
Ye-Yeon Won
This study aims to analyze the changes in epidemiology and the postoperative outcomes in patients with hip fractures during the COVID-19 pandemic compared to non-pandemic period. According to the date of declaration of “mandatory social distance”, we separated patients into 2 groups over a 1-year period: Period A and period B. We assessed the overall time to surgery, delay in surgery (> 24 hours, > 36 hours, and > 48 hours), reason of delay, length of hospital stay, type of surgery, and postoperative complications. The number of operated hip fractures and other trauma decreased in period B compared with period A by 17%, and 23%, respectively. The number of patients with delay in surgery by > 24 hours and > 36 hours was significantly higher in period B compared to that in period A (P = 0.035, P = 0.012, respectively). However, no significant difference in the number of delay in surgery > 48 hours and mean overall time to surgery between the 2 groups was observed (P = 0.856, P = 0.399, respectively). There was no difference in the duration of hospital stay, type of surgery, and postoperative complications between periods A and B. During the COVID-19 pandemic, the decrease in hip fractures was relatively fewer compared to the decrease in orthopedic trauma. Although hip fracture surgeries were delayed for over 24 hours and 36 hours, there was no increase in delay for over 48 hours and postoperative complications.

15 July 2020 in Journal of Pathology and Translational Medicine
Verified
Journal Article
Open access
PDF file
KKKwang Kyoun Kim
Kwang Kyoun Kim
YPYoung-Wook Park
Young-Wook Park
TKTae-Hyeong Kim
Tae-Hyeong Kim
KSKyung-Deok Seo
Kyung-Deok Seo
Of the drugs developed to prevent and treat osteoporosis, bisphosphonate has played a very important role in preventing osteoporotic fractures. However, case reports describing atypical femoral fractures in patients using long-term bisphosphonates have emerged. The majority of atypical femur fractures occurs in the lateral aspect of the subtrochanteric or femur diaphysis, which is explained by accumulation of tensile stress in these areas. Although the superior cortex of the femur neck withstands maximum tensile stress, to our knowledge, there have been only two reports (three cases) of atypical femoral neck fracture. In addition, none of those case reports revealed detailed pathology related to suppressed bone turnover rate. We encountered an incomplete femoral neck fracture and diagnosed it as "atypical" on the basis of the patient's lack of trauma and medication history and pathological findings. For patients with groin pain, minimal or no trauma, and a history of long-term bisphosphonate use, an atypical femoral neck fracture should be considered.