Mehmet Akif Şahin

Dr. Mehmet Akif Şahin

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2026 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
MŞMehmet Akif Şahin
Mehmet Akif Şahin
FDFatih Durgut
Fatih Durgut
SYSeyhmus Yigit
Seyhmus Yigit
MAMehmet Sait Akar
Mehmet Sait Akar
EÖEmin Özkul
Emin Özkul
SÇSadettin Çiftçi
Sadettin Çiftçi
Background: Proximal extra-articular tibial fractures present considerable biomechanical and technical challenges due to the short proximal fragment, the wide metaphyseal canal, and the deforming forces acting around the knee. These factors predispose isolated intramedullary (IM) nailing to malalignment, prompting the use of adjunct reduction aids such as Poller screws or supplemental plates. This study aimed to compare the mechanical behavior of IM nailing alone with that augmented by Poller screws or a monocortical plate in a standardized proximal tibia fracture model. Methods: Fifteen synthetic tibiae with an AO/OTA 41-A2.3 extra-articular proximal fracture model were randomized into three groups ( n = 5 each): IM nailing alone, IM nailing plus two Poller screws, and IM nailing plus a four-hole medial monocortical plate. All specimens were instrumented with a 10 × 340-mm titanium nail and two proximal and two distal locking screws. Mechanical testing included axial compression to 800 N, axial loading to failure, and torsion at a rate of 25°/min. Displacement, stiffness, maximum load, and torque parameters were compared across groups. Results: Under 800 N axial load, the plate-augmented group showed the lowest displacement and highest stiffness (2.40 ± 0.22 mm; 332.4 ± 21.7 N/mm), followed by the Poller screw group (2.48 ± 0.25 mm; 321.6 ± 19.4 N/mm) and the IM-only group (3.45 ± 0.31 mm; 231.8 ± 18.9 N/mm) ( p < 0.001). In axial load-to-failure testing, the plate group reached the machine limit (4500 N), while the Poller screw and IM-only groups demonstrated lower capacities (4318 ± 210 N and 3906 ± 265 N, respectively; p = 0.012). Torsional stiffness was likewise highest with plate augmentation (0.30 ± 0.04 Nm/°) and lowest in the IM-only constructs ( p = 0.021). Conclusion: Both Poller screw and monocortical plate augmentation improved the initial mechanical stability of IM-nailed proximal tibial constructs, with the plate configuration yielding the highest stiffness values. However, the absolute displacement differences under physiologic axial loads were modest, and the primary clinical role of these adjuncts is reduction control rather than pure stiffness enhancement. Accordingly, the choice between Poller screws and supplemental plating should be individualized based on the fracture pattern, soft-tissue considerations, implant availability, and the surgeon’s experience.


Verified
Journal Article
Open access
PDF file
MŞMehmet Akif Şahin
Mehmet Akif Şahin
FDFatih Durgut
Fatih Durgut
KDKutbettin Dinçer
Kutbettin Dinçer
EBEmin Can Balcı
Emin Can Balcı
MUMetin Uzun
Metin Uzun
Background: Hallux valgus (HV) is a three-dimensional deformity, and preoperative assessment of sesamoid position and first metatarsal rotation is important for surgical planning. Weight-bearing computed tomography (WBCT) enables three-dimensional assessment but was unavailable at our institution during the study period. Therefore, this study was a retrospective, exploratory, descriptive radiographic study of a modified weight-bearing metatarso-sesamoid (MS) projection, rather than a diagnostic-accuracy, comparative, or feasibility study. Methods: Between 2022 and 2024, 18 patients (16 female, 2 male; mean age 46 years, range 25–75 years) with 22 feet scheduled for HV surgery were included. Preoperative weight-bearing AP, lateral, and modified MS radiographs were evaluated. The alpha angle, sesamoid rotation angle (SRA), AOFAS tibial sesamoid grade, and the pronation/subluxation (P/S) pattern were recorded on the modified MS view. Because the alpha angle and P/S classification were originally defined on axial CT, we applied them to plain radiography as an exploratory approach. We did not validate them against a CT reference standard. Intraobserver and interobserver measurement agreement on the same existing radiographs was assessed through repeated blinded measurements by the primary observer after four weeks and through independent evaluations by a second blinded observer. We quantified reliability using ICC(2,1), unweighted kappa, and linearly weighted kappa, with 95% CIs. Technical acquisition performance was recorded. Results: On AP radiographs, IMA1–2 showed 2 mild, 15 moderate, and 5 severe deformities; HVA showed 1 normal, 11 mild, and 10 moderate cases; and Agrawal lateral sesamoid (LS) severity showed 1 mild, 20 moderate, and 1 severe case. On the modified MS view, the alpha angle ranged from 6° to 30° (mean ± SD 15.6 ± 6.6°), and the SRA from 6° to 45° (18.2 ± 8.3°). Using the CT-derived thresholds as descriptive reference labels only, alpha values were at or below 15.8° in 13 feet and above 15.8° in 9 feet, and SRA values were within the 7–18° reference range in 11 feet. AOFAS tibial sesamoid grade was 0 in 6 feet, 1 in 11, and 2 in 5. P/S patterns were P−/S− in 9 feet, P−/S+ in 4, P+/S− in 4, and P+/S+ in 5. Intraobserver ICCs were 0.996 (95% CI 0.991–0.998) for the alpha angle and 0.998 (0.994–0.999) for the SRA; interobserver ICCs were 0.988 (0.972–0.994) and 0.975 (0.947–0.981), respectively. Interobserver agreement was substantial for the P/S pattern (κ = 0.746, 95% CI 0.476–0.937) and excellent for the AOFAS grade (linear weighted κ = 0.878, 95% CI 0.663–1.000); intraobserver agreement was κ = 1.000 for both. The modified MS view provided a diagnostic image on the first acquisition in 15 of 18 patients; 3 patients required a single repeat acquisition, which was adequate in every case, and no procedure-related discomfort or intolerance was recorded. Acquisition time and radiation exposure were not recorded. Conclusions: Weight-bearing CT remains the reference standard for three-dimensional assessment. In this small cohort study, the modified MS projection could be obtained in every patient and showed high intraobserver and interobserver measurement agreement when the same existing radiographs were assessed. These findings describe measurement agreement on the same existing radiographs and the acquisition experience. Because no WBCT reference standard was available, the study cannot determine which projection reflects the underlying anatomy and provides no evidence of diagnostic accuracy, superiority over AP radiography, or clinical benefit. Standardized prospective studies with direct WBCT validation are required.

27 January 2026 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
CACahit Ancar
Cahit Ancar
AYAzad Yıldırım
Azad Yıldırım
HYHamza Yıldız
Hamza Yıldız
KDKutbettin Dinçer
Kutbettin Dinçer
MAMustafa Altıntaş
Mustafa Altıntaş
MŞMehmet Akif Şahin
Mehmet Akif Şahin
Preserving the tibial remnant of a torn anterior cruciate ligament (ACL) during reconstruction is thought to enhance graft revascularisation, proprioceptio

25 September 2026 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KDKutbettin Dinçer
Kutbettin Dinçer
MŞMehmet Akif Şahin
Mehmet Akif Şahin
Background/Objectives: Developmental dysplasia of the hip (DDH) is a common pediatric musculoskeletal disorder, and the optimal treatment approach remains controversial. This study compared open and closed reduction in terms of acetabular development, avascular necrosis (AVN) of the femoral head, and the need for subsequent pelvic osteotomy. Methods: This retrospective cohort study evaluated 75 patients (95 hips; 48 right, 47 left) treated for DDH at a tertiary referral center. We performed open reduction in 63 hips and closed reduction in 32. We performed arthrography in 50 hips (52.6%) with a positive Ortolani test to assess reduction quality. We assessed acetabular remodeling using the acetabular index (AI) at 6, 12, and 36 months postoperatively. Dislocation severity was graded using the Tönnis classification, and AVN was assessed using the Kalamchi–MacEwen criteria. Statistical analyses included chi-square tests, independent-samples t-tests, one-way ANOVAs, and Pearson correlation tests, with significance set at p < 0.05. Results: The mean age at surgery was 12.83 ± 5.13 months (range: 6–24 months), and the mean follow-up was 37.78 ± 8.07 months (range: 36–60 months). AVN was observed in 7/63 hips (11.1%) after open reduction and in 0/32 hips after closed reduction (two-sided Fisher exact test, p = 0.091). Among the seven AVN-affected hips, four were Kalamchi–MacEwen grade I, two were grade II, and one was grade III; no grade IV case was observed. Secondary pelvic osteotomy was performed in 13/63 hips (20.6%) after open reduction and 2/32 hips (6.3%) after closed reduction. AI improved during follow-up, decreasing from 38.31 ± 4.47° at 6 months to 31.59 ± 4.28° at 12 months and 23.65 ± 6.03° at 36 months. Higher Tönnis grades were associated with higher 36-month AI values (p = 0.018). Older age at surgery correlated positively with AI at 12 months (p = 0.038) and 36 months (p < 0.001). Conclusions: Open reduction was associated with higher rates of AVN and secondary pelvic osteotomy; however, treatment selection was based on reducibility and arthrographic findings, precluding causal interpretation. Older age at treatment and greater dislocation severity were associated with less favorable acetabular remodeling. Arthrography-assisted closed reduction remains a reasonable option when a stable concentric reduction is achievable, although neither method demonstrated clear superiority.