The purpose of this study was to compare the proximal surface contour, size of contact area, and volume difference before and after restoration in artificial teeth of primary molars during proximal composite resin restoration using different matrix systems. Four types of artificial teeth were restored with composite resin using sectional matrix systems-Palodent V3 Sectional Matrix System and myJunior Kitand a circumferential matrix system-Tofflemire Matrix System-and modeled threedimensionally for analysis. When sectional matrix systems were used, there was a higher probability of concave proximal surface contour and simultaneously greater contact area and volume. This is attributed to the dead soft properties of the matrix band used in sectional matrix systems, which can lead to deformation of the band and hence an excessive amount of resin applied around the contact point. Additionally, the rubber wedge in the sectional matrix system may not help the matrix band fit into the cavity. Therefore, based on the findings of this study, morphological aspects need to be carefully considered for proximal composite resin restoration of primary molars using sectional matrix systems.
1 January 2020 in The Journal of Korean Academy of Prosthodontics
Background/Objectives: Cone-beam computed tomography (CBCT)-to-intraoral-scan registration in edentulous implant planning relies on radiopaque fiducial markers, yet how marker design governs marker-geometry reproduction is unclear. We quantified the effects of shape, size and configuration and where the error arose. Methods: Eighteen edentulous mandibular denture designs (three shapes × three sizes, 2–4 mm × two configurations; five markers each) were printed and CBCT-imaged three times at 0.2 mm voxel. Distances, angles, a leave-one-marker-out (LOMO) error and a markerless control were analyzed at the design level (n = 18). Results: Acquisition reproducibility was voxel-limited (median 49 μm). Marker size governed trueness and precision (partial ω2p 0.25–0.65), with no shape effect detected. The LOMO error fell with size (541 to 359 μm; p = 0.004), whereas the markerless control did not (p = 0.653); the size effect differed between approaches. Twenty percent of 2 mm markers exceeded the 300 μm threshold—unstable localization, not failed detection. In the markerless control, 6 of 270 markers (2.2%) exceeded 1 mm despite acceptable global surface fits. Conclusions: A satisfactory global surface-fit residual may conceal substantial local misregistration, whereas fiducial landmarks permit independent verification of alignment. Marker size most directly governed reproduction fidelity; ≥3 mm diameters are recommended for the rotationally symmetric geometries tested.