Hyo Jung Kang

Dr. Hyo Jung Kang

Department of Physical Medicine and Rehabilitation, Veterans Health Service Medical Center, Seoul, Republic of Korea
+1

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
SJSeong Jin
Seong Jin
CAChi Hwan An
Chi Hwan An
HJHo Yong Jeong
Ho Yong Jeong
WCWoohwa Choi
Woohwa Choi
SHSun-Won Hong
Sun-Won Hong
HYHea-Eun Yang
Hea-Eun Yang
Background/Objectives: This study aimed to evaluate bone mineral density (BMD) discordance and its implications in veterans with unilateral lower-limb amputation, emphasizing the need for comprehensive hip assessments. Methods: Data were collected from 84 male veterans, and BMD was measured using dual-energy X-ray absorptiometry (DXA) at the lumbar spine, intact hip, and amputated hip. Results: The T-scores for the lumbar spine, intact hip, and amputated hip were −0.27 ± 1.69, −0.25 ± 1.20, and −1.07 ± 1.33, respectively. Osteoporosis and osteopenia were present in 19% and 34.6% of patients, respectively. Osteopenia and osteoporosis were most prevalent in the hips on the amputated side (32.1% and 13.1%, respectively), followed by the lumbar spines (22.6% and 8.3%) and the hips on the intact side (17.9% and 2.4%). BMD discordance between the lumbar spine and hip was found in 47.6% of participants, while discordance between both hips was observed in 39.3%. Transfemoral amputees had significantly lower BMD at the amputated hip compared to transtibial amputees (−2.38 ± 1.72 vs. −0.87 ± 1.16, p < 0.001). Conclusions: Veterans with unilateral lower-limb amputation exhibit a high prevalence of osteoporosis and significant BMD discordance, particularly between both hips. These findings underscore the necessity for bilateral hip assessments to ensure the accurate diagnosis and effective management of osteoporosis in this population.

21 August 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
HSHoon Ki Song
Hoon Ki Song
HKHyo Jung Kang
Hyo Jung Kang
WCWoohwa Choi
Woohwa Choi
HJHoyong Jeong
Hoyong Jeong
CAChi Hwan An
Chi Hwan An
HKHyokyum Kim
Hyokyum Kim
Background/Objectives: Ultrasound-guided flexor pollicis longus (FPL) injection is limited by the muscle’s deep location and its proximity to the cephalic vein (CV) and superficial branch of the radial nerve (SBRN). We aimed to identify the wrist and forearm posture producing the largest measured corridor width and target exposure. Methods: This prospective single-center study evaluated 51 forearms from 27 healthy adult volunteers with full range of motion, using transverse ultrasound of the distal volar forearm in six standardized positions. Two corridors were measured: CV-to-SBRN (L1, Approach A) and CV-to-radial-cortex apex (L2, Approach B), with FPL exposure height (F). Results: L2 was present in all limbs and was wider with forearm supination than in neutral (supination [SUP], +2.36 mm; flexion plus supination [F+SUP], +2.05 mm; extension plus supination [E+SUP], +2.66 mm; each p < 0.001), an ~40% increase; the three supination postures did not differ. F increased across the same postures and was greatest in E+SUP (+2.32 mm), which did not differ from SUP. L1 was absent in 12–28% of limbs and, where present, was narrower with supination (both p < 0.001). Conclusions: In healthy adults, forearm supination widened the safety corridor and increased target exposure. Applicability to spasticity requires confirmation.