We report a precise measurement of the parity-violating (PV) asymmetry in the elastic scattering of longitudinally polarized electrons from . We measure parts per billion, leading to an extraction of the neutral weak form factor and the charge minus the weak form factor . The resulting neutron skin thickness is relatively thin yet consistent with many model calculations. The combined CREX and PREX results will have implications for future energy density functional calculations and on the density dependence of the symmetry energy of nuclear matter.
The spin-exchange rates due to binary collisions and due to the formation of van der Waals molecules between nuclei and optically pumped rubidium-metal vapor have been determined using a technique that relies on the simultaneous observation of frequency shifts of nuclear magnetic resonance lines of noble-gas atoms and corresponding frequency shifts of electron paramagnetic resonance lines of alkali-metal atoms. In contrast, earlier studies have relied on the observation of the spin-relaxation rate of either the alkali-metal atoms or the noble-gas atoms.
Xenon polarization Transfer Contrast (XTC) MRI pulse sequences permit the gas exchange of hyperpolarized xenon-129 in the lung to be measured quantitatively. However, the pulse sequence parameter values employed in previously published work were determined empirically without considering the now-known gas exchange rates and the underlying lung physiology. By using a theoretical model for the consumption of magnetization during data acquisition, the noise intensity in the computed gas-phase depolarization maps was minimized as a function of the gas-phase depolarization rate. With such optimization the theoretical model predicted an up to threefold improvement in precision. Experiments in rabbits demonstrated that for typical imaging parameter values the optimized XTC pulse sequence yielded a median noise intensity of only about 3% in the depolarization maps. Consequently, the reliable detection of variations in the average alveolar wall thickness of as little as 300 nm can be expected. This improvement in the precision of the XTC MRI technique should lead to a substantial increase in its sensitivity for detecting pathological changes in lung function. Magn Reson Med 57:1099–1109, 2007.
29 October 2007 in IEEE Transactions on Medical Imaging
We demonstrate a method for simulating restricted diffusion of hyperpolarized gases in lung airspaces that does not rely on an idealized analytic model of alveolar structure. Instead, the restricting geometry was generated from digital representations of histological sections of actual lung tissue obtained from a rabbit model of emphysema. Monte-Carlo simulations of restricted diffusion were performed in the short-time-scale regime, for which the time-dependent diffusivity is quantitatively related to the surface-to-volume ratio (S/V) of the pore space. In each of the eight samples studied, the S/V extracted from the simulated time-dependent diffusivity curves differed by less than 3% from direct assessment of S/V using image-processing methods. Simulated MRI measurements of apparent diffusion coefficients (ADCs) were performed in three representative lung sections to determine the effect of realistic gradient pulse shapes on the extracted S/V values. It was confirmed that ADCs measured at short diffusion times using either narrow or square gradient pulses yield accurate S/V values based on previously derived theoretical relationships. Simulations of triangular and sinusoidal diffusion-sensitizing gradients were then used to quantify the modifications required to extract accurate S/V values from ADC measurements obtained using more realistic gradient waveforms.
Background: Deformable image registration (DIR)‐based lung ventilation mapping is attractive due to its simplicity, and also challenging due to its susceptibility to errors and uncertainties. In this study, we explored the use of 3D Hyperpolarized (HP) gas tagging MRI to evaluate DIR‐based lung ventilation.Method and Material: Three healthy volunteers included in this study underwent both 3D HP gas tagging MRI (t‐MRI) and 3D proton MRI (p‐MRI) using balanced steady‐state free precession pulse sequence at end of inhalation and end of exhalation. We first obtained the reference displacement vector fields (DVFs) from the t‐MRIs by tracking the motion of each tagging grid between the exhalation and the inhalation phases. Then, we determined DIR‐based DVFs from the p‐MRIs by registering the images at the two phases with two commercial DIR algorithms. Lung ventilations were calculated from both the reference DVFs and the DIR‐based DVFs using the Jacobian method and then compared using cross correlation and mutual information.Results: The DIR‐based lung ventilations calculated using p‐MRI varied considerably from the reference lung ventilations based on t‐MRI among all three subjects. The lung ventilations generated using Velocity AI were preferable for the better spatial homogeneity and accuracy compared to the ones using MIM, with higher average cross correlation (0.328 vs 0.262) and larger average mutual information (0.528 vs 0.323).Conclusion: We demonstrated that different DIR algorithms resulted in different lung ventilation maps due to underlining differences in the DVFs. HP gas tagging MRI provides a unique platform for evaluating DIR‐based lung ventilation.