Julia Elaine Katter

Ms. Julia Elaine Katter

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JKJulia Elaine Katter
Julia Elaine Katter
JRJonathan Martinez Rivera
Jonathan Martinez Rivera
MMMeghan Matlack
Meghan Matlack
DADaniel A. Anderson
Daniel A. Anderson
ELEmily K. Leva
Emily K. Leva
HTHenry J Tannous
Henry J Tannous
Surgical mitral valve repair is the gold standard for severe primary mitral regurgitation (MR), yet when repairs fail, open reintervention carries substantial perioperative risk. Following band annuloplasty, minimally invasive options, such as transcatheter mitral valve replacement (TMVR), remain largely unexplored due to a hypothetical concern around the lack of circumferential radial support. Although transapical transcatheter mitral valve-in-band (ViB) replacement has been reported in a single human case, we report the first controlled large-animal model of ViB. A 68 kg, 20-month-old female Yucatan mini pig underwent placement of a 28 mm mitral annuloplasty band, oversized to create MR, via clamshell sternotomy under cardiopulmonary bypass; a simulated dilated left atrium enabled transcatheter access. A 23 mm Edwards SAPIEN 3 Ultra valve was deployed within the band using the Commander delivery system under fluoroscopic guidance. The valve achieved stable fixation without embolization, paravalvular leak (PVL), or left ventricular outflow tract (LVOT) obstruction with resolution of MR on echocardiography. The stable position was consistent with a contribution from the native anterior leaflet and annulus, although radial forces were not directly measured. The animal tolerated the procedure without complications. This first-in-animal study suggests the acute technical feasibility of TMVR within a mitral annuloplasty band and supports further investigation of percutaneous band modification strategies to optimize ViB outcomes.

12 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
JKJulia Elaine Katter
Julia Elaine Katter
JRJonathan Martinez Rivera
Jonathan Martinez Rivera
MMMeghan Matlack
Meghan Matlack
DADaniel Anderson
Daniel Anderson
ELEmily K. Leva
Emily K. Leva
HTHenry J Tannous
Henry J Tannous
Surgical mitral valve repair is the gold standard for severe primary mitral regurgitation (MR), yet when repairs fail, open reintervention carries substantial perioperative risk. Following band annuloplasty, minimally invasive options, such as transcatheter mitral valve replacement (TMVR), remain largely unexplored due to a hypothetical concern around the lack of circumferential radial support. We report the first transcatheter mitral valve-in-band (ViB) replacement in a large-animal model of failed mitral repair. A 68 kg, 20-month-old female Yucatan mini pig underwent placement of a 28 mm mitral annuloplasty band, oversized to create MR, via clamshell sternotomy under cardiopulmonary bypass; a simulated dilated left atrium enabled transcatheter access. A 23 mm Edwards Sapien Ultra valve was deployed within the band using the Commander delivery system under fluoroscopic guidance. The valve achieved stable fixation without embolization, paravalvular leak (PVL), or left ventricular outflow tract (LVOT) obstruction with resolution of MR on echocardiography. The native anterior leaflet and annulus contributed circumferential radial support, and the animal tolerated the procedure without complications. This first-in-animal study demonstrates the technical feasibility and acute safety of TMVR within a mitral annuloplasty band and supports further investigation of percutaneous band modification strategies to optimize ViB outcomes.