GIOVANNI TROISE

Dr. GIOVANNI TROISE

orcid

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2006 in Circulation
Verified
Journal Article
Closed access
GTGiordano Tasca
Giordano Tasca
ZMZen Mhagna
Zen Mhagna
SPSilvano Perotti
Silvano Perotti
PCPietro Berra Centurini
Pietro Berra Centurini
TSTony Sabatini
Tony Sabatini
PPPhilippe Pibarot
Philippe Pibarot
Background— Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of the prosthesis being implanted is too small in relation to body size, thus causing abnormally high transvalvular pressure gradients. The objective of this study was to examine the midterm impact of PPM on overall mortality and cardiac events after aortic valve replacement in patients with pure aortic stenosis. Methods and Results— The indexed EOA (EOAi) was estimated for each type and size of prosthesis being implanted in 315 consecutive patients with pure aortic stenosis. PPM was defined as an EOAi ≤0.80 cm 2 /m 2 and was correlated with overall mortality and cardiac events. PPM was present in 47% of patients. The 5-year overall survival and cardiac event-free survival were 82±3% and 75±4%, respectively, in patients with PPM compared with 93±3% and 87±4% in patients with no PPM ( P ≤0.01). In multivariate analysis, PPM was associated with a 4.2-fold (95% CI, 1.6 to 11.3) increase in the risk of overall mortality and 3.2-fold (95% CI, 1.5 to 6.8) increase in the risk of cardiac events. The other independent risk factors were history of heart failure, NHYA class III-IV, severe left ventricular hypertrophy, and absence of normal sinus rhythm before operation. Conclusions— PPM is an independent predictor of cardiac events and midterm mortality in patients with pure aortic stenosis undergoing aortic valve replacement. As opposed to other risk factors, PPM may be avoided or its severity may be reduced with the use of a preventive strategy at the time of operation.

1 February 2005 in The Annals of Thoracic Surgery
Verified
Journal Article
Closed access
GTGiordano Tasca
Giordano Tasca
FBFederico Brunelli
Federico Brunelli
MCMarco Cirillo
Marco Cirillo
MDMargherita DallaTomba
Margherita DallaTomba
ZMZen Mhagna
Zen Mhagna
EQEugenio Quaini
Eugenio Quaini

29 October 2015 in European Journal of Cardio-Thoracic Surgery
Verified
Journal Article
Closed access
PDF file
BGBorut Gersak
Borut Gersak
TFTheodor Fischlein
Theodor Fischlein
TFThierry A. Folliguet
Thierry A. Folliguet
BMBart Meuris
Bart Meuris
KTKevin H.T. Teoh
Kevin H.T. Teoh
MGMattia Glauber
Mattia Glauber
OBJECTIVES After a panel process, recommendations on the use of sutureless and rapid deployment valves in aortic valve replacement were given with special respect as an alternative to stented valves. METHODS Thirty-one international experts in both sutureless, rapid deployment valves and stented bioprostheses constituted the panel. After a thorough literature review, evidence-based recommendations were rated in a three-step modified Delphi approach by the experts. RESULTS Literature research could identify 67 clinical trials, 4 guidelines and 10 systematic reviews for detailed text analysis to obtain a total of 28 recommendations. After rating by the experts, 12 recommendations were identified and degree of consensus for each was determined. Proctoring and education are necessary for the introduction of sutureless valves on an institutional basis as well as for the individual training of surgeons. Sutureless and rapid deployment should be considered as the valve prosthesis of first choice for isolated procedures in patients with comorbidities, old age, delicate aortic wall conditions such as calcified root, porcelain aorta or prior implantation of aortic homograft and stentless valves as well as for concomitant procedures and small aortic roots to reduce cross-clamp time. Intraoperative transoesophageal echocardiography is highly recommended, and in case of right anterior thoracotomy, preoperative computer tomography is strongly recommended. Suitable annular sizes are 19–27 mm. There is a contraindication for bicuspid valves only for Type 0 and for annular abscess or destruction due to infective endocarditis. Careful but complete decalcification of the aortic root is recommended to avoid paravalvular leakage; extensive decalcification should be avoided not to create annular defects. Proximal anastomoses of concomitant coronary artery bypass grafting should be placed during a single aortic cross-clamp period or alternatively with careful side clamping. Available evidence suggests that the use of sutureless and rapid deployment valve is associated with (can translate into) reduced early complications such as prolonged ventilation, blood transfusion, atrial fibrillation, pleural effusions and renal replacement therapy, respectively, and may result in reduced intensive care unit and hospital stay in comparison with traditional valves. CONCLUSION The international experts recommend various benefits of sutureless and rapid deployment technology, which may represent a helpful tool in aortic valve replacement for patients requiring a biological valve. However, further evidence will be needed to reaffirm the benefit of sutureless and rapid deployment valves.

1 January 2013 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
RLRoberto Lorusso
Roberto Lorusso
SGSandro Gelsomino
Sandro Gelsomino
EVEnrico Vizzardi
Enrico Vizzardi
ADAntonio D'ALoia
Antonio D'ALoia
GCGiuseppe De Cicco
Giuseppe De Cicco
ACAntonio Maria Calafiore
Antonio Maria Calafiore

1 November 2012 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
Augusto D’OnofrioAugusto D’Onofrio
Augusto D’Onofrio
AMAntonio Messina
Antonio Messina
RLRoberto Lorusso
Roberto Lorusso
OAOttavio R. Alfieri
Ottavio R. Alfieri
MFMelissa Fusari
Melissa Fusari
Giacomo GerosaGiacomo Gerosa
Giacomo Gerosa

1 August 2017 in International Journal of Cardiology
Verified
Journal Article
Closed access
Michele Di MauroMichele Di Mauro
Michele Di Mauro
GDGuglielmo Mario Actis Dato
Guglielmo Mario Actis Dato
FBFabio Barili
Fabio Barili
SGSandro Gelsomino
Sandro Gelsomino
PSPasquale Santè
Pasquale Santè
GNGiannantonio Nappi
Giannantonio Nappi