ZICHAO ZHU

Mr. ZICHAO ZHU

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2024 in Measurement
Verified
Journal Article
Closed access
ZZZICHAO ZHU
ZICHAO ZHU
ZDZhe Dong
Zhe Dong
KTKai Tang
Kai Tang
JLJia Li
Jia Li
YLYingzheng Liu
Yingzheng Liu
DPDi Peng
Di Peng

15 January 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
ZZZICHAO ZHU
ZICHAO ZHU
YLYingzheng Liu
Yingzheng Liu
DPDi Peng
Di Peng
Pressure-Sensitive Paint (PSP) measurements in geometrically complex aerodynamic configurations are susceptible to systematic errors induced by surface reflections of photoluminescence, particularly near corner regions. While prior studies have acknowledged such artifacts, rigorous quantification remains challenging due to limitations in existing simulation tools and experimental methodologies. To address this gap, this study developed a novel luminescence ray-tracing (LRT) model that simulates excitation and emission light propagation based on the optical properties of PSP-coated surfaces. The LRT model was validated through benchmark experiments, demonstrating intensity simulation deviations below 6.74% within regions of interest. Using this model, we quantitatively assessed corner reflection effects on one surface (S1) across corner angles ranging from 60° to 120°, considering varying pressure magnitudes (60-140 kPa) and applied locations on the adjacent surface (S2). Generally, the reflectioninduced error on S1 follows a non-monotonic dependence on distance from the corner. Pressure changes on S2 below the reference level induce greater errors than pressure changes of equivalent magnitude above the reference level. As for the corner angle effect, when the location of pressure change is near the corner (location A on S2), the peak relative error (PRE) on S1 decreases monotonically with increasing corner angle up to 110°. However, when the pressure changes move away from the corner (location B and C on S2), the PRE remains constant for acute angles, due to similar corner angle dependency of overall PSP signal and reflection-induced error. These findings provide a valuable reference for improving PSP measurement accuracy on models with multi-face geometry.

2 September 2026 in Materials
Verified
Journal Article
Open access
PDF file
FGFeng Gu
Feng Gu
MXMingkai Xue
Mingkai Xue
ZZZICHAO ZHU
ZICHAO ZHU
YLYingzheng Liu
Yingzheng Liu
DPDi Peng
Di Peng
Photodegradation limits the accuracy of fast pressure-sensitive paints (PSPs), but its dependences on irradiance and operating conditions remain insufficiently researched. Here, the photodegradation kinetics of a polymer–ceramic PSP (PC-PSP) and a mesoporous-particle PSP (MP-PSP) were investigated under independently varied irradiance (50–122 mW/cm2), pressure (0.5–100 kPa), and temperature (20–100 °C). Normalized intensity histories acquired during 900 s of continuous irradiation were fitted with a bi-exponential model, whose composite degradation rate was correlated to the studied parameters using physical relations. PC-PSP exhibited greater absolute degradation and an approximately linear irradiance dependence (m = 1.28), whereas MP-PSP showed a nonlinear dependence (m = 2.13), consistent with a greater relative contribution from photooxidative processes. The degradation rate of PC-PSP decreased predominantly with increasing pressure because oxygen quenching reduced the excited-state luminophore population. MP-PSP exhibited a non-monotonic pressure dependence: decreasing pressure initially accelerated degradation by weakening oxygen quenching, whereas further pressure reduction below the half-saturation region suppressed oxygen-limited photooxidation. Increasing temperature generally accelerated degradation in both formulations; the fitted apparent activation energies were 12.99 kJ mol−1 for PC-PSP and 33.12 kJ mol−1 for MP-PSP, reflecticng the stronger overall temperature dependence of MP-PSP. These findings provide a basis for quantitatively evaluating PSP photostability and assessing photodegradation-induced measurement errors.